Robust Circuit Parameters Design for the CLLC-Type DC Transformer in the Hybrid AC–DC Microgrid
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
CLLC-type dc transformer (CLLC-DCT) is very popular in the hybrid ac-dc microgrid thanks to its high-power density advantage and good bidirectional power transfer capacity. In the hybrid ac/dc microgrid, the open-loop control is always utilized by the CLLC-DCT to cooperate with the bidirectional interlinking converter to realize the power and voltage conversion between the ac and dc bus. This paper first studies the circuit parameters design of the open-loop controlled CLLC-DCT with consideration of such a realistic problem: The real inductors/capacitors values are actually different with their theoretically designed values due to the operation power and temperature variation. To solve this problem, a robust circuit parameters design scheme is proposed for the CLLC-DCT in this paper. With the proposed scheme, the designed CLLC-DCT exhibits good power transmission and voltage regulation ability in the hybrid ac/dc microgrid even when its actual inductors/capacitors values vary with the practical power and temperature. The robust design method is experimentally verified in a hybrid ac/dc microgrid prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
He, P., & Khaligh, A. (2017) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2016.2630927 · Cited by 501
Li, B., Lee, F. C., Li, Q., & Liu, Z. (2017) · 2017 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2017.7931228 · Cited by 105 · cited 1×
“In the conventional CLLC-DCT applications such as electric vehicle [20] and battery charging [21], the CLLC-DCT is usually an independent power converter that regulates the target voltage/power to its reference value via a closed-loop control.”
Cited by
Extreme Fast Charging of Electric Vehicles: A Technology Overview
Tu, H., Feng, H., Srdic, S., & Lukic, S. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2958709 · Cited by 898
Khalid, M. R., Khan, I. A., Hameed, S., Asghar, M. S. J., & Ro, J. (2021) · IEEE Access · doi:10.1109/access.2021.3112189 · Cited by 353
Dong, D., Agamy, M., Bebic, J. Z., Chen, Q., & Mandrusiak, G. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2896046 · Cited by 154
Min, J., & Ordonez, M. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3033982 · Cited by 152
“However, compared with symmetric designed CLLC dc transformer applications in [18]–[20], the main concern of bidirectional charger applicants is wide battery voltage regulation.”
BackgroundMethod
Metadata
- Authors
- Huang, J., Zhang, X., Shuai, Z., Zhang, X., Wang, P., Koh, L. H., Xiao, J., & Tong, X.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2019-03
- Volume
- 66
- Issue
- 3
- Pages
- 1906-1918
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2801909766
- Cited by
- 138
- References
- 3
- FWCI
- 6.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robust Circuit Parameters Design for the CLLC-Type DC Transformer in the Hybrid AC–DC Microgrid. https://app.cochat.ai/papers/10.1109/tie.2018.2835373
- The paper
- Huang, J., Zhang, X., Shuai, Z., Zhang, X., Wang, P., Koh, L. H., Xiao, J., & Tong, X. (2019). Robust Circuit Parameters Design for the CLLC-Type DC Transformer in the Hybrid AC–DC Microgrid. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2018.2835373
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.