Assessment of Tremor Activity in the Parkinson’s Disease Using a Set of Wearable Sensors
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Tremor is the most common motor disorder of Parkinson's disease (PD) and consequently its detection plays a crucial role in the management and treatment of PD patients. The current diagnosis procedure is based on subject-dependent clinical assessment, which has a difficulty in capturing subtle tremor features. In this paper, an automated method for both resting and action/postural tremor assessment is proposed using a set of accelerometers mounted on different patient's body segments. The estimation of tremor type (resting/action postural) and severity is based on features extracted from the acquired signals and hidden Markov models. The method is evaluated using data collected from 23 subjects (18 PD patients and 5 control subjects). The obtained results verified that the proposed method successfully: 1) quantifies tremor severity with 87 % accuracy, 2) discriminates resting from postural tremor, and 3) discriminates tremor from other Parkinsonian motor symptoms during daily activities.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Related works on the characteristics of tremor have been reported, in which amplitude and frequency parameters were proved to be significantly different between the PD patients and healthy controls [33].”
From Detection and Quantification of Resting Tremor in Parkinson's Disease Using Long-Term Acceleration Data (2021) · cites this paper as [33]
In the citing paper
“87% for tremors [3]”
From Wearability Assessment of a Wearable System for Parkinson’s Disease Remote Monitoring Based on a Body Area Network of Sensors (2014) · cites this paper as [3]
In the citing paper
“This system, called PERFORM, is based on a Body Area Network (BAN) of sensors which has already been validated both from the technical and clinical point for view.”
From Wearability Assessment of a Wearable System for Parkinson’s Disease Remote Monitoring Based on a Body Area Network of Sensors (2014) · cites this paper as [3]
Citations
Cites
A tutorial on hidden Markov models and selected applications in speech recognition
Rabiner, L. R. (1989) · Proceedings of the IEEE · doi:10.1109/5.18626 · Cited by 22,743 · cited 1×
“The output distribution is considered as a multivariate Gaussian distribution for each state P (x|Si) ∝ N(x;μi,Σi), where μi is the mean of observation under the i state and Σi the covariance [29].”
Artificial intelligence: A modern approach
Nilsson, N. J. (1996) · Artificial Intelligence · doi:10.1016/0004-3702(96)00007-0 · Cited by 10,583
Wrappers for feature subset selection
Kohavi, R., & John, G. H. (1997) · Artificial Intelligence · doi:10.1016/s0004-3702(97)00043-x · Cited by 8,947 · cited 1×
“classifier (Wrapper method [34]) is selected, which makes use of the best-first search algorithm [35].”
MethodParkinson's disease: clinical features and diagnosis
Jankovic, J. (2008) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.131045 · Cited by 5,720 · cited 4×
“ered a difficult task even by experts [2], [11].”
InfluentialAn introduction to hidden Markov models
Rabiner, L., & Juang, B. (1986) · IEEE ASSP Magazine · doi:10.1109/massp.1986.1165342 · Cited by 4,775 · cited 1×
“After training the HMM using a training dataset, the most probable state for a new sequence of observation is given by the forward–backward algorithm [30], [31].”
MethodThe bayes net toolbox for matlab
Murphy, K. (2001) · Cited by 1,014
Monitoring Motor Fluctuations in Patients With Parkinson's Disease Using Wearable Sensors
Patel, S., Lorincz, K., Hughes, R., Huggins, N., Growdon, J., Standaert, D., Akay, M., Dy, J., Welsh, M., & Bonato, P. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033471 · Cited by 623
Detection of posture and motion by accelerometry: a validation study in ambulatory monitoring
Foerster, F., Smeja, M., & Fahrenberg, J. (1999) · Computers in Human Behavior · doi:10.1016/s0747-5632(99)00037-0 · Cited by 480 · cited 1×
“There are several works which use body fixed sensors (BFS), such as accelerometers, to recognize posture or specific activities [6]–[10].”
BackgroundAssessment of physical activity: a critical appraisal
Westerterp, K. R. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1000-2 · Cited by 459
Activity Recognition of Assembly Tasks Using Body-Worn Microphones and Accelerometers
Ward, J. A., Lukowicz, P., Troster, G., & Starner, T. E. (2006) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2006.197 · Cited by 431 · cited 1×
“There are several works which use body fixed sensors (BFS), such as accelerometers, to recognize posture or specific activities [6]–[10].”
