Assessment of Tremor Activity in the Parkinson’s Disease Using a Set of Wearable Sensors
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Tremor is the most common motor disorder of Parkinson's disease (PD) and consequently its detection plays a crucial role in the management and treatment of PD patients. The current diagnosis procedure is based on subject-dependent clinical assessment, which has a difficulty in capturing subtle tremor features. In this paper, an automated method for both resting and action/postural tremor assessment is proposed using a set of accelerometers mounted on different patient's body segments. The estimation of tremor type (resting/action postural) and severity is based on features extracted from the acquired signals and hidden Markov models. The method is evaluated using data collected from 23 subjects (18 PD patients and 5 control subjects). The obtained results verified that the proposed method successfully: 1) quantifies tremor severity with 87 % accuracy, 2) discriminates resting from postural tremor, and 3) discriminates tremor from other Parkinsonian motor symptoms during daily activities.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Related works on the characteristics of tremor have been reported, in which amplitude and frequency parameters were proved to be significantly different between the PD patients and healthy controls [33].”
From Detection and Quantification of Resting Tremor in Parkinson's Disease Using Long-Term Acceleration Data (2021) · cites this paper as [33]
In the citing paper
“87% for tremors [3]”
From Wearability Assessment of a Wearable System for Parkinson’s Disease Remote Monitoring Based on a Body Area Network of Sensors (2014) · cites this paper as [3]
In the citing paper
“This system, called PERFORM, is based on a Body Area Network (BAN) of sensors which has already been validated both from the technical and clinical point for view.”
From Wearability Assessment of a Wearable System for Parkinson’s Disease Remote Monitoring Based on a Body Area Network of Sensors (2014) · cites this paper as [3]
Citations
Cites
A tutorial on hidden Markov models and selected applications in speech recognition
Rabiner, L. R. (1989) · Proceedings of the IEEE · doi:10.1109/5.18626 · Cited by 22,743 · cited 1×
“The output distribution is considered as a multivariate Gaussian distribution for each state P (x|Si) ∝ N(x;μi,Σi), where μi is the mean of observation under the i state and Σi the covariance [29].”
Artificial intelligence: A modern approach
Nilsson, N. J. (1996) · Artificial Intelligence · doi:10.1016/0004-3702(96)00007-0 · Cited by 10,583
Wrappers for feature subset selection
Kohavi, R., & John, G. H. (1997) · Artificial Intelligence · doi:10.1016/s0004-3702(97)00043-x · Cited by 8,947 · cited 1×
“classifier (Wrapper method [34]) is selected, which makes use of the best-first search algorithm [35].”
MethodParkinson's disease: clinical features and diagnosis
Jankovic, J. (2008) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.131045 · Cited by 5,720 · cited 4×
“ered a difficult task even by experts [2], [11].”
InfluentialAn introduction to hidden Markov models
Rabiner, L., & Juang, B. (1986) · IEEE ASSP Magazine · doi:10.1109/massp.1986.1165342 · Cited by 4,775 · cited 1×
“After training the HMM using a training dataset, the most probable state for a new sequence of observation is given by the forward–backward algorithm [30], [31].”
MethodThe bayes net toolbox for matlab
Murphy, K. (2001) · Cited by 1,014
Monitoring Motor Fluctuations in Patients With Parkinson's Disease Using Wearable Sensors
Patel, S., Lorincz, K., Hughes, R., Huggins, N., Growdon, J., Standaert, D., Akay, M., Dy, J., Welsh, M., & Bonato, P. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033471 · Cited by 623
Detection of posture and motion by accelerometry: a validation study in ambulatory monitoring
Foerster, F., Smeja, M., & Fahrenberg, J. (1999) · Computers in Human Behavior · doi:10.1016/s0747-5632(99)00037-0 · Cited by 480 · cited 1×
“There are several works which use body fixed sensors (BFS), such as accelerometers, to recognize posture or specific activities [6]–[10].”
BackgroundAssessment of physical activity: a critical appraisal
Westerterp, K. R. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1000-2 · Cited by 459
Activity Recognition of Assembly Tasks Using Body-Worn Microphones and Accelerometers
Ward, J. A., Lukowicz, P., Troster, G., & Starner, T. E. (2006) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2006.197 · Cited by 431 · cited 1×
“There are several works which use body fixed sensors (BFS), such as accelerometers, to recognize posture or specific activities [6]–[10].”
