A Turn Fault Mitigation Strategy Based on Current Injection Technique for a Triple Three-Phase PMA SynRM
The DOI matches its Crossref record; 28 of the 29 references it cites were found in a registry or an index.
Abstract
A turn-to-turn short-circuit fault usually causes excessive fault current because of very low impedance associated with a few fault turns. It should be dealt with promptly to avoid further damages to the machine, especially for a permanent magnet (PM) machine. In order to limit the turn fault current, a novel turn fault mitigation strategy based on current injection technique for a triple redundant 3 × 3-phase PM synchronous reluctance machine (PMA SynRM) is investigated in this paper. First, the flux linkage of the fault phase where the fault turns are located is estimated considering the influence of PM and currents in the healthy and fault three-phase sets. This flux linkage, including that of the fault turns, is subsequently reduced by injecting specific currents to the fault three-phase set, leading to much smaller fault current. The proposed current injection method does not affect the operation of the healthy three-phase sets that continue to produce torque. The effectiveness of the proposed method is validated by extensive finite-element (FE) simulation and experimental tests on a prototype 3 × 3-phase fault-tolerant PMA SynRM drive.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“However, this method cannot be directly adopted to three-phase PMSM.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [327]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
Report of Large Motor Reliability Survey of Industrial and Commercial Installations, Part I
(1985) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1985.349532 · Cited by 602
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Fault-tolerant permanent magnet machinedrives
Mecrow, B. C., Jack, A. G., Haylock, J. A., & Coles, J. (1996) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19960796 · Cited by 376 · cited 3×
“Therefore, the resultant short-circuit current decreases with the increase in the number of faulted turns [2], [23].”
Increased Efficiency Versus Increased Reliability
Bonnett, A., & Yung, C. (2008) · IEEE Industry Applications Magazine · doi:10.1109/mia.2007.909802 · Cited by 359
Design and Testing of a Four-Phase Fault-Tolerant Permanent-Magnet Machine for an Engine Fuel Pump
Mecrow, B. C., Jack, A. G., Atkinson, D. J., Green, S. R., Atkinson, G. J., King, A., & Green, B. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.832074 · Cited by 252
Extension of winding function theory for nonuniform air gap in electric machinery
Faiz, J., & Tabatabaei, I. (2002) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2002.804805 · Cited by 178
Analytical Prediction of the Short-Circuit Current in Fault-Tolerant Permanent-Magnet Machines
Sun, Z., Wang, J., Howe, D., & Jewell, G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005019 · Cited by 121
Self-citationMitigation of Turn-to-Turn Faults in Fault Tolerant Permanent Magnet Synchronous Motors
Cintron-Rivera, J. G., Foster, S. N., & Strangas, E. G. (2015) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2360813 · Cited by 104
Fault Analysis of a PM Brushless DC Motor Using Finite Element Method
Dai, M., Keyhani, A., & Sebastian, T. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.841516 · Cited by 100
Analysis of PM synchronous motor drive failures during flux weakening operation
Bianchi, N., Bolognani, S., & Zigliotto, M. (2002) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.1996.548786 · Cited by 90
Nadarajan, S., Panda, S. K., Bhangu, B., & Gupta, A. K. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2535959 · Cited by 80
An evaluation of inductances of a squirrel-cage induction motor under mixed eccentric conditions
Faiz, J., Ardekanei, I. T., & Toliyat, H. A. (2003) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.811740 · Cited by 74
Experimental Assessments of a Triple Redundant Nine-Phase Fault-Tolerant PMA SynRM Drive
Wang, B., Wang, J., Griffo, A., & Sen, B. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2784368 · Cited by 74
Self-citationStator Interturn Fault Detection in Permanent-Magnet Machines Using PWM Ripple Current Measurement
Sen, B., & Wang, J. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2515560 · Cited by 63