Background
Research works printed but not linked: 1
- zwartjes, 2010, Development of a system for measurement and analysis of tremor using a three-axis accelerometer, IEEE Trans Biomed Eng, 57, 2779
Cited by
Items 101–200 of 259
Crowe, C., Sica, M., Kenny, L., O’Flynn, B., Mueller, D. S., Timmons, S., Barton, J. J., & Tedesco, S. A. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3477003 · Cited by 19
“…and kinematics-based algorithms on inertial sensor data can indeed identify the three cardinal symptoms of PD: tremor [36], [39], [40], [41], [42], [43], [44], [45], bradykinesia [36], [39], [44], [45], [46], [47], [48], [49], [50], [51], [52], and dyskinesia [45], [50], [51], [52], [53], [54],…”
MethodInfluentialIs "Frequency Distribution" Enough to Detect Tremor in PD Patients Using a Wrist Worn Accelerometer?
Ahlrichs, C., & Samà, A. (2014) · International Conference on Pervasive Computing Technologies for Healthcare · doi:10.4108/icst.pervasivehealth.2014.254928 · Cited by 19
“Further commonly employed features are Shannon’ information features [4, 8, 9, 18], signal entropy [4, 8], as well as first and second-order statistics [8].”
BackgroundMethodInfluentialLin, C., Wu, J., Hsu, J., Chen, P.-Y., Pai, N., & Lai, H. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3103803 · Cited by 19
Lones, M. A., Alty, J., Duggan-Carter, P., Turner, A. J., Jamieson, D. R. S., & Smith, S. L. (2014) · Genetic and Evolutionary Computation Conference Companion (GECCO Companion) · doi:10.1145/2598394.2609852 · Cited by 19
“raw acceleration values and Fourier coe cients), in comparison to the use of neural networks and higher-level features (such as signal energy and spectral powers over frequency ranges) in comparable studies [9, 6, 17, 15].”
Channa, A., Cramariuc, O. T., Memon, M., Popescu, N., Mammone, N., & Ruggeri, G. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.955464 · Cited by 18
Review and Analysis of Patients’ Body Language From an Artificial Intelligence Perspective
Turaev, S., Al-Dabet, S., Babu, A., Rustamov, Z., Rustamov, J., Zaki, N., Mohamad, M. S., & Loo, C. K. (2023) · IEEE Access · doi:10.1109/access.2023.3287788 · Cited by 18
“Paper [53] proposes an automated resting and action/postural tremor assessment using a set of accelerometers mounted on different patient body segments.”
MethodIntelligent IoT Anklets for Monitoring the Assessment of Parkinson’s Diseases
Zhao, Y., Liu, Y., Lu, W., Li, J., Shan, P., Lian, C., Wang, X., Fu, C., Ma, C., & Wang, Y. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3331277 · Cited by 18
TremorSense: Tremor Detection for Parkinson's Disease Using Convolutional Neural Network
Sun, M., Watson, A., Blackwell, G. G., Jung, W., Wang, S., Koltermann, K., Helm, N., Zhou, G., Cloud, L. J., & Pretzer‐Aboff, I. (2021) · IEEE/ACM Conference on Connected Health: Applications, Systems and Engineering Technologies · doi:10.1109/chase52844.2021.00009 · Cited by 18
“analysis [36], [42] and tremor severity assessment [19], [24].”
BackgroundSpECTRUM: Smart ECosystem for sTRoke patient׳s Upper limbs Monitoring
Bobin, M., Bimbard, F., Boukallel, M., Anastassova, M., & Ammi, M. (2019) · Smart Health · doi:10.1016/j.smhl.2019.01.001 · Cited by 18
Berbakov, L., Jovanović, Č., Svetel, M. V., Vasiljević, J., Dimić, G., & Radulović, N. (2019) · Sensors · doi:10.3390/s19194246 · Cited by 17
“A similar study was presented in the work [14], where the authors employed hidden Markov models to estimate the tremor type (resting, action and postural) and its severity.”
