Arterial blood pressure estimation from local pulse wave velocity using dual-element photoplethysmograph probe

Nabeel, P.M., Karthik, Srinivasa, Joseph, Jayaraj, Sivaprakasam, Mohanasankar·2018·IEEE Transactions on Instrumentation and Measurement

Abstract

An arterial compliance, dual-element photoplethysmograph probe for local pulse wave velocity (PWV) measurement was developed. Initially, the experimental validation study was performed on 25 young volunteers (age =24.5 ± 4 years). Local PWV was assessed from a small section (23 mm) of the carotid artery. The prototype device demonstrated its capability of measuring reliable, repeatable, and reproducible carotid local PWV. Further, in 15 healthy male volunteers (age = 22.25 ± 3.5 years), carotid local PWV and brachial blood pressure (BP) were continuously recorded during their postexercise recovery period. Local PWV followed the changes in arterial BP parameters. The group average correlation coefficients (r) of local PWV versus BP parameters were between 0.772 ± 0.033 and 0.934 ± 0.028. In a population of 50 patients (normotensive and hypertensive) aged 24-80 years, local PWV-BP correlations were investigated. Local PWV tended to follow the diastolic BP (DBP; r = 0.82) and mean arterial pressure (r = 0.83) better than systolic BP (SBP; r = 0.69). It was significantly inferior in tracking pulse pressure values (r = 0.35). Cuffless estimation of arterial pressure was also performed on the same patients using measured carotid local PWV with best-case calibrations. Local PWV yielded good DBP prediction than SBP prediction. Statistically, significant correlation (r = 0.79) and a root-mean-square error of 5.26 mmHg versus reference brachial DBP were achieved. The introduced technique has a potential for short- or long-term noninvasive, cuffless monitoring of BP parameters from superficial arteries.

Integrity signals

Registry

Crossref · 10.1109/tim.2018.2800539

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • PTT, used to determine PWV and estimate blood pressure without a cuff, requires extraction of the time delay from two PPG waveforms or from an ECG and PPG waveform.

    “Additionally, some parameters in the literature such as pulse transit time (PTT), which is used to determine pulse wave velocity (PWV) and estimate blood pressure without a cuff, requires extraction of the time delay from two PPG waveforms or from an ECG and PPG waveform [31,32].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Nabeel, P. M., Karthik, S., Joseph, J., & Sivaprakasam, M.
Affiliations
Indian Institute of Technology Madras (IN)
Venue
IEEE Transactions on Instrumentation and Measurement
Published
2018-06
Volume
67
Issue
6
Pages
1399-1408
ISSN
  • 0018-9456 (ISSN-L)
  • 1557-9662
OpenAlex
W2790723868
Cited by
72
References
30
Citations by year
2026: 2 · 2025: 9 · 2024: 13 · 2023: 6 · 2022: 6 · 2021: 11 · 2020: 13 · 2019: 8 · 2018: 4
FWCI
3.60
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Instrumentation and Measurement (publishedVersion)
Funders
Science and Engineering Research Board, Department of Science and Technology, Government of India
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
arterial blood pressure estimation, carotid artery, cuffless blood pressure measurement, non-invasive blood pressure measurement, arterial compliance, post-exercise recovery, hypertension, pulse pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review