The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Non-invasive continuous-time glucose monitoring system using a chipless printable sensor based on split ring microwave resonators
Open accessAbstract
This paper reports a highly sensitive, non-invasive sensor for real-time glucose monitoring from interstitial fluid. The structure is comprised of a chip-less tag sensor which may be taped over the patient’s skin and a reader, that can be embedded in a smartwatch. The tag sensor is energized through the established electromagnetic coupling between the tag and the reader and its frequency response is reflected on the spectrum of the reader in the same manner. The tag sensor consumes zero power as there is no requirement for any active readout or communication circuitry on the tag side. When measuring changes in glucose concentrations within saline replicating interstitial fluid, the sensor was able to detect glucose with an accuracy of ~ 1 mM/l over a physiological range of glucose concentrations with 38 kHz of the resonance frequency shift. This high sensitivity is attained as a result of the proposed new design and extended field concentration on the tag. The impact of some of the possible interferences on the response of the sensor’s performance was also investigated. Variations in electrolyte concentrations within the test samples have a negligible effect on the response of the sensor unless these variations are supra-physiologically large.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In situ click chemistry generation of cyclooxygenase-2 inhibitors
Bhardwaj, A., Kaur, J., Wuest, M., & Wuest, F. (2017) · Nature Communications · doi:10.1038/s41467-016-0009-6 · Cited by 7,448
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, J., Kim, M., Lee, M.-S., Kim, K., Ji, S., Kim, Y.-T., Park, J., Na, K., Bae, K.-H., Kyun Kim, H., et al. (2017) · Nature Communications · doi:10.1038/ncomms14997 · Cited by 951
A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
El-Khatib, F. H., Russell, S. J., Nathan, D. M., Sutherlin, R. G., & Damiano, E. R. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000619 · Cited by 403
Tierney, M. J., Tamada, J. A., Potts, R. O., Jovanovic, L., & Garg, S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00189-0 · Cited by 390
Lipani, L., Dupont, B. G. R., Doungmene, F., Marken, F., Tyrrell, R. M., Guy, R. H., & Ilie, A. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0112-4 · Cited by 340
Eyeglasses-based tear biosensing system: Non-invasive detection of alcohol, vitamins and glucose
Sempionatto, J. R., Brazaca, L. C., García-Carmona, L., Bolat, G., Campbell, A. S., Martin, A., Tang, G., Shah, R., Mishra, R. K., Kim, J., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.04.058 · Cited by 315
Simultaneous lancet-free monitoring of alcohol and glucose from low-volumes of perspired human sweat
Bhide, A., Muthukumar, S., Saini, A., & Prasad, S. (2018) · Scientific Reports · doi:10.1038/s41598-018-24543-4 · Cited by 76
Research works printed but not linked: 50
- Scully, T. Diabetes in numbers. Nature 485(7398), S2 (2012). · DOI · Paper page
- Godsland, I. F. & Walton, C. Maximizing the success rate of minimal model insulin sensitivity measurement in humans: The importance of basal glucose levels. Clin. Sci. 101(1), 1–9 (2001). · doi:10.1042/cs20000250
- Mclachlan, K., Jenkins, A. & O’neal, D. The role of continuous glucose monitoring in clinical decision-making in diabetes in pregnancy. Aust. NZ. J. Obstet. Gyn. 47(3), 186–190 (2007). · DOI · Paper page
- Lin, T., Gal, A., Mayzel, Y., Horman, K. & Bahartan, K. Non-invasive glucose monitoring: A review of challenges and recent advances. Curr. Trends Biomed. Eng. Biosci. 6, 1–8 (2017).
