An Approach Towards Extreme Fast Charging Station Power Delivery for Electric Vehicles with Partial Power Processing
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
This article proposes an approach for realizing the power delivery scheme for an extreme fast charging (XFC) station that is meant to simultaneously charge multiple electric vehicles (EVs). A cascaded H-bridge converter is utilized to directly interface with the medium voltage grid while dual-active-bridge based soft-switched solid-state transformers are used to achieve galvanic isolation. The proposed approach eliminates redundant power conversion by making use of partial power rated dc-dc converters to charge the individual EVs. Partial power processing enables independent charging control over each EV, while processing only a fraction of the total battery charging power. Practical implementation schemes for the partial power charger unit are analyzed. A phase-shifted full-bridge converter-based charger is proposed. Design and control considerations for enabling multiple charging points are elucidated. Experimental results from a down-scaled laboratory test-bed are provided to validate the control aspects, functionality, and effectiveness of the proposed XFC station power delivery scheme. With a down-scaled partial power converter that is rated to handle only 27% of the battery power, an efficiency improvement of 0.6% at full-load and 1.6% at 50% load is demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2020) · Springer eBooks · doi:10.1007/978-3-030-43881-4 · Cited by 5,420
Design considerations for high-voltage high-power full-bridge zero-voltage-switched PWM converter
Sabate, J. A., Vlatkovic, V., Ridley, R. B., Lee, F. C., & Cho, B. H. (1990) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.1990.66420 · Cited by 1,015
Fundamentals of Power Electronics
(2003) · Power Engineering (Willis) · doi:10.1201/9780203913468.ch2 · Cited by 559
Classification and Comparative Evaluation of PV Panel-Integrated DC–DC Converter Concepts
Kasper, M., Bortis, D., & Kolar, J. W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2273399 · Cited by 332 · cited 2×
“A partial power converter is configured as a series element or a parallel element with the load that processes only a fraction of the total power [12].”
BackgroundMethodJung, C. (2017) · IEEE Electrification Magazine · doi:10.1109/mele.2016.2644560 · Cited by 312 · cited 1×
“Currently, there is a trend to move toward 800 V dc system in passenger vehicles to facilitate XFC [21], [22] and hence, such a system is considered for this analysis.”
BackgroundElectric Vehicle Charging Station Using a Neutral Point Clamped Converter With Bipolar DC Bus
Rivera, S., Wu, B., Kouro, S., Yaramasu, V., & Wang, J. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2348937 · Cited by 305
Vasiladiotis, M., & Rufer, A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2367237 · Cited by 275 · cited 4×
“Unlike in [5], the proposed solution offers a common low-voltage dc link, which can interface with local dc microgrids”
BackgroundMethodInfluentialUltra-fast DC-charge infrastructures for EV-mobility and future smart grids
Aggeler, D., Canales, F., Zelaya-De La Parra, H., Coccia, A., Butcher, N., & Apeldoorn, O. (2010) · 2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe) · doi:10.1109/isgteurope.2010.5638899 · Cited by 274 · cited 5×
“One full XFC charge cycle refers to the worst-case operation where 6 EVs are simultaneously getting charged for a duration of 10 min.”
BackgroundInfluentialDickerman, L., & Harrison, J. (2010) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2009.935553 · Cited by 231 · cited 1×
“Analysis indicates that the lack of electric vehicle (EV) charging infrastructure and prolonged charging time can lead to driving range anxiety [2].”
BackgroundA Generalized SOC-OCV Model for Lithium-Ion Batteries and the SOC Estimation for LNMCO Battery
Zhang, C., Jiang, J., Zhang, L., Liu, S., Wang, L., & Loh, P. (2016) · Energies · doi:10.3390/en9110900 · Cited by 213 · cited 1×
“The minimum battery pack voltage (725 V) corresponds to around 20% state of charge (SoC) while the maximum battery pack voltage (800 V) corresponds to around 80% SoC based on the LNMCO/graphite lithium ion (Li-ion) cell data provided in [23].”
Background
Cited by
Extreme Fast Charging of Electric Vehicles: A Technology Overview
Tu, H., Feng, H., Srdic, S., & Lukic, S. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2958709 · Cited by 898
“For example, in [50] and [51], different partial power dc/dc converters are proposed to interface to a common dc bus of an XFC station.”
BackgroundSafayatullah, M., Elrais, M. T., Ghosh, S., Rezaii, R., & Batarseh, I. (2022) · IEEE Access · doi:10.1109/access.2022.3166935 · Cited by 615
Advancing energy storage: The future trajectory of lithium-ion battery technologies
Hasan, M. M., Haque, R., Jahirul, M. I., Rasul, M. G., Fattah, I. M. R., Hassan, N. M. S., & Mofijur, M. (2025) · Journal of Energy Storage · doi:10.1016/j.est.2025.116511 · Cited by 446
Khalid, M. R., Khan, I. A., Hameed, S., Asghar, M. S. J., & Ro, J. (2021) · IEEE Access · doi:10.1109/access.2021.3112189 · Cited by 353
High-Efficiency SiC-Based Isolated Three-Port DC/DC Converters for Hybrid Charging Stations
Dao, N. D., Lee, D.-C., & Phan, Q. D. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2975124 · Cited by 174
“converter, and DAB converter [25], [26].”
Metadata
- Authors
- Iyer, V. M., Gulur, S., Gohil, G., & Bhattacharya, S.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2020-10
- Volume
- 67
- Issue
- 10
- Pages
- 8076-8087
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2981111681
- Cited by
- 237
- References
- 19
- FWCI
- 7.75
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.