MethodMa, C., Zhang, P., Wang, J., Zhang, J., Pan, L., Li, X., Yin, C., Li, A., Zong, R., & Zhang, Z. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.106741 · Cited by 17
Intraoperative Quantification of MDS-UPDRS Tremor Measurements Using 3D Accelerometry: A Pilot Study
Smid, A., Elting, J. W. J., van Dijk, J. M. C., Otten, B., Oterdoom, D. L. M., Tamási, K., Heida, T., van Laar, T., & Drost, G. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11092275 · Cited by 17
“As tremor is generally a distinct sinusoidal movement, its dominant frequency can be approximated using the fast Fourier transform [33].”
BackgroundMethodWearable Electronics Sensors: Current Status and Future Opportunities
Nag, A., & Mukhopadhyay, S. C. (2015) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-18191-2_1 · Cited by 17
Akıllı ve Geleneksel Giyilebilir Sağlık Cihazlarında Nesnelerin İnterneti
Öcal, H., Doğru, İ. A., & Barışçı, N. (2018) · Journal of Polytechnic · doi:10.2339/politeknik.450290 · Cited by 17
“Rigas ve arkadaşları[60] Parkinson hastalarında titreme aktivitelerinin değerlendirilmesi HAYIR Hidden Markov Model 23 denek (18 parkinson hastası, 5 sağlıklı denek) % 87”
BackgroundTremor assessment using smartphone sensor data and fuzzy reasoning
Fuchs, C., Nobile, M. S., Zamora, G., Degeneffe, A., Kubben, P., & Kaymak, U. (2021) · BMC Bioinformatics · doi:10.1186/s12859-021-03961-8 · Cited by 17
“In another study [12] on the usefulness of accelerometer data, data of 18 Parkinson’s Disease patients and 5 control patients were gathered.”
BackgroundBuongiorno, D., Trotta, G. F., Bortone, I., Gioia, N. D., Avitto, F., Losavio, G., & Bevilacqua, V. (2018) · Lecture notes in computer science · doi:10.1007/978-3-319-95957-3_82 · Cited by 16
Development and Assessment of a Movement Disorder Simulator Based on Inertial Data
Carissimo, C., Cerro, G., Ferrigno, L., Golluccio, G., & Marino, A. (2022) · Sensors · doi:10.3390/s22176341 · Cited by 16
“Tremor is defined as a rhythmic involuntary and oscillatory movement that occurs in body parts such as hands, legs, vocal folds, the trunk, or head, and it is a clearly visible motor phenomenon in most cases [24].”
BackgroundPerera, T., Yohanandan, S. A. C., Thevathasan, W., Jones, M. B., Peppard, R. F., Evans, A. H., Tan, J. L., McKay, C. M., & McDermott, H. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/9/1516 · Cited by 16
Tremor analysis with wearable sensors correlates with outcome after thalamic deep brain stimulation
Rüegge, D., Mahendran, S., Stieglitz, L. H., Oertel, M. F., Gassert, R., Lambercy, O., Baumann, C. R., & Imbach, L. (2020) · Clinical Parkinsonism & Related Disorders · doi:10.1016/j.prdoa.2020.100066 · Cited by 16
“Using inertial measurement units (IMU), the long term fluctuation of tremor was analysed [19,20], showing for example, a decrease in tremor frequency over time for ET patients [21].”
Fitts’ Law Based Performance Metrics to Quantify Tremor in Individuals With Essential Tremor
Kim, J., Wichmann, T., Inan, O. T., & DeWeerth, S. P. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3129989 · Cited by 16
WristPrint: Characterizing User Re-identification Risks from Wrist-worn Accelerometry Data
Saleheen, N., Ullah, M. A., Chakraborty, S., Öneş, D. S., Srivastava, M. B., & Kumar, S. (2021) · ACM SIGSAC Conference on Computer and Communications Security (CCS) · doi:10.1145/3460120.3484799 · Cited by 15
“These novel inferences include routine behaviors such as eating [68], drinking [6], brushing and flossing [3, 4], and potentially sensitive ones such as smoking [5, 51, 58], tremors [57], and pain [48].”
BackgroundLin, F., Wang, Z., Zhao, H., Qiu, S., Liu, R., Shi, X., Wang, C., & Yin, W. (2023) · IEEE Transactions on Cognitive and Developmental Systems · doi:10.1109/tcds.2023.3266812 · Cited by 15
“The collected inertial data is being used in more studies for tremor detection and recognition, as well as tremor degree quantification [7], [9], [25], [26], [27], [28].”