- Burt, M. G., Roberts, G. W., Aguilar-Loza, N. R. & Stranks, S. N. Brief report: Comparison of continuous glucose monitoring and finger-prick blood glucose levels in hospitalized patients administered basal-bolus insulin. Diabetes Technol. 15(3), 241–245 (2013). · DOI
- Boyd, R., Leigh, B. & Stuart, P. Capillary versus venous bedside blood glucose estimations. Emerg. Med. J. 22(3), 177–179 (2005). · DOI
- Wang, G. & Mintchev, M. P. Development of wearable semi-invasive blood sampling devices for continuous glucose monitoring: A survey. Engineering 5(5), 42 (2013). · DOI
- Cobelli, C., Renard, E. & Kovatchev, B. Artificial pancreas: Past, present, future. Diabetes 60(11), 2672–2682 (2011). · DOI · Paper page
- Gingras, V. et al. Impact of erroneous meal insulin bolus with dual-hormone artificial pancreas using a simplified bolus strategy-A randomized controlled trial. Sci. Rep.-UK 8(1), 2621 (2018). · DOI
- Albisser, A. M. et al. Clinical control of diabetes by the artificial pancreas. Diabetes 23(5), 397–404 (1974). · DOI · Paper page
- Phillip, M. et al. Nocturnal glucose control with an artificial pancreas at a diabetes camp. N. Engl. J. Med. 368(9), 824–833 (2013). · DOI · Paper page
- Tze, W. J., Wong, F. C., Chen, L. M. & O’young, S. Implantable artificial endocrine pancreas unit used to restore normoglycaemia in the diabetic rat. Nature 264(5585), 466 (1976). · DOI
- Yadav, J., Rani, A., Singh, V. & Murari, B. M. Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy. Biomed. Signal Process. 18, 214–227 (2015). · DOI · Paper page
- Goodarzi, M. & Saeys, W. Selection of the most informative near infrared spectroscopy wavebands for continuous glucose monitoring in human serum. Talanta 146, 155–165 (2016). · DOI
- Spegazzini, N. et al. Spectroscopic approach for dynamic bioanalyte tracking with minimal concentration information. Sci. Rep.-UK 4, 7013 (2014). · DOI
- Kuroda, M. et al. Effects of daily glucose fluctuations on the healing response to everolimus-eluting stent implantation as assessed using continuous glucose monitoring and optical coherence tomography. Cardiovasc. Diabetol. 15(1), 79 (2016). · DOI
- Sim, J. Y., Ahn, C. G., Jeong, E. J. & Kim, B. K. In vivo microscopic photoacoustic spectroscopy for non-invasive glucose monitoring invulnerable to skin secretion products. Sci. Rep.-UK 8(1), 1059 (2018). · DOI · Paper page
- Kim, J., Campbell, A. S. & Wang, J. Wearable non-invasive epidermal glucose sensors: A review. Talanta 177, 163–170 (2018). · DOI · Paper page
- Malchoff, C. D., Shoukri, K., Landau, J. I. & Buchert, J. M. A novel noninvasive blood glucose monitor. Diabetes Care 25(12), 2268–2275 (2002). · DOI
- De Castro, L. F. et al. Salivary diagnostics on paper microfluidic devices and their use as wearable sensors for glucose monitoring. Anal. Bioanal. Chem. 411(19), 4919–4928 (2019). · DOI · Paper page
- Karyakin, A. A. et al. Non-invasive monitoring of diabetes through analysis of the exhaled breath condensate (aerosol). Electrochem. Commun. 83, 81–84 (2017). · DOI
- Karpova, E. V. et al. Noninvasive diabetes monitoring through continuous analysis of sweat using flow-through glucose biosensor. Anal. Chem. 91(6), 3778–3783 (2019). · DOI · Paper page
- Baghelani, M., Abbasi, Z. & Daneshmand, M. Noncontact high sensitivity chipless tag microwave resonator for bitumen concentration measurement at high temperatures. Fuel 265, 116916 (2020). · doi:10.1016/j.fuel.2019.116916
- Abbasi, Z., Shariaty, P., Nosrati, M., Hashisho, Z. & Daneshmand, M. Dual-band microwave circuits for selective binary gas sensing system. IEEE T. Microw. Theory. 67(10), 4206–4219 (2019). · DOI
- Zarifi, M. H., Sadabadi, H., Hejazi, S. H., Daneshmand, M. & Sanati-Nezhad, A. Noncontact and nonintrusive microwave-microfluidic flow sensor for energy and biomedical engineering. Sci. Rep.-UK 8(1), 139 (2018). · DOI · Paper page
- Liu, W., Yang, X., Niu, Y. & Sun, H. Improve planar multiple split-ring resonator sensor for microwave detection applications. Sens. Actuator A- Phys. 297, 111542 (2019). · doi:10.1016/j.sna.2019.111542
- Tsai, T. T. et al. High throughput and label-free particle sensor based on microwave resonators. Sens. Actuator A- Phys. 285, 652–658 (2019). · doi:10.1016/j.sna.2018.12.008
- Benlamri, M. et al. Planar microwave resonator with electrodeposited ZnO thin film for ultraviolet detection. Semicond. Sci. Technol. 35(2), 025003 (2019). · doi:10.1088/1361-6641/ab5924
- Jha, A. K., Delmonte, N., Lamecki, A., Mrozowski, M. & Bozzi, M. Design of microwave-based angular displacement sensor. IEEE Microw. Wirel. Co. 29(4), 306–308 (2019). · doi:10.1109/lmwc.2019.2899490
- Nosrati, M., Abbasi, Z., Baghelani, M., Bhadra, S. & Daneshmand, M. Locally strong-coupled microwave resonator using PEMC boundary for distant sensing applications. IEEE Trans. Microw. Theory. 67(10), 4130–4139 (2019). · doi:10.1109/tmtt.2019.2931555
