A Triaxial Accelerometer Calibration Method Using a Mathematical Model
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
This paper presents a new triaxial accelerometer calibration method using a mathematical model of six calibration parameters: three gain factors and three biases. The fundamental principle of the proposed calibration method is that the sum of the triaxial accelerometer outputs is equal to the gravity vector when the accelerometer is stationary. The proposed method requires the triaxial accelerometer to be placed in six different tilt angles to estimate the six calibration parameters. Since the mathematical model of the calibration parameters is nonlinear, an iterative method is used. The results are verified via simulations by comparing the estimated gain factors and biases with the true gain factors and biases. The simulation results confirm that the proposed method is applicable in extreme cases where the gain factor is 1000 V/(m/s2) and the bias is ±100 V, as well as the cases where the gain factor is 0.001 V/(m/s2) and the bias is 0 V. The proposed calibration method is also experimentally tested with two different triaxial accelerometers, and the results are validated using a mechanical inclinometer. The experimental results show that the proposed method can accurately estimate gain factors and biases even when the initial guesses are not close to the true values. In addition, the proposed method has a low computational cost because the calculation is simple, and the iterative method usually converges within three iteration steps. The error sources of the experiments are discussed in this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new multi-position calibration method for MEMS inertial navigation systems
Syed, Z. F., Aggarwal, P., Goodall, C., Niu, X., & El-Sheimy, N. (2007) · Measurement Science and Technology · doi:10.1088/0957-0233/18/7/016 · Cited by 386 · cited 2×
“gain factors and biases, the method in [17] includes a calibration”
MethodInclination measurement of human movement using a 3-D accelerometer with autocalibration
Luinge, H. J., & Veltink, P. H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.822759 · Cited by 307 · cited 1×
“T RIAXIAL accelerometers are used in various applications, such as inertial navigation systems (INSs) [1], [2] and inclinometers [3]–[5].”
MethodProcedure for in-use calibration of triaxial accelerometers in medical applications
Lötters, J. C., Schipper, J., Veltink, P. H., Olthuis, W., & Bergveld, P. (1998) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(98)00049-1 · Cited by 203
Procedure for effortless in-field calibration of three-axial rate gyro and accelerometers
Ferraris, F., Grimaldi, U., & Parvis, M. (1995) · PORTO@Iris · Cited by 163
Inertial navigation system aided by aircraft dynamics
Koifman, M., & Bar‐Itzhack, I. Y. (1999) · IEEE Transactions on Control Systems Technology · doi:10.1109/87.772164 · Cited by 126 · cited 1×
“T RIAXIAL accelerometers are used in various applications, such as inertial navigation systems (INSs) [1], [2] and inclinometers [3]–[5].”
MethodBody position can be monitored in 3D using miniature accelerometers and earth-magnetic field sensors
Kemp, B., Janssen, A. J. M. W., & van der Kamp, B. (1998) · Electroencephalography and Clinical Neurophysiology/Electromyography and Motor Control · doi:10.1016/s0924-980x(98)00053-8 · Cited by 124 · cited 1×
“T RIAXIAL accelerometers are used in various applications, such as inertial navigation systems (INSs) [1], [2] and inclinometers [3]–[5].”
MethodInitial calibration of an inertial measurement unit using an optical position tracking system
Kim, A., & Golnaraghi, M. F. (2004) · IEEE/ION Position Location and Navigation Symposium · doi:10.1109/plans.2004.1308980 · Cited by 109 · cited 1×
“sensor [14], [15], can accurately compute the gain factors and”
MethodEstimating orientation with gyroscopes and accelerometers
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7612 · Cited by 103
Estimation of orientation with gyroscopes and accelerometers
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (2003) · doi:10.1109/iembs.1999.803999 · Cited by 75
Renk, E. L., Rizzo, M., Collins, W., Lee, F., & Bernstein, D. S. (2005) · IEEE Control Systems · doi:10.1109/mcs.2005.1550155 · Cited by 51 · cited 1×
“using an external device, such as actuator [12], [13] or position”
Method
Cited by
Analyses of Triaxial Accelerometer Calibration Algorithms
Sipos, M., Paces, P., Rohac, J., & Novacek, P. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2167319 · Cited by 145
Metadata
- Authors
- Won, S. P., & Golnaraghi, F.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2010-08
- Volume
- 59
- Issue
- 8
- Pages
- 2144-2153
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2120356803
- Cited by
- 163
- References
- 12
- FWCI
- 13.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.