MethodWearable Sensors for Prodromal Motor Assessment of Parkinson’s Disease using Supervised Learning
Rovini, E., Moschetti, A., Fiorini, L., Esposito, D., Maremmani, C., & Cavallo, F. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856804 · Cited by 14
“Nevertheless, interest towards upper limbs motion is growing, but related studies generally focused on a few tasks [10], [13] or a single symptom [14], [15].”
BackgroundChanna, A., Ruggeri, G., Ifrim, R., Mammone, N., Iera, A., & Popescu, N. (2024) · Electronics · doi:10.3390/electronics13061002 · Cited by 14
Remote Monitoring of Children With Chronic Illness Using Wearable Vest
Jansi, R., Amutha, R., & Radha, S. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816948-3.00008-8 · Cited by 14
Detection and analysis of Tremor using a system based on smart device and NoSQL database
Zheng, X., & Ordieres-Meré, J. B. (2015) · International Conference on Industrial Engineering and Systems Management · doi:10.1109/iesm.2015.7380165 · Cited by 14
“While these rating scales have clinical utility, they require the presence of a clinician for scoring, are subject to clinical judgment and bias, and cannot be used for continuous monitoring of tremor fluctuation patterns throughout the day or in home environments [7], [9].”
BackgroundTsipouras, M. G., Tzallas, A. T., Karvounis, E. C., Tsalikakis, D. G., Cancela, J., Pastorino, M., Waldmeyer, M. T. A., Konitsiotis, S., & Fotiadis, D. I. (2014) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI) · doi:10.1109/bhi.2014.6864332 · Cited by 13
“The main objective of PERFORM integrated project was to design, develop, and validate and exploit a multiparametric system for the continuous and effective assessment and monitoring of motor status in PD [2,3].”
BackgroundSelf-citationA system for finger tremor quantification in patients with Parkinson's disease
Bravo, M., Bermeo, A., Huerta, M., Llumiguano, C., Bermeo, J. P., Clotet, R., & Soto, A. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037623 · Cited by 13
Goubault, É., Nguyen, H., Bogard, S., Blanchet, P. J., Bézard, E., Vincent, C., Sarna, J. R., Monchi, O., & Duval, C. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00256 · Cited by 13
Data analytics for wearable IoT-based telemedicine
Constant, N. P., Cay, G., Ravichandran, V., Diouf, R., Akbar, U., & Mankodiya, K. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819246-7.00013-9 · Cited by 12
Sadhu, S., Solanki, D., Constant, N. P., Ravichandran, V., Cay, G., Saikia, M. J., Akbar, U., & Mankodiya, K. (2022) · Smart Health · doi:10.1016/j.smhl.2022.100351 · Cited by 12
Liu, S., Yuan, H., Liu, J., Lin, H., Yang, C., & Cai, X. (2021) · Technology and Health Care · doi:10.3233/thc-213205 · Cited by 12
“It has also been reported that the amplitude and peak power were closely related to the tremor severity [31–34].”
Kinetic tremor analysis using wearable sensors and fuzzy inference systems in Parkinson's disease
Fernández, L. P. S., Sánchez-Pérez, L. A., Concha-Gómez, P. D., & Shaout, A. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.104748 · Cited by 12
Clinicians’ Tendencies to Under-Rate Parkinsonian Tremors in the Less Affected Hand
Lee, H. J., Kim, S. K., Park, H.-Y., Kim, H. B., Jeon, H. S., Jung, Y. J., Oh, E., Kim, H. J., Yun, J. Y., Jeon, B. S., et al. (2015) · PLoS ONE · doi:10.1371/journal.pone.0131703 · Cited by 12
“These results are quite similar to performances reported by other studies [4, 8, 9, 12].”
BackgroundResultSáez, Y., Ureña, C., Valenzuela, J., García, A., & Collado, E. (2025) · Sensors · doi:10.3390/s25092763 · Cited by 11
“These technologies could transform PD treatment by enabling remote monitoring, reducing the need for frequent clinic visits, and allowing timely therapeutic adjustments based on continuous data [19,21,22].”
