CoChat

A Turn Fault Mitigation Strategy Based on Current Injection Technique for a Triple Three-Phase PMA SynRM

Wang, Bo, Wang, Jiabin, Griffo, Antonio, Huang, Lei · 2020 · IEEE Transactions on Industrial Electronics

The DOI matches its Crossref record; 28 of the 29 references it cites were found in a registry or an index.

Abstract

A turn-to-turn short-circuit fault usually causes excessive fault current because of very low impedance associated with a few fault turns. It should be dealt with promptly to avoid further damages to the machine, especially for a permanent magnet (PM) machine. In order to limit the turn fault current, a novel turn fault mitigation strategy based on current injection technique for a triple redundant 3 × 3-phase PM synchronous reluctance machine (PMA SynRM) is investigated in this paper. First, the flux linkage of the fault phase where the fault turns are located is estimated considering the influence of PM and currents in the healthy and fault three-phase sets. This flux linkage, including that of the fault turns, is subsequently reduced by injecting specific currents to the fault three-phase set, leading to much smaller fault current. The proposed current injection method does not affect the operation of the healthy three-phase sets that continue to produce torque. The effectiveness of the proposed method is validated by extensive finite-element (FE) simulation and experimental tests on a prototype 3 × 3-phase fault-tolerant PMA SynRM drive.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2019.2908595

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

Metadata

Authors
Wang, B., Wang, J., Griffo, A., & Huang, L.
Affiliations
  • Southeast University (CN)
  • University of Sheffield (GB)
Venue
IEEE Transactions on Industrial Electronics
Published
2020-04
Volume
67
Issue
4
Pages
2511-2522
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W2950265800
Cited by
33
References
29
Citations by year
2026: 1 · 2025: 6 · 2024: 6 · 2023: 2 · 2022: 6 · 2021: 11
FWCI
1.62
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Industrial Electronics (publishedVersion)
  • White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (acceptedVersion)
Funders
Fundamental Research Funds for the Central Universities (3216009402)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
  • Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
Keywords
turn-to-turn short circuit, fault current mitigation, current injection, fault-tolerant drives, flux linkage estimation, permanent magnet machines

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.