Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 214

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Non-invasive continuous-time glucose monitoring system using a chipless printable sensor based on split ring microwave resonators

Open access
Baghelani, Masoud, Abbasi, Zahra, Daneshmand, Mojgan, Light, Peter E. · 2020 · Scientific Reports

Abstract

This paper reports a highly sensitive, non-invasive sensor for real-time glucose monitoring from interstitial fluid. The structure is comprised of a chip-less tag sensor which may be taped over the patient’s skin and a reader, that can be embedded in a smartwatch. The tag sensor is energized through the established electromagnetic coupling between the tag and the reader and its frequency response is reflected on the spectrum of the reader in the same manner. The tag sensor consumes zero power as there is no requirement for any active readout or communication circuitry on the tag side. When measuring changes in glucose concentrations within saline replicating interstitial fluid, the sensor was able to detect glucose with an accuracy of ~ 1 mM/l over a physiological range of glucose concentrations with 38 kHz of the resonance frequency shift. This high sensitivity is attained as a result of the proposed new design and extended field concentration on the tag. The impact of some of the possible interferences on the response of the sensor’s performance was also investigated. Variations in electrolyte concentrations within the test samples have a negligible effect on the response of the sensor unless these variations are supra-physiologically large.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-020-69547-1

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Research works printed but not linked: 50