- Camli, B. et al. A microwave ring resonator based glucose sensor. Proc. Eng. 168, 465–468 (2016). · doi:10.1016/j.proeng.2016.11.127
- Chretiennot, T., Dubuc, D. & Grenier, K. Microwave-based microfluidic sensor for non-destructive and quantitative glucose monitoring in aqueous solution. Sensors 16(10), 1733 (2016). · doi:10.3390/s16101733
- Bahar, A. A. M. et al. Real time microwave biochemical sensor based on circular SIW approach for aqueous dielectric detection. Sci. Rep.-UK 9(1), 5467 (2019). · doi:10.1038/s41598-019-41702-3
- Choi, H. et al. Design and in vitro interference test of microwave noninvasive blood glucose monitoring sensor. IEEE Trans. Microw. Theory. 63(10), 3016–3025 (2015). · DOI · Paper page
- Kim, N. Y. et al. Rapid, sensitive, and reusable detection of glucose by a robust radiofrequency integrated passive device biosensor chip. Sci. Rep.-UK 5, 7807 (2015). · DOI · Paper page
- Sharafadinzadeh, N., Abdolrazzaghi, M. & Daneshmand, M. Investigation on planar microwave sensors with enhanced sensitivity from microfluidic integration. Sens. Actuator A- Phys. 301, 111752 (2020). · DOI
- Kapilevich, B. & Litvak, B. Optimized microwave sensor for online concentration measurements of binary liquid mixtures. IEEE Sens. J. 11(10), 2611–2616 (2011). · doi:10.1109/jsen.2011.2149517
- Juan, C. G. et al. Concentration measurement of microliter-volume water-glucose solutions using q factor of microwave sensors. IEEE Trans. Instrum. Meas. 68(7), 2621–2634 (2019). · DOI · Paper page
- Turgul, V. & Kale, I. Permittivity extraction of glucose solutions through artificial neural networks and non-invasive microwave glucose sensing. Sens. Actuator A- Phys. 277, 65–72 (2018). · DOI
- Chakyar, S. P., Simon, K. S., Bindu, C., Andrews, J. & Joseph, V. P. Complex permittivity measurement using metamaterial split ring resonators. J. Appl. Phys. 121(5), 054101 (2017). · doi:10.1063/1.4975111
- Aezinia, F. & Bahreyni, B. An interface circuit with wide dynamic range for differential capacitive sensing applications. IEEE Trans. Circuits II. 60(11), 766–770 (2013).
- Yang, C. L., Lee, C. S., Chen, K. W. & Chen, K. Z. Noncontact measurement of complex permittivity and thickness by using planar resonators. IEEE Trans. Microw. Theory 64(1), 247–257 (2015). · doi:10.1109/tmtt.2015.2503764
- Pu, Z. et al. A flexible electrochemical glucose sensor with composite nanostructured surface of the working electrode. Sens. Actuator B- Chem. 230, 801–809 (2016). · DOI
- Haxha, S. & Jhoja, J. Optical based noninvasive glucose monitoring sensor prototype. IEEE Photonics J. 8(6), 1–11 (2016). · DOI
- Kumari, R., Patel, P. N. & Yadav, R. An ENG resonator-based microwave sensor for the characterization of aqueous glucose. J. Phys. D Appl. Phys. 51(7), 075601 (2018). · doi:10.1088/1361-6463/aaa5c5
- Camli, B. et al. Cost-effective, microstrip antenna driven ring resonator microwave biosensor for biospecific detection of glucose. IEEE J. Sel. Top. Quant. 23(2), 404–409 (2017). · DOI
- Govind, G. & Akhtar, M. J. Metamaterial-inspired microwave microfluidic sensor for glucose monitoring in aqueous solutions. IEEE Sens. J. 19(24), 11900–11907 (2019). · doi:10.1109/jsen.2019.2938853
- Diem, K. & Lentner, C. Blood-Inorganic Substances. Documents Geigy Scientific Tables 565 (Ciba-Geigy Limited, Basle, 1970).
- Qing, X., Chen, Z.N., See, T.S.P., Goh, C.K. & Chiam, T.M., Characterization of RF transmission in human body. In 2010 IEEE Antennas and Propagation Society International Symposium, 1–4 (2010).
- Peyman, A., Rezazadeh, A. A. & Gabriel, C. Changes in the dielectric properties of rat tissue as a function of age at microwave frequencies. Phys. Med. 47(12), 2187 (2002).
Cited by
Lee, I., Probst, D., Klonoff, D., & Sode, K. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113054 · Cited by 288
Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210
Metadata
- Authors
- Baghelani, M., Abbasi, Z., Daneshmand, M., & Light, P. E.
- Venue
- Scientific Reports
- Published
- 2020-07-31
- Volume
- 10
- Issue
- 1
- Pages
- 12980-12980
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3046853010
- Cited by
- 214
- References
- 9
- FWCI
- 9.03
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Funders
- Alberta Diabetes Institute
- Natural Sciences and Engineering Research Council of Canada
- FESRI
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-invasive continuous-time glucose monitoring system using a chipless printable sensor based on split ring microwave resonators. https://app.cochat.ai/papers/10.1038/s41598-020-69547-1
- The paper
- Baghelani, M., Abbasi, Z., Daneshmand, M., & Light, P. E. (2020). Non-invasive continuous-time glucose monitoring system using a chipless printable sensor based on split ring microwave resonators. Scientific Reports. https://doi.org/10.1038/s41598-020-69547-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.