A Turn Fault Mitigation Strategy Based on Current Injection Technique for a Triple Three-Phase PMA SynRM
The DOI matches its Crossref record; 28 of the 29 references it cites were found in a registry or an index.
Abstract
A turn-to-turn short-circuit fault usually causes excessive fault current because of very low impedance associated with a few fault turns. It should be dealt with promptly to avoid further damages to the machine, especially for a permanent magnet (PM) machine. In order to limit the turn fault current, a novel turn fault mitigation strategy based on current injection technique for a triple redundant 3 × 3-phase PM synchronous reluctance machine (PMA SynRM) is investigated in this paper. First, the flux linkage of the fault phase where the fault turns are located is estimated considering the influence of PM and currents in the healthy and fault three-phase sets. This flux linkage, including that of the fault turns, is subsequently reduced by injecting specific currents to the fault three-phase set, leading to much smaller fault current. The proposed current injection method does not affect the operation of the healthy three-phase sets that continue to produce torque. The effectiveness of the proposed method is validated by extensive finite-element (FE) simulation and experimental tests on a prototype 3 × 3-phase fault-tolerant PMA SynRM drive.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“However, this method cannot be directly adopted to three-phase PMSM.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [327]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
Report of Large Motor Reliability Survey of Industrial and Commercial Installations, Part I
(1985) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1985.349532 · Cited by 602
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Fault-tolerant permanent magnet machinedrives
Mecrow, B. C., Jack, A. G., Haylock, J. A., & Coles, J. (1996) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19960796 · Cited by 376 · cited 3×
“Therefore, the resultant short-circuit current decreases with the increase in the number of faulted turns [2], [23].”
Increased Efficiency Versus Increased Reliability
Bonnett, A., & Yung, C. (2008) · IEEE Industry Applications Magazine · doi:10.1109/mia.2007.909802 · Cited by 359
Design and Testing of a Four-Phase Fault-Tolerant Permanent-Magnet Machine for an Engine Fuel Pump
Mecrow, B. C., Jack, A. G., Atkinson, D. J., Green, S. R., Atkinson, G. J., King, A., & Green, B. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.832074 · Cited by 252
Extension of winding function theory for nonuniform air gap in electric machinery
Faiz, J., & Tabatabaei, I. (2002) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2002.804805 · Cited by 178
Analytical Prediction of the Short-Circuit Current in Fault-Tolerant Permanent-Magnet Machines
Sun, Z., Wang, J., Howe, D., & Jewell, G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005019 · Cited by 121
Self-citationMitigation of Turn-to-Turn Faults in Fault Tolerant Permanent Magnet Synchronous Motors
Cintron-Rivera, J. G., Foster, S. N., & Strangas, E. G. (2015) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2360813 · Cited by 104
Fault Analysis of a PM Brushless DC Motor Using Finite Element Method
Dai, M., Keyhani, A., & Sebastian, T. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.841516 · Cited by 100
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“In order to limit the ITSC current, a strategy based on current injection technique was proposed for a triple redundant 3×3-phase PM synchronous reluctance machine [327].”
BackgroundMethodYepes, A. G., López, Ó., González‐Prieto, I., Duran, M. J., & Doval‐Gandoy, J. (2022) · Machines · doi:10.3390/machines10030208 · Cited by 150
Performance Improvement of Synchronous Reluctance Machines—A Review Research
Tawfiq, K. B., Ibrahim, M. N. F., El-Kholy, E. E., & Sergeant, P. (2021) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2021.3108634 · Cited by 60
Hang, J., Ding, S., Ren, X., Hu, Q., Huang, Y., Hua, W., & Wang, Q. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3073774 · Cited by 61
Integration of Interturn Fault Diagnosis and Fault-Tolerant Control for PMSM Drive System
Hang, J., Sun, W., Hu, Q., Ren, X., & Ding, S. (2021) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2021.3134821 · Cited by 58
“In [27], a mitigation strategy based on current injection is developed to reduce”
MethodHang, J., Wang, X., Li, W., & Ding, S. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3484469 · Cited by 56
“In [27], the ITSC fault mitigation strategy based on the current injection technique is proposed for a triple-redundant 3 × 3-phase permanent magnet synchronous reluctance motor to limit the fault current.”