  1. Scully, T. Diabetes in numbers. Nature 485(7398), S2 (2012). · DOI · Paper page
  2. Godsland, I. F. & Walton, C. Maximizing the success rate of minimal model insulin sensitivity measurement in humans: The importance of basal glucose levels. Clin. Sci. 101(1), 1–9 (2001). · doi:10.1042/cs20000250
  3. Mclachlan, K., Jenkins, A. & O’neal, D. The role of continuous glucose monitoring in clinical decision-making in diabetes in pregnancy. Aust. NZ. J. Obstet. Gyn. 47(3), 186–190 (2007). · DOI · Paper page
  4. Lin, T., Gal, A., Mayzel, Y., Horman, K. & Bahartan, K. Non-invasive glucose monitoring: A review of challenges and recent advances. Curr. Trends Biomed. Eng. Biosci. 6, 1–8 (2017).
  5. Burt, M. G., Roberts, G. W., Aguilar-Loza, N. R. & Stranks, S. N. Brief report: Comparison of continuous glucose monitoring and finger-prick blood glucose levels in hospitalized patients administered basal-bolus insulin. Diabetes Technol. 15(3), 241–245 (2013). · DOI
  6. Boyd, R., Leigh, B. & Stuart, P. Capillary versus venous bedside blood glucose estimations. Emerg. Med. J. 22(3), 177–179 (2005). · DOI
  7. Wang, G. & Mintchev, M. P. Development of wearable semi-invasive blood sampling devices for continuous glucose monitoring: A survey. Engineering 5(5), 42 (2013). · DOI
  8. Cobelli, C., Renard, E. & Kovatchev, B. Artificial pancreas: Past, present, future. Diabetes 60(11), 2672–2682 (2011). · DOI · Paper page
  9. Gingras, V. et al. Impact of erroneous meal insulin bolus with dual-hormone artificial pancreas using a simplified bolus strategy-A randomized controlled trial. Sci. Rep.-UK 8(1), 2621 (2018). · DOI
  10. Albisser, A. M. et al. Clinical control of diabetes by the artificial pancreas. Diabetes 23(5), 397–404 (1974). · DOI · Paper page
  11. Phillip, M. et al. Nocturnal glucose control with an artificial pancreas at a diabetes camp. N. Engl. J. Med. 368(9), 824–833 (2013). · DOI · Paper page
  12. Tze, W. J., Wong, F. C., Chen, L. M. & O’young, S. Implantable artificial endocrine pancreas unit used to restore normoglycaemia in the diabetic rat. Nature 264(5585), 466 (1976). · DOI
  13. Yadav, J., Rani, A., Singh, V. & Murari, B. M. Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy. Biomed. Signal Process. 18, 214–227 (2015). · DOI · Paper page
  14. Goodarzi, M. & Saeys, W. Selection of the most informative near infrared spectroscopy wavebands for continuous glucose monitoring in human serum. Talanta 146, 155–165 (2016). · DOI
  15. Spegazzini, N. et al. Spectroscopic approach for dynamic bioanalyte tracking with minimal concentration information. Sci. Rep.-UK 4, 7013 (2014). · DOI
  16. Kuroda, M. et al. Effects of daily glucose fluctuations on the healing response to everolimus-eluting stent implantation as assessed using continuous glucose monitoring and optical coherence tomography. Cardiovasc. Diabetol. 15(1), 79 (2016). · DOI
  17. Sim, J. Y., Ahn, C. G., Jeong, E. J. & Kim, B. K. In vivo microscopic photoacoustic spectroscopy for non-invasive glucose monitoring invulnerable to skin secretion products. Sci. Rep.-UK 8(1), 1059 (2018). · DOI · Paper page
  18. Kim, J., Campbell, A. S. & Wang, J. Wearable non-invasive epidermal glucose sensors: A review. Talanta 177, 163–170 (2018). · DOI · Paper page
  19. Malchoff, C. D., Shoukri, K., Landau, J. I. & Buchert, J. M. A novel noninvasive blood glucose monitor. Diabetes Care 25(12), 2268–2275 (2002). · DOI
  20. De Castro, L. F. et al. Salivary diagnostics on paper microfluidic devices and their use as wearable sensors for glucose monitoring. Anal. Bioanal. Chem. 411(19), 4919–4928 (2019). · DOI · Paper page
  21. Karyakin, A. A. et al. Non-invasive monitoring of diabetes through analysis of the exhaled breath condensate (aerosol). Electrochem. Commun. 83, 81–84 (2017). · DOI
  22. Karpova, E. V. et al. Noninvasive diabetes monitoring through continuous analysis of sweat using flow-through glucose biosensor. Anal. Chem. 91(6), 3778–3783 (2019). · DOI · Paper page
  23. Baghelani, M., Abbasi, Z. & Daneshmand, M. Noncontact high sensitivity chipless tag microwave resonator for bitumen concentration measurement at high temperatures. Fuel 265, 116916 (2020). · doi:10.1016/j.fuel.2019.116916
  24. Abbasi, Z., Shariaty, P., Nosrati, M., Hashisho, Z. & Daneshmand, M. Dual-band microwave circuits for selective binary gas sensing system. IEEE T. Microw. Theory. 67(10), 4206–4219 (2019). · DOI
  25. Zarifi, M. H., Sadabadi, H., Hejazi, S. H., Daneshmand, M. & Sanati-Nezhad, A. Noncontact and nonintrusive microwave-microfluidic flow sensor for energy and biomedical engineering. Sci. Rep.-UK 8(1), 139 (2018). · DOI · Paper page
  26. Liu, W., Yang, X., Niu, Y. & Sun, H. Improve planar multiple split-ring resonator sensor for microwave detection applications. Sens. Actuator A- Phys. 297, 111542 (2019). · doi:10.1016/j.sna.2019.111542
  27. Tsai, T. T. et al. High throughput and label-free particle sensor based on microwave resonators. Sens. Actuator A- Phys. 285, 652–658 (2019). · doi:10.1016/j.sna.2018.12.008
  28. Benlamri, M. et al. Planar microwave resonator with electrodeposited ZnO thin film for ultraviolet detection. Semicond. Sci. Technol. 35(2), 025003 (2019). · doi:10.1088/1361-6641/ab5924