Background
Research works printed but not linked: 1
- zwartjes, 2010, Development of a system for measurement and analysis of tremor using a three-axis accelerometer, IEEE Trans Biomed Eng, 57, 2779
Cited by
Items 201–259 of 259
Hepp, D. H., OCRAN, K. W., Szanto, A., van Hilten, J. J., Exadaktylos, V., & Weijer, R. H. A. (2025) · npj Parkinson s Disease · doi:10.1038/s41531-025-01163-0 · Cited by 2
Cancela, J., Pastorino, M., & Arredondo, M. T. (2017) · IGI Global eBooks · doi:10.4018/978-1-5225-3158-6.ch050 · Cited by 2
Parkinson’s Disease Detection Through Inertial Signals and Posture Insights
Gil-Martín, M., Esteban-Romero, S., Fernández-Martínez, F., & San-Segundo, R. (2024) · International Conference on Agents and Artificial Intelligence (ICAART) · doi:10.5220/0012451100003636 · Cited by 2
“As for tremor detection algorithms, previous works have used a wide variety of machine learning algorithms, such as decision trees (Garcia-Magarino et al., 2016), random forests, hidden Markov models (Rigas et al., 2012), and neural networks (Hathaliya et al., 2022).”
BackgroundMethodA frame work for classifying physiological tremor variants employing principal component analysis
Krishna Prasad, S. J., Priyanka, D., & Talasila, V. (2014) · International Conference on Circuits, Control, Communication and Computing (I4C) · doi:10.1109/cimca.2014.7057784 · Cited by 2
Τριπολίτη, Ε. (2012) · doi:10.12681/eadd/26803 · Cited by 2
Decision support system for assessment of patients with neurodegenerative disorders
Bobic, V. N. (2021) · National Repository of Dissertations in Serbia · Cited by 2
Essential tremor evaluation system with Eval-net method via accelerometer signal
Pan, J., Liu, S., & Ni, Q. (2019) · IEEE International Conference on Service Operations and Logistics, and Informatics (SOLI) · doi:10.1109/soli48380.2019.8955003 · Cited by 1
“Although these rating scales are proved reliable and have shown clinical utility, their results are subjective and limited by the short-term observations [12] [13].”
BackgroundMachine Learning Techniques for Automated Tremor Detection in the Presence of External Stressors
M, V. K., & Talasila, V. (2022) · International Journal of Circuits Systems and Signal Processing · doi:10.46300/9106.2022.16.69 · Cited by 1
Wearing sensors inside and outside of the human body for the early detection of diseases
Zheng, Y., Jiang, Y., Luo, N., Ding, X., Zhang, Y., & Poon, C. C. Y. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819246-7.00003-6 · Cited by 1
A Novel Approach to Parkinson's Disease Progression Evaluation Using Convolutional Neural Networks
Zineddine, M. (2022) · International Journal of Software Innovation · doi:10.4018/ijsi.315655 · Cited by 1
State-of-the-Art: Wearable Devices and Deep Learning Techniques for Parkinson’s Disease
Channa, A., & Popescu, N. (2023) · SpringerBriefs in computer science · doi:10.1007/978-3-031-45003-7_2 · Cited by 1
Psathas, A., Tsoulos, I. G., Γιαννακέας, Ν., Tzallas, A. T., & Charilogis, V. (2025) · Bioengineering · doi:10.3390/bioengineering12121318 · Cited by 1
Self-citationSakib, M., Khanom, S., Nahadi, T. M., Mithu, A. M., Ahmed, N., Islam, M., Sarker, T., Chisty, N., Ahad, A., Hossain, M. M., et al. (2025) · Biomedical Engineering Letters · doi:10.1007/s13534-025-00526-z · Cited by 1
Wang, X., Peng, X., Xu, Z., Xu, M., Yang, Y., Zhou, M., Zhao, Z., Yue, P., & Yang, P. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3648564 · Cited by 1
“Although recent studies have identified certain activities relevant for evaluating specific PD motor symptoms, analysing PD symptoms in isolation has proven insufficient for accurately assessing overall disease severity [16], [17], [18], [19], [20], [21]. iii) ML Model Estimation.”
Ukasi, S., Hajra, S., Kim, H. J., Sriphan, S., Pongampai, S., Charoonsuk, T., & Vittayakorn, N. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.71380 · Cited by 1
An Intelligent Identification Model for Classifying Trembling Patterns of Parkinson’s Disease
Huang, Y., & Chuang, C.-H. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-41009-8_23 · Cited by 1
“[1] embedded a set of accelerometers on different parts of the body to measure tremor.”
BackgroundAhlrichs, C. (2015) · Cited by 1
Human daily activity recognition based on online sequential extreme learning machine
Song, Y., Liu, Z., & Wang, J. (2016) · World Congress on Intelligent Control and Automation · doi:10.1109/wcica.2016.7578572 · Cited by 1
Gavas, R. D., Mazumder, O., & Sinha, A. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176062 · Cited by 1
“Frequency distribution and frequency related features are commonly used to characterize PD tremor signal [20], [21].”