Sun, Y., Zhao, W., Ji, J., Zheng, J., & Song, X. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3059546 · Cited by 46
“coil burned, and irreversible demagnetization [7], [8].”
Yepes, A. G., Fonseca, D. S. B., Antunes, H. R. P., López, Ó., Cardoso, A. J. M., & Doval‐Gandoy, J. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3206141 · Cited by 39
“These actions can be fixing the defective machine part or, in some cases, adequately reconfiguring the control (for eccentricity [10] or interturn [11], [12], [13], [14], [15], [16],”
BackgroundXu, Y., Zhang, Z., Jiang, Y., Huang, J., & Jiang, W. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2956399 · Cited by 34
“Literature has been reported concerning the turn-to-turn SC fault mitigation methods [17]–[21].”
BackgroundFeng, X., Wang, B., Liu, C., Zeng, J., & Wang, Z. (2023) · CES Transactions on Electrical Machines and Systems · doi:10.30941/cestems.2023.00050 · Cited by 35
Self-citationMitigation of Interturn Short-Circuits in IPMSM by Using MTPCC Control Adaptive to Fault Severity
Huang, S., Aggarwal, A., Strangas, E. G., Khoshoo, B., Li, K., & Niu, F. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3127538 · Cited by 32
Common Predictive Model for PMSM Drives With Interturn Fault Considering Torque Ripple Suppression
Li, W., Hang, J., Ding, S., & Wang, Q. (2022) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2022.3232820 · Cited by 32
Yin, Z., Sui, Y., Zheng, P., Yang, S., Zheng, Z., & Huang, J. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3084172 · Cited by 27
“Apart from the machine design view, SC FTC strategies are also studied to suppress SC current and improve postfault performances [21]–[26].”
BackgroundForstner, G., Kugi, A., & Kemmetmüller, W. (2021) · Control Engineering Practice · doi:10.1016/j.conengprac.2021.104846 · Cited by 22
A Critical Review of Fault-Tolerant Control for Multiphase PMSM Drive Systems
Liu, X., Liu, S., Fu, Z., & Ge, L. (2025) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2025.3598977 · Cited by 22
“For example, in [90], the flux linkages of the permanent magnets and those coupled by the healthy and faulted phases in the faulted winding in a nine-phase motor were first estimated.”
Geng, L., Chai, F., & Pei, Y. (2022) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2022.3177696 · Cited by 13
“current injection method is proposed [22], [23].”
Diagnosis of Interturn Short Circuit Fault in BLDCM Based on Coupled High-Frequency Signal Injection
Wang, H., Wu, Z., Zhou, F., Cao, W., Hu, C., & Lu, S. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3457950 · Cited by 11
“This type of fault can result in abnormal current flow between motor windings, which increases power loss, and the likelihood of other severe faults, and even a system breakdown [13], [14].”
BackgroundWan, Y. X., Meng, N., Jia, Y., & Zhu, L. (2022) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2022.3148108 · Cited by 11
Gan, B., Zhang, B., & Feng, G. (2021) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.23424 · Cited by 10
S., A. R., Karri, S., Nemani, S. T., Sunil Nag, P., V, Kumar, C. S., & George, K. K. (2025) · International Conference on Power Electronics Converters for Transportation and Energy Applications (PECTEA) · doi:10.1109/pectea61788.2025.11076376 · Cited by 5
“A permanent magnet-assisted synchronous reluctance motor test bed implemented a current injection technique to mitigate fault impact, allowing for real-time monitoring and control using high-frequency data acquisition systems [11].”
Gan, B., Zhang, B., Liu, Y., & Feng, G. (2021) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.23526 · Cited by 5
Zhou, Q. G., Hu, W., Wang, T., & Chu, F. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3368160 · Cited by 4
“In [32], the feature was successfully used to develop a fault current mitigation technology.”