  29. Jha, A. K., Delmonte, N., Lamecki, A., Mrozowski, M. & Bozzi, M. Design of microwave-based angular displacement sensor. IEEE Microw. Wirel. Co. 29(4), 306–308 (2019). · doi:10.1109/lmwc.2019.2899490
  30. Nosrati, M., Abbasi, Z., Baghelani, M., Bhadra, S. & Daneshmand, M. Locally strong-coupled microwave resonator using PEMC boundary for distant sensing applications. IEEE Trans. Microw. Theory. 67(10), 4130–4139 (2019). · doi:10.1109/tmtt.2019.2931555
  31. Camli, B. et al. A microwave ring resonator based glucose sensor. Proc. Eng. 168, 465–468 (2016). · doi:10.1016/j.proeng.2016.11.127
  32. Chretiennot, T., Dubuc, D. & Grenier, K. Microwave-based microfluidic sensor for non-destructive and quantitative glucose monitoring in aqueous solution. Sensors 16(10), 1733 (2016). · doi:10.3390/s16101733
  33. Bahar, A. A. M. et al. Real time microwave biochemical sensor based on circular SIW approach for aqueous dielectric detection. Sci. Rep.-UK 9(1), 5467 (2019). · doi:10.1038/s41598-019-41702-3
  34. Choi, H. et al. Design and in vitro interference test of microwave noninvasive blood glucose monitoring sensor. IEEE Trans. Microw. Theory. 63(10), 3016–3025 (2015). · DOI · Paper page
  35. Kim, N. Y. et al. Rapid, sensitive, and reusable detection of glucose by a robust radiofrequency integrated passive device biosensor chip. Sci. Rep.-UK 5, 7807 (2015). · DOI · Paper page
  36. Sharafadinzadeh, N., Abdolrazzaghi, M. & Daneshmand, M. Investigation on planar microwave sensors with enhanced sensitivity from microfluidic integration. Sens. Actuator A- Phys. 301, 111752 (2020). · DOI
  37. Kapilevich, B. & Litvak, B. Optimized microwave sensor for online concentration measurements of binary liquid mixtures. IEEE Sens. J. 11(10), 2611–2616 (2011). · doi:10.1109/jsen.2011.2149517
  38. Juan, C. G. et al. Concentration measurement of microliter-volume water-glucose solutions using q factor of microwave sensors. IEEE Trans. Instrum. Meas. 68(7), 2621–2634 (2019). · DOI · Paper page
  39. Turgul, V. & Kale, I. Permittivity extraction of glucose solutions through artificial neural networks and non-invasive microwave glucose sensing. Sens. Actuator A- Phys. 277, 65–72 (2018). · DOI
  40. Chakyar, S. P., Simon, K. S., Bindu, C., Andrews, J. & Joseph, V. P. Complex permittivity measurement using metamaterial split ring resonators. J. Appl. Phys. 121(5), 054101 (2017). · doi:10.1063/1.4975111
  41. Aezinia, F. & Bahreyni, B. An interface circuit with wide dynamic range for differential capacitive sensing applications. IEEE Trans. Circuits II. 60(11), 766–770 (2013).
  42. Yang, C. L., Lee, C. S., Chen, K. W. & Chen, K. Z. Noncontact measurement of complex permittivity and thickness by using planar resonators. IEEE Trans. Microw. Theory 64(1), 247–257 (2015). · doi:10.1109/tmtt.2015.2503764
  43. Pu, Z. et al. A flexible electrochemical glucose sensor with composite nanostructured surface of the working electrode. Sens. Actuator B- Chem. 230, 801–809 (2016). · DOI
  44. Haxha, S. & Jhoja, J. Optical based noninvasive glucose monitoring sensor prototype. IEEE Photonics J. 8(6), 1–11 (2016). · DOI
  45. Kumari, R., Patel, P. N. & Yadav, R. An ENG resonator-based microwave sensor for the characterization of aqueous glucose. J. Phys. D Appl. Phys. 51(7), 075601 (2018). · doi:10.1088/1361-6463/aaa5c5
  46. Camli, B. et al. Cost-effective, microstrip antenna driven ring resonator microwave biosensor for biospecific detection of glucose. IEEE J. Sel. Top. Quant. 23(2), 404–409 (2017). · DOI
  47. Govind, G. & Akhtar, M. J. Metamaterial-inspired microwave microfluidic sensor for glucose monitoring in aqueous solutions. IEEE Sens. J. 19(24), 11900–11907 (2019). · doi:10.1109/jsen.2019.2938853
  48. Diem, K. & Lentner, C. Blood-Inorganic Substances. Documents Geigy Scientific Tables 565 (Ciba-Geigy Limited, Basle, 1970).
  49. Qing, X., Chen, Z.N., See, T.S.P., Goh, C.K. & Chiam, T.M., Characterization of RF transmission in human body. In 2010 IEEE Antennas and Propagation Society International Symposium, 1–4 (2010).
  50. Peyman, A., Rezazadeh, A. A. & Gabriel, C. Changes in the dielectric properties of rat tissue as a function of age at microwave frequencies. Phys. Med. 47(12), 2187 (2002).

Cited by

See all 214

Metadata

Authors
Baghelani, M., Abbasi, Z., Daneshmand, M., & Light, P. E.
Venue
Scientific Reports
Published
2020-07-31
Volume
10
Issue
1
Pages
12980-12980
ISSN
2045-2322 (ISSN-L)
OpenAlex
W3046853010
Cited by
214
References
9
FWCI
9.03
Type
journal article
Language
en
Open access
gold
Licence
Funders
  • Alberta Diabetes Institute
  • Natural Sciences and Engineering Research Council of Canada
  • FESRI

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Non-invasive continuous-time glucose monitoring system using a chipless printable sensor based on split ring microwave resonators. https://app.cochat.ai/papers/10.1038/s41598-020-69547-1
The paper
Baghelani, M., Abbasi, Z., Daneshmand, M., & Light, P. E. (2020). Non-invasive continuous-time glucose monitoring system using a chipless printable sensor based on split ring microwave resonators. Scientific Reports. https://doi.org/10.1038/s41598-020-69547-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.