Design of a Multi-Sensors Wearable System for Continuous Home Monitoring of People With Parkinson’s
Sica, M., Varnosfaderani, O. T., Crowe, C., Kenny, L., Bocchino, A., O’Flynn, B., Mueller, D. S., Tedesco, S. A., Timmons, S., & Barton, J. J. (2024) · IEEE Access · doi:10.1109/access.2024.3375871 · Cited by 11
Assessment of a hand tremor based on analysis of the accelerometer signal
Wilk, B. (2016) · PRZEGLĄD ELEKTROTECHNICZNY · doi:10.15199/48.2016.11.36 · Cited by 11
“However, accelerometry provides objective measure of tremor frequency and amplitude so it is generally accepted as a gold standard [2, 7, 8].”
BackgroundRovini, E., Fiorini, L., Esposito, D., Maremmani, C., & Cavallo, F. (2019) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2019.8779543 · Cited by 11
An Intelligent Computing Based Approach for Parkinson Disease Detection
Ashis, R., & Swetapadma, A. (2018) · International Conference on Advances in Electronics Computers and Communications · doi:10.1109/icaecc.2018.8479490 · Cited by 11
Yang, T., Kan, P.-J., Lin, C., Lin, H., Chen, W., & Yau, H. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2940694 · Cited by 11
Is action tremor in Parkinson’s disease related to resting tremor?
Rana, A. Q., Siddiqui, I., Mosabbir, A., Qureshi, A.-R. M., Fattah, A., & Awan, N. (2013) · Neurological Research · doi:10.1179/1743132813y.0000000274 · Cited by 11
Yuan, H., Liu, S., Liu, J., Lin, H., Yang, C., Cai, X., Zeng, L., & Li, S. (2021) · Mathematical Problems in Engineering · doi:10.1155/2021/5669932 · Cited by 10
Learning Motion Primitives for the Quantification and Diagnosis of Mobility Deficits
Yan, F., Gong, J., Zhang, Q., & He, H. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3404357 · Cited by 10
Parkinson’s Disease Detection by Using Feature Selection and Sparse Representation
Mohamadzadeh, S., Pasban, S., Moghaddam, J. Z., & Shafiei, A. K. (2021) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-021-00626-y · Cited by 10
Hierarchical learning using deep optimum-path forest
Afonso, L. C. S., Pereira, C. R., Weber, S. A. T., Hook, C., Falcão, A. X., & Papa, J. P. (2020) · Journal of Visual Communication and Image Representation · doi:10.1016/j.jvcir.2020.102823 · Cited by 10
“[13] investigated an automated method that estimates the type and severity of tremors based on data acquired from accelerometers attached to specific positions at a patient’s body.”
MethodSchifino, G. P., da Cunha, M. J., Marchese, R. R., Mabília, V., Vian, L. H. A., Pereira, F. D. S., Cimolin, V., & Pagnussat, A. S. (2025) · Sensors · doi:10.3390/s25144313 · Cited by 9
“The innovation of assessment on symptoms through wearable devices offers a technique that is both easily applicable and widely accessible, significantly improving care for individuals with Parkinson’s disease [12–19, 44 , 56– 58 However, it is important to acknowledge the limitations of this study.”
Energy-efficient recognition of human activity in body sensor networks via compressed classification
Xiao, L., Li, R., Luo, J., & Xiao, Z. Q. (2016) · International Journal of Distributed Sensor Networks · doi:10.1177/1550147716679668 · Cited by 9
“Our energy-efficient CC approach is novel in the following two aspects: (1) data compression by RP on resource-constrained WBSN platforms and (2) activity classification by sparse representation and CS operating directly on the compressed samples.”
BackgroundMethodInfluentialA novel analytical approach to assess dyskinesia in patients with Parkinson disease
Ricci, M., Giannini, F., Saggio, G., Cenci, C., Lazzaro, G. D., & Pisani, A. (2018) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2018.8438666 · Cited by 9
Passive Monitoring of Parkinson Tremor in Daily Life: A Prototypical Network Approach
Evers, L. J. W., Raykov, Y. P., Heskes, T., Krijthe, J. H., Bloem, B. R., & Little, M. A. (2025) · Sensors · doi:10.3390/s25020366 · Cited by 8
Better Understanding Rehabilitation of Motor Symptoms: Insights from the Use of Wearables
Çelik, Y., Wall, C., Moore, J., & Godfrey, A. (2025) · Pragmatic and Observational Research · doi:10.2147/por.s396198 · Cited by 8
Task-Oriented Intelligent Solution to Measure Parkinson’s Disease Tremor Severity
AlMahadin, G., Lotfi, A., Carthy, M. M., & Breedon, P. (2021) · Journal of Healthcare Engineering · doi:10.1155/2021/9624386 · Cited by 8
“[12] conducted a study to estimate tremor severity using a set of wearable accelerometers, while subjects were performing ADL tasks.”