MethodLima, V., Vieira, M. F., Pereira, A. A., & Andrade, A. D. O. (2022) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-030-70601-2_51 · Cited by 1
Classification Algorithms for Analyzing Parkinson's Disease Patient
Escamilla-Luna, O., Wister, M. A., & Hernández-Torruco, J. (2022) · International Conference on Software, Telecommunications and Computer Networks (SoftCOM) · doi:10.23919/softcom55329.2022.9911391 · Cited by 1
Deep Learning Models for Parkinson’s Disease Severity Evaluation
Channa, A., & Popescu, N. (2023) · SpringerBriefs in computer science · doi:10.1007/978-3-031-45003-7_4 · Cited by 1
Patient diaries in movement disorders
Vizcarra, J. A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-99494-1.00010-1 · Cited by 1
Caland, L. M. Q. (2015) · RIUnB Institutional Repository (University of Brasília) · doi:10.26512/2015.07.d.19180 · Cited by 1
Li, M. H. G. (2017) · TSpace (University of Toronto) · Cited by 1
A unified algorithm framework for quality control of sensor data for behavioural clinimetric testingPreprint
Badawy, R., Raykov, Y. P., & Little, M. A. (2017) · arXiv (Cornell University) · doi:10.48550/arxiv.1711.07557 · Cited by 1
“or portable and wearable sensors [10, 11, 12], eliminates much of the subjective bias of clinical expert symptom measurement, while also allowing for remote, long-term monitoring of”
BackgroundCorrelating the Effect of Dynamic Variability in the Sensor Environment on Sensor Design
Bhushan, P. (2021) · FIU - Digital Commons (Florida International University) · doi:10.25148/etd.fidc009698 · Cited by 1
Development of a system of acquisition and movement analysis : application on Parkinson's disease
Jalloul, N. (2016) · theses.fr (ABES) · doi:10.70675/2331b8bbz3715z48d3za398z02a615581a5a · Cited by 1
Support system to help Parkinson's patients read books
Bravo, F. R. P. (2015) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Quantitative Assessment of Tremor in PD Using a Wearable System on Both Hands
Lee, H., Kim, S., Kim, H., Jeon, H., Park, H.-Y., Jung, Y., Kim, J., Jeon, B., & Park, K. (2014) · Journal of Biomedical Engineering Research · doi:10.9718/jber.2014.35.4.81
Cancela, J., Pastorino, M., & Arredondo, M. T. (2015) · Advances in medical diagnosis, treatment, and care (AMDTC) book series · doi:10.4018/978-1-4666-8828-5.ch023
Accelerometric Detection of Intentional Movements in the Presence of Dyskinesia
Villada, M. C. (2015) · TSpace (University of Toronto)
ON SHOE WEARABLE SENSORS FOR DETECTING FOOT NEUROPATHY
Crispino, J. J., & Joice, C. S. (2014)
Zheng, X. (2019) · UPM Digital Archive (Technical University of Madrid) · doi:10.20868/upm.thesis.55328
Çalışan, M., & Talu, M. F. (2021) · Türk doğa ve fen dergisi :/Türk doğa ve fen dergisi · doi:10.46810/tdfd.881205
“proposed an automated method for both rest and motion/vibration assessment using accelerometers attached to different parts of the Parkinson's patient's body [9].”
MethodDiagnosis of Hand Tremor from EMG Sensors
AL-Mutairi, M. M., Rao, K. P., & Mehedi, I. M. (2020) · Journal of Technological Science & Engineering (JTSE) · doi:10.5281/zenodo.3940856
Cancela, J., Pastorino, M., & Arredondo, M. T. (2018) · IGI Global eBooks · doi:10.4018/978-1-5225-5484-4.ch064
de Querétaro, U. A., Aguilera, S. A. V., Ramírez, C. Á., de Querétaro, U. A., Sanchez, J. C. S., de Querétaro, U. A., Pérez, G. G., & de Querétaro, U. A. (2018) · Memorias del Congreso Nacional de Ingeniería Biomédica · doi:10.24254/cnib.18.24
System for Non-Contact Diagnostics of Tremor
Melnik, O. V., Nikiforov, M. B., & Novikov, S. V. (2023) · Systems and Technologies of the Digital HealthCare (STDH) · doi:10.1109/stdh59314.2023.10491046
“To date, various methods are used to determine tremor, such as: • electromyography [5, 6]; • kinematic methods (accelerometry, gyroscopy) [7]; • tremor detection using video technologies and image recognition [8, 9]; Electromyography is a method of indirect analysis of tremor: during the study, not…”
MethodTECHNOLOGY-BASED EVALUATION IN PARKINSONISM
Balki, S., Nacar, E., Özkan, R. S., & Karakurt, M. (2024) · Cumhuriyet Tıp Dergisi/Cumhuriyet Üniversitesi Tıp Fakültesi dergisi · doi:10.7197/cmj.1512299
