Impact of Inverter-Interfaced Renewable Energy Generators on Distance Protection and an Improved Scheme
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
With different structures and control strategies, inverter-interfaced renewable energy generators (IIREGs) have different fault characteristics from synchronous generators. This makes the conventional distance protection used in networks with synchronous generators not applicable for transmission lines emanating from IIREGs. Therefore, supported by the fault current analysis, operating performances of distance relays on both sides of the transmission line are unveiled. It reveals the problem that the conventional distance relay on the IIREG side has a high risk of malfunction or refusing to operate. To cope with this adaptability problem, an improved scheme based on time delay and zero-sequence impedance is proposed in this paper. To validate the operating performances of the scheme, a detailed IIREG model is built in a real-time digital simulator, and simulation tests are carried out. Apart from these, a field short-circuit test is performed in a real wind power plant to examine the practical feasibility of the proposed scheme. Both the simulation results and the field test confirm the problem of the conventional distance protection and verify the reliability of the improved scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dual current control scheme for PWM converter under unbalanced input voltage conditions
Song, H.-S., & Nam, K. (1999) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.793344 · Cited by 930 · cited 1×
“However, renewable energy sources are usually connected to the ac grid through converters, whose fault characteristics are influenced by control strategies [9], [10].”
BackgroundCentral Power Research Institute, Telukunta, V., Pradhan, J., Central Power Research Institute, Agrawal, A., Central Power Research Institute, Singh, M., Central Power Research Institute, Srivani, S. G., & R V College of Engineering (2017) · CSEE Journal of Power and Energy Systems · doi:10.17775/cseejpes.2017.00030 · Cited by 544
Technical challenges associated with the integration of wind power into power systems
Georgilakis, P. S. (2006) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2006.10.007 · Cited by 415 · cited 1×
“or light-rich regions to the load centers [5].”
BackgroundChen, Z., Wu, L., Cheng, S., Lin, P., Wu, Y., & Lin, W.-C. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.05.034 · Cited by 390 · cited 1×
“tronic technology, centralized large-scale wind farms and photovoltaic plants are being worldwide deployed [4].”
BackgroundOperational flexibility and economics of power plants in future low-carbon power systems
Brouwer, A. S., van den Broek, M., Seebregts, A., & Faaij, A. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.06.065 · Cited by 291 · cited 1×
“A S CLEAN and renewable energy power, wind and photovoltaic can significantly reduce the dependence of electricity on fossil fuels and carbon emissions from electric power plants [1]–[3].”
BackgroundJia, J., Yang, G., & Nielsen, A. H. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2682164 · Cited by 219 · cited 1×
“When other control objectives, such as suppressing active power oscillations, suppressing reactive power oscillations, and taking the flexible and semiflexible power control strategies described in [29], are adopted, a large negative-sequence component will appear in the three-phase currents after faults.”
BackgroundBlackburn, J. L., & Domin, T. J. (2006) · CRC Press eBooks · doi:10.1201/9781420017847 · Cited by 217
Singh, M. (2017) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-017-0061-1 · Cited by 109 · cited 1×
“Due to the different characteristics between renewable energy generators and synchronous generators [11], [12], the conventional protection based on fault characteristics of synchronous generators cannot meet the demand of the renewable energy system [13].”
BackgroundA novel method for adaptive distance protection of transmission line connected to wind farms
Sadeghi, H. (2012) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.06.072 · Cited by 84 · cited 1×
“As described in [16]–[18], research studies on the adaptive setting of distance relays were often based on the characteristics of doubly fed induction generators.”
BackgroundLiu, S., Bi, T., Jia, K., & Yang, Q. (2015) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2015.0003 · Cited by 39
Self-citation
Cited by
Zhang, H., Xiang, W., Lin, W., & Wen, J. (2021) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2021.000257 · Cited by 529
A Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Fan, B., Liu, T., Zhao, F., Wu, H., & Wang, X. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3227507 · Cited by 371
Pourghasem Gavgani, P., Baghbannovin, S., Mohseni-Bonab, S. M., & Kamwa, I. (2024) · Energies · doi:10.3390/en17061353 · Cited by 19
Metadata
- Authors
- Fang, Y., Jia, K., Yang, Z., Li, Y., & Bi, T.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2019-09
- Volume
- 66
- Issue
- 9
- Pages
- 7078-7088
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2898302362
- Cited by
- 205
- References
- 10
- FWCI
- 7.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.