MethodRetractedKim, J., Parnell, C., Wichmann, T., & DeWeerth, S. P. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592136 · Cited by 8
“Although researchers have monitored the severity of tremor over extended periods of time using multiple motion sensor modules [8], [9], or electromyography (EMG) [7], [10], the long-term effects (and effectiveness) of the treatments have rarely been monitored because the available systems are bulky and may impede dail…”
BackgroundMethodProposal of a health care network based on big data analytics for PDs
Carnimeo, L., Trotta, G. F., Brunetti, A., Cascarano, G. D., Buongiorno, D., Loconsole, C., Sciascio, E. D., & Bevilacqua, V. (2019) · The Journal of Engineering · doi:10.1049/joe.2018.5142 · Cited by 8
Kan, P.-J., Lin, C., Su, C.-S., Lin, H., Chen, W., & Liang, C. (2019) · IEEE Access · doi:10.1109/access.2019.2916411 · Cited by 8
Casacanditella, L., Cosoli, G., Ceravolo, M., & Tomasini, E. P. (2017) · Journal of Physics Conference Series · doi:10.1088/1742-6596/882/1/012002 · Cited by 8
Design and analysis of proof mass based micro sensor for early detection of Parkinson’s disease
Prasad, G. R. K., Shameem, S., Srinivasulu, N., Renukavalli, C., Manasa, B., & Babu, P. S. S. (2017) · International Journal of Engineering & Technology · doi:10.14419/ijet.v7i1.5.9137 · Cited by 7
Escudeiro, G. P., Andrade, A. D. O., Cabral, A. M., Leite, M. A. A., Monteiro, L. V., da Silva, I. D. G., & Pessôa, B. L. (2021) · Research Society and Development · doi:10.33448/rsd-v10i15.22825 · Cited by 7
“(Esselink et al., 2006) The role of pallidotomy in the DBS era was explored by Spindola et al (2017), who found an average cost of U$99.5 for each 1% UPDRS reduction in the OFF phase of pallidotomy, versus U$873.00 for the same effect in DBS surgery.”
BackgroundInfluentialA System for Neuromotor Based Rehabilitation on a Passive Robotic Aid
Righi, M., Magrini, M., Dolciotti, C., & Moroni, D. (2021) · Sensors · doi:10.3390/s21093130 · Cited by 7
An inertial sensor-based algorithm for turning detection during gait
Meng, L., Huang, X., Yang, Y., Pang, J., Chen, L., & Ming, D. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630374 · Cited by 7
“Inertial measurement units (IMUs) have been widely accepted in gait assessment due to their portability, low cost and unconstrained environment requirement [3], [4].”
BackgroundPersonalised profiling to identify clinically relevant changes in tremor due to multiple sclerosis
Western, D., Neild, S. A., Jones, R., & Davies-Smith, A. (2019) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-019-0881-1 · Cited by 7
Bradley, L., Larsen, G. K., & Zhao, Y. (2016) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.6b04792 · Cited by 7
Rodríguez-Martín, D., & Pérez‐López, C. (2024) · Revista de Neurología · doi:10.33588/rn.7908.2024253 · Cited by 6
Triaxial Accelerometry Wireless System for Characterization of Parkinsonian Tremor
Carmona-Almazan, A., Dorantes-Méndez, G., Rodriguez-Arellano, J. F., & Mejia-Rodriguez, A. R. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630367 · Cited by 6
“Furthermore, these measures lack validation against real tremor amplitude, making it inadequate for measuring minimal changes in tremor intensity [2].”