Site, A., Lohan, E. S., & Nurmi, J. (2025) · IEEE Access · doi:10.1109/access.2025.3591270
Classification of Parkinson’s Disease Using Machine Learning Techniques
Dekka, S., Raju, K. N., Sai, D. M., Pallavi, M. S., & Sambana, B. (2025) · Springer proceedings in mathematics & statistics · doi:10.1007/978-3-031-51342-8_3
Multimodal Quantification of Postural Tremor
Rathod, O. P., Baid, A., Sethi, K., & Ramu, S. P. (2025) · Springer eBooks · doi:10.1007/978-3-031-92854-3_32
Khalil, R. M. (2025) · University Libraries (University of Maryland) · doi:10.13016/ustd-0cfo
Lima, V. D. C., & Andrade, A. D. O. (2020) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.4130003
Design and realization of a device for tremor measurement
Tržil, P., & Tržil, P. (2020) · Czech Technical University Digital Library (Czech Technical University in Prague)
Avtomatsko ocenjevanje testa tapkanja s prsti pri bolnikih s Parkinsonovo boleznijo
Zupanič, M. (2024) · Repository of the University of Ljubljana (University of Ljubljana)
Development and validation of patient-friendly dexterity marker in multiple sclerosis
Gopal, A. (2023) · eScholarship (California Digital Library)
Belić, M. (2023) · National Repository of Dissertations in Serbia
Shahriar Zawad, M. R. (2025) · ScholarSpace (University of Hawaii at Manoa)
Correa, M., Samadani, A., de Holanda, L. J., Corky, Y., & Chau, T. T. (2026) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2026.103126
Virbel-Fleischman, C. (2021) · theses.fr (ABES) · doi:10.70675/21583008z772az4c86z822dza5cca46513d5
Artificial Intelligence in Neurodegenerative Disorders
Rittman, T. (2026) · Wiley eBooks · doi:10.1002/9781394278886.ch07
Advancing Flexible Pressure Sensors for Next‐Generation Medical Monitoring
Su, C., Gao, X., Wang, R., Yang, S., & Sun, Y. (2026) · Advanced Sensor Research · doi:10.1002/adsr.70163
“…reveal exponential growth in both direct medical costs (emergency care, rehabilitation) and indirect expenditures (long-term care) associated with PD-related falls, a financial burden exacerbated by polypharmacy regimens and comorbid management demands during advanced disease stages [ 169 ].”
Reddy, G. C., Tirumala, A., Brindha, A., Arjunan, S. P., Rebello, A., & Anantha, S. K. (2026) · IEEE Access · doi:10.1109/access.2026.3726124
Modelling and Correcting the Effects of Tremor on Touchscreen Interaction
Dunlop, M. D., & MacKenzie, I. S. (2026) · Sensors · doi:10.3390/s26185981
Analysis of Speech Algorithms in Disease affected Voice Patterns
Karunanithi., D., & Rodrigues, P. (2014) · International Journal of Computer Sciences and Engineering
UTILIZING DIGITAL BIOMARKERS FOR THE MONITORING AND MANAGEMENT OF PARKINSON DISEASE
Kanellos, F. S., Tsamis, K. I., Chatzistefanidis, D., Κωστίκης, Ν., & Κονιτσιώτης, Σ. (2024) · ΑΡΧΕΙΑ ΚΛΙΝΙΚΗΣ ΝΕΥΡΟΛΟΓΙΑΣ
Lozano, K., Lozano, R., Hernandez, C., Martinez, M. E., & Ventura, A. (2019) · ScholarWorks @ UTRGV (The University of Texas Rio Grande Valley)
Metadata
- Authors
- Rigas, G., Tzallas, A. T., Tsipouras, M. G., Bougia, P., Tripoliti, E. E., Baga, D., Fotiadis, D. I., Tsouli, S. G., & Konitsiotis, S.
- Affiliations
- University of Ioannina (GR)
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2012-05
- Volume
- 16
- Issue
- 3
- Pages
- 478-487
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W2159209410
- Cited by
- 241
- References
- 34
- Citations by year
- 2026: 5 · 2025: 13 · 2024: 17 · 2023: 19 · 2022: 22 · 2021: 27 · 2020: 18 · 2019: 35 · 2018: 17 · 2017: 12 · 2016: 19 · 2015: 9 · 2014: 15 · 2013: 11 · 2012: 2
- FWCI
- 12.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Information Technology in Biomedicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Health Sciences › Medicine › Clinical Neurology › Parkinson's Disease Mechanisms and Treatments
- Keywords
- Parkinson's disease, tremor assessment, wearable sensors, accelerometer, resting tremor, postural tremor, hidden Markov models, parkinsonian motor symptoms
- MeSH terms
- Aged, Algorithms, Clothing, Humans, Markov Chains, Middle Aged, Movement, Parkinson Disease, Posture, Tremor, Case-Control Studies, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.