Self-citationAn On-Line Stator Turn Fault Detection Method for Interior PM Synchronous Motor Drives
Lee, Y., & Habetler, T. G. (2007) · APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apex.2007.357610 · Cited by 60
Kim, K., Park, J.-K., Hur, J., & Kim, B.-W. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2272911 · Cited by 50
Jiang, Y., Zhang, Z., Jiang, W., Geng, W., & Huang, J. (2018) · IET Electric Power Applications · doi:10.1049/iet-epa.2017.0754 · Cited by 45
Implications of shorted turn faults in bar wound PM machines
Mitcham, A. J., Antonopoulos, G., & Cullen, J. J. A. (2004) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20040686 · Cited by 43
Welchko, B. A., Wai, J., Jahns, T. M., & Lipo, T. A. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.861313 · Cited by 42
A General Modeling Technique for a Triple Redundant 3 × 3-Phase PMA SynRM
Wang, B., Wang, J., Griffo, A., & Sen, B. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2793229 · Cited by 31
Self-citationP.M. assisted synchronous reluctance drive for minimal hybrid application
Guglielmi, P., Giraudo, G., Pellegrino, G., & Vagati, A. (2004) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2004.1348424 · Cited by 25
A fault tolerant machine drive based on permanent magnet assisted synchronous reluctance machine
Wang, B., Wang, J., Griffo, A., Sun, Z., & Chong, E. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854677 · Cited by 20
Self-citationSen, B., Wang, J., & Lazari, P. (2013) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2013.6647168 · Cited by 16
Self-citationSen, B., & Wang, J. (2014) · IET International Conference on Power Electronics, Machines and Drives (PEMD) · doi:10.1049/cp.2014.0287 · Cited by 14
Self-citationAnalytical modelling of stator turn fault in surface mounted permanent magnet machines
Sen, B., & Wang, J. (2013) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2013.6647295 · Cited by 10
Self-citationStator Inter-turn Fault Detection in SPM Machines Using PWM Ripple Current Measurement
Sen, B., & Wang, J. (2014) · IET International Conference on Power Electronics, Machines and Drives (PEMD) · doi:10.1049/cp.2014.0288 · Cited by 5
Self-citationPermanent magnet generator turn fault detection using Kalman filter technique
Wang, B., Wang, J., Griffo, A., Patel, V. I., Sun, Z., Chong, E., & Smitham, R. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855347 · Cited by 4
Self-citation
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“In order to limit the ITSC current, a strategy based on current injection technique was proposed for a triple redundant 3×3-phase PM synchronous reluctance machine [327].”
BackgroundMethodYepes, A. G., López, Ó., González‐Prieto, I., Duran, M. J., & Doval‐Gandoy, J. (2022) · Machines · doi:10.3390/machines10030208 · Cited by 150
Performance Improvement of Synchronous Reluctance Machines—A Review Research
Tawfiq, K. B., Ibrahim, M. N. F., El-Kholy, E. E., & Sergeant, P. (2021) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2021.3108634 · Cited by 60
Hang, J., Ding, S., Ren, X., Hu, Q., Huang, Y., Hua, W., & Wang, Q. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3073774 · Cited by 61
Integration of Interturn Fault Diagnosis and Fault-Tolerant Control for PMSM Drive System
Hang, J., Sun, W., Hu, Q., Ren, X., & Ding, S. (2021) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2021.3134821 · Cited by 58
“In [27], a mitigation strategy based on current injection is developed to reduce”
Method
Metadata
- Authors
- Wang, B., Wang, J., Griffo, A., & Huang, L.
- Affiliations
- Southeast University (CN)
- University of Sheffield (GB)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2020-04
- Volume
- 67
- Issue
- 4
- Pages
- 2511-2522
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2950265800
- Cited by
- 33
- References
- 29
- Citations by year
- 2026: 1 · 2025: 6 · 2024: 6 · 2023: 2 · 2022: 6 · 2021: 11
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (acceptedVersion)
- Funders
- Fundamental Research Funds for the Central Universities (3216009402)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Keywords
- turn-to-turn short circuit, fault current mitigation, current injection, fault-tolerant drives, flux linkage estimation, permanent magnet machines
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.