An Automatic Graph-Based Approach for Artery/Vein Classification in Retinal Images
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The classification of retinal vessels into artery/vein (A/V) is an important phase for automating the detection of vascular changes, and for the calculation of characteristic signs associated with several systemic diseases such as diabetes, hypertension, and other cardiovascular conditions. This paper presents an automatic approach for A/V classification based on the analysis of a graph extracted from the retinal vasculature. The proposed method classifies the entire vascular tree deciding on the type of each intersection point (graph nodes) and assigning one of two labels to each vessel segment (graph links). Final classification of a vessel segment as A/V is performed through the combination of the graph-based labeling results with a set of intensity features. The results of this proposed method are compared with manual labeling for three public databases. Accuracy values of 88.3%, 87.4%, and 89.8% are obtained for the images of the INSPIRE-AVR, DRIVE, and VICAVR databases, respectively. These results demonstrate that our method outperforms recent approaches for A/V classification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hubbard, L. D., Brothers, R. J., King, W. N., Clegg, L. X., Klein, R., Cooper, L. S., Sharrett, A. R., Davis, M. D., & Cai, J. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90525-0 · Cited by 1,184 · cited 1×
“Among other image processing operations, the estimation of AVR requires vessel segmentation, accurate vessel width measurement, and artery/vein (A/V) classification [9], [10].”
MethodMendonca, A. M., & Campilho, A. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879955 · Cited by 921 · cited 1×
“There are visual and geometrical features that enable discrimination between veins and arteries; several methods have explored these properties for A/V classification [11]–[17].”
Self-citationRevised formulas for summarizing retinal vessel diameters
Knudtson, M. D., Lee, K. E., Hubbard, L. D., Wong, T. Y., Klein, R., & Klein, B. E. K. (2003) · Current Eye Research · doi:10.1076/ceyr.27.3.143.16049 · Cited by 872 · cited 2×
“Among other image processing operations, the estimation of AVR requires vessel segmentation, accurate vessel width measurement, and artery/vein (A/V) classification [9], [10].”
BackgroundMethodRetinal image analysis: Concepts, applications and potential
Patton, N., Aslam, T. M., MacGillivray, T., Deary, I. J., Dhillon, B., Eikelboom, R. H., Yogesan, K., & Constable, I. J. (2006) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2005.07.001 · Cited by 641 · cited 1×
“Another advantage is the possibility to perform automated screening for pathological conditions, such as diabetic retinopathy, in order to reduce the workload required of trained manual graders [1].”
BackgroundParallel thinning with two-subiteration algorithms
Guo, Z., & Hall, R. W. (1989) · Communications of the ACM · doi:10.1145/62065.62074 · Cited by 451 · cited 1×
“A bifurcation point is an intersection point where a vessel bifurcates to narrower parts.”
BackgroundRetinal Vascular Caliber: Systemic, Environmental, and Genetic Associations
Sun, C., Wang, J. J., Mackey, D. A., & Wong, T. Y. (2009) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2008.10.003 · Cited by 413 · cited 1×
“The AVR value can also be an indicator of other diseases, like diabetic retinopathy and retinopathy of prematurity [8].”
BackgroundLuminosity and contrast normalization in retinal images
Foracchia, M., Grisan, E., & Ruggeri, A. (2005) · Medical Image Analysis · doi:10.1016/j.media.2004.07.001 · Cited by 322 · cited 1×
“[26], which normalizes both luminosity and contrast based on a model of the observed image.”
BackgroundRetinal vascular tree morphology: a semi-automatic quantification
Martinez-Perez, M. E., Highes, A. D., Stanton, A. V., Thorn, S. A., Chapman, N., Bharath, A. A., & Parker, K. H. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.800789 · Cited by 241 · cited 3×
“vascular tree is possible, and has been used in some methods to analyze the vessel tree and classify the vessels [11], [12].”
BackgroundMethodAutomated Measurement of the Arteriolar-to-Venular Width Ratio in Digital Color Fundus Photographs
Niemeijer, M., Xu, X., Dumitrescu, A. V., Gupta, P., van Ginneken, B., Folk, J. C., & Abramoff, M. D. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2159619 · Cited by 188 · cited 4×
“Some of these features were used previously in [13], [21].”