MethodDaniar, A., Gardner, M. C., Sajadi, R., & Khan, S. A. (2024) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2024.3478213 · Cited by 3
“The authors of [20] introduced an approach to address ITSC faults in a triple redundant 3 × 3-phase PMA SynRM, employing current injection.”
Fault tolerant control of a three‐phase PMSM by limiting the heat of an inter‐turn fault
Foitzik, S., & Doppelbauer, M. (2021) · IET Electric Power Applications · doi:10.1049/elp2.12142 · Cited by 3
“A current injection technique is presented in [11].”
MethodKumar, L., Nadarajan, S., Gupta, A. K., & Nguyen, H. D. (2023) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2023.3319991 · Cited by 3
“TTSC fault-tolerant triple three-phase permanent magnet synchronous reluctance machine using current injection method based on the estimated flux linkage is presented in [25], where the redundant healthy three-phase sets produce the required rated torque for postfault operation.”
MethodIsmail, H. S., Daniar, A., & Gardner, M. C. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3605455 · Cited by 1
“Several studies have investigated current injection methods for mitigating ITSC fault currents by reducing the fl ux linkage in the shorted turn [8], [15], [16], [17], [18], [19].”
Fault Diagnosis and Adaptive Fault-Tolerant Control of Interturn Short-Circuit Fault in PMSM Drives
Zhang, Y., Wang, X., Peng, J., Kong, L., Wang, Z., & Mao, Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3645891 · Cited by 6
“Generally, the short-circuit current of PMSM can be reduced significantly by conducting field weakening and restricting the operating speed [20], [21].”
Gan, B., Zhang, B., Liu, Y., & Feng, G. (2021) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.23507 · Cited by 1
Guo, L., Wang, K., Li, F., Zhu, S., & Cao, R. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3534752 · Cited by 1
Fault Tolerant Control for PMSG with Interturn Short Fault Based on Current Residuals
Cheng, Y., Bai, J., Cai, S., Wu, F., Yang, X., & Zhou, X. (2024) · Asia-Pacific Power and Energy Engineering Conference (APPEEC) · doi:10.1109/appeec61255.2024.10922424 · Cited by 1
“In [11], a current injection based interturn fault tolerant control scheme is recommended for a three redundant 3×3 phase permanent magnet synchronous reluctance motor.”
Cheng, Q., & Song, S. (2024) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon55916.2024.10905711
“In [4] and [5], by injecting specific currents into the three phases, the short-circuit current of the faulty phase is minimized, and the healthy phase continues to generate torque.”
Fault-Tolerant Control of Interturn Short-Circuits in SPMSM by Using MTPCC
Huang, S., Su, J., Aggarwal, A., & Bernardes, J. V. (2025) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce58356.2025.11260057
“Additionally, a current injection strategy for the same topology introduced healthy-phase-derived currents into the faulty set to nullify shorted-turn flux linkage, preserving healthy-phase currents and torque [9].”
A machine learning-based classification method for SynRM faults
Rajini, V., Nagarajan, V. S., Gulbarga, M. I., Aljarbouh, A., Jassem, M., Meer, A., & Saleel, C. A. (2026) · Scientific Reports · doi:10.1038/s41598-026-42396-0
“This indirect detection mechanism makes bearing fault diagnosis more challenging in current-domain analysis 21,22 , particularly under low-load or noisy conditions, and often benefits from multi-sensor fusion approaches.”
Metadata
- Authors
- Wang, B., Wang, J., Griffo, A., & Huang, L.
- Affiliations
- Southeast University (CN)
- University of Sheffield (GB)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2020-04
- Volume
- 67
- Issue
- 4
- Pages
- 2511-2522
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2950265800
- Cited by
- 33
- References
- 29
- Citations by year
- 2026: 1 · 2025: 6 · 2024: 6 · 2023: 2 · 2022: 6 · 2021: 11
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (acceptedVersion)
- Funders
- Fundamental Research Funds for the Central Universities (3216009402)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Keywords
- turn-to-turn short circuit, fault current mitigation, current injection, fault-tolerant drives, flux linkage estimation, permanent magnet machines
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.