BackgroundInfluentialA Ranking-based Weakly Supervised Learning model for telemonitoring of Parkinson’s disease
Alenezi, D. F., Shi, H., & Li, J. (2022) · IISE Transactions on Healthcare Systems Engineering · doi:10.1080/24725579.2022.2091065 · Cited by 6
“…area of research focuses on specific symptoms related to PD (Pastorino et al., 2011; Rigas et al., 2012; Yoneyama et al., 2014); for example, (Rigas et al., 2012) built a hidden Markov model for assessing tremor in PD. Lastly, one major area of research is related to the ability of using…”
BackgroundInfluentialA Multi-modal Tool Suite for Parkinson’s Disease Evaluation and Grading
Cascarano, G. D., Brunetti, A., Buongiorno, D., Trotta, G. F., Loconsole, C., Bortone, I., & Bevilacqua, V. (2019) · Smart innovation, systems and technologies · doi:10.1007/978-981-13-8950-4_24 · Cited by 6
Goubault, É., Bogard, S., Blanchet, P. J., Bézard, E., Vincent, C., Martino, D., Sarna, J. R., Monchi, O., & Duval, C. (2020) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.403 · Cited by 6
Activity Selection to Distinguish Healthy People from Parkinson’s Disease Patients Using I-DA
Tao, L., Wang, X., Peng, X., Yang, P., Qi, J., & Yang, Y. (2021) · International Conference on Mobility, Sensing and Networking (MSN) · doi:10.1109/msn53354.2021.00025 · Cited by 6
Ma, C., Zhang, P., Pan, L., Li, X., Yin, C., Li, A., Zong, R., & Zhang, Z. (2022) · Journal of King Saud University - Computer and Information Sciences · doi:10.1016/j.jksuci.2022.08.009 · Cited by 5
Wearing Sensors Inside and Outside of the Human Body for the Early Detection of Diseases
Poon, C. C. Y., Zheng, Y., Luo, N., Ding, X., & Zhang, Y. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-418662-0.00008-8 · Cited by 5
Guidelines for the economic analysis of a telematic platform for Parkinson's disease monitoring
Cancela, J., Arredondo, M. T., & Hurtado, O. (2013) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe.2013.6701606 · Cited by 5
Millimeter Wave Radar Calibration for Heart Rate Estimation using Bayesian Neural Networks
Parralejo, F., Paredes, J. A., Aranda, F. J., Álvarez, F. J., & Vicario, Á. (2023) · IEEE International Conference on Omni-layer Intelligent Systems (COINS) · doi:10.1109/coins57856.2023.10189316 · Cited by 5
“Additionally, the authors of [2] have explored a method to differentiate between patients with Parkinson’s Disease (PD) suffering from tremor and other symptoms and characterize the severity of the tremor.”
Analysis of Tremor During Grasp Using Ultrasound Imaging: Preliminary Study
Iyer, A., Sheng, Z., Zhang, Q., Kim, K., & Sharma, N. (2020) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob49111.2020.9224446 · Cited by 5
Bobin, M. (2018) · theses.fr (ABES) · doi:10.70675/0a4bfee8z1cdez4586zab5czcf332ea9576c · Cited by 5
Escamilla-Luna, O., Wister, M. A., & Hernández-Torruco, J. (2023) · Journal of Communications Software and Systems · doi:10.24138/jcomss-2022-0157 · Cited by 4
“However, the majority of investigations [17] [18] focused on the lower limbs, identifying evidence of changes in gait patterns and comparing them to medical scales to predict the course of neurodegenerative illness.”
Objective assessment of tremor in Parkinson's disease using the RehaBEElitation serious game
Mendes, L. C., Cabral, A. M., Alves, C. M., Morère, Y., & Andrade, A. D. O. (2023) · IEEE International Conference on Metrology for eXtended Reality, Artificial Intelligence and Neural Engineering (MetroXRAINE) · doi:10.1109/metroxraine58569.2023.10405668 · Cited by 4
AI scheme for high-accuracy and contactless assessment of Parkinson’s disease grades
Li, J., Zhao, Y., Liu, Y., Shan, P., Lian, C., Wang, X., & Wang, Y. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.107025 · Cited by 4
Ultrasound Imaging Triggered Tremor Suppression With Personalized Afferent Stimulation Frequency
Iyer, A., Xue, X., Ganesh, V., Jiang, X., Gallippi, C