BackgroundMethodInfluentialRetinal microvascular abnormalities and cognitive decline: The ARIC 14-year follow-up study
Lesage, S. R., Mosley, T. H., Wong, T. Y., Szklo, M., Knopman, D. S., Catellier, D., Cole, S. R., Klein, R., Coresh, J., Coker, L. H., et al. (2009) · Neurology · doi:10.1212/wnl.0b013e3181b78436 · Cited by 141
Retinal vascular changes and diabetic retinopathy
Nguyen, T. T., & Wong, T. Y. (2009) · Current Diabetes Reports · doi:10.1007/s11892-009-0043-4 · Cited by 117 · cited 1×
“at early stages [2], as well as vessel diameter alterations [3].”
BackgroundSeparation of the retinal vascular graph in arteries and veins based upon structural knowledge
Rothaus, K., Jiang, X., & Rhiem, P. (2008) · Image and Vision Computing · doi:10.1016/j.imavis.2008.02.013 · Cited by 106 · cited 4×
“[12], which describes a rule-based algorithm to propagate the vessel labels as either artery or vein throughout the vascular tree.”
BackgroundMethodInfluentialRetinal Fundus Image Registration via Vascular Structure Graph Matching
Deng, K., Tian, J., Zheng, J., Zhang, X., Dai, X., & Xu, M. G. (2010) · International Journal of Biomedical Imaging · doi:10.1155/2010/906067 · Cited by 82 · cited 1×
“In recent years, graphs have emerged as a unified representation for image analysis, and graph-based methods have been used for retinal vessel segmentation [18], retinal image registration [19], and retinal vessel classification [12].”
MethodRetinal Hemodynamics in Early Diabetic Macular Edema
Guan, K., Hudson, C. D., Wong, T. Y., Kisilevsky, M., Nrusimhadevara, R. K., Lam, W., Mandelcorn, M. S., Devenyi, R. G., & Flanagan, J. G. (2006) · Diabetes · doi:10.2337/diabetes.55.03.06.db05-0937 · Cited by 76 · cited 2×
“at early stages [2], as well as vessel diameter alterations [3].”
BackgroundAutomatic classification of retinal vessels into arteries and veins
Niemeijer, M., van Ginneken, B., & Abràmoff, M. D. (2009) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.813826 · Cited by 70
Estrada, R. G., Tomasi, C., Cabrera, M. T., Wallace, D. K., Freedman, S. F., & Farsiu, S. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000327 · Cited by 43 · cited 1×
“In recent years, graphs have emerged as a unified representation for image analysis, and graph-based methods have been used for retinal vessel segmentation [18], retinal image registration [19], and retinal vessel classification [12].”
MethodRetinal Vessel Analysis Reproducibility in Assessing Cardiovascular Disease
Neubauer, A. S., Lüdtke, M., Haritoglou, C., Priglinger, S., & Kampik, A. (2008) · Optometry and Vision Science · doi:10.1097/opx.0b013e318169284c · Cited by 28 · cited 1×
“Changes in retinal blood vessels, such as significant dilatation and elongation of main arteries, veins, and their branches [3], [4], are also frequently associated with hypertension and other cardiovascular pathologies.”
BackgroundThe retinal arteriole to venule ratio: informative or deceptive?
Cheung, N., & Wong, T. Y. (2007) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-006-0486-0 · Cited by 12
Cited by
Applications of deep learning in fundus images: A review
Li, T., Bo, W., Hu, C., Kang, H., Liu, H., Wang, K., & Fu, H. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.101971 · Cited by 396
Few-Shot Class-Incremental Learning for Retinal Disease Recognition
Zhang, J., Zhao, P., Zhao, Y., Li, C., & Hu, D. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3457915 · Cited by 23
“Existing vision-based Computer-assisted Diagnosis (CAD) for retinal diseases can be broadly divided into two categories: traditional methods [10], [14], [15], [16] and Deep Learning (DL)-based vision methods [17], [18], [19], [20].”
Metadata
- Authors
- Dashtbozorg, B., Mendonca, A. M., & Campilho, A.
- Venue
- IEEE Transactions on Image Processing
- Published
- 2014-03
- Volume
- 23
- Issue
- 3
- Pages
- 1073-1083
- ISSN
- 1057-7149 (ISSN-L)
- 1941-0042
- OpenAlex
- W2117935664
- Cited by
- 207
- References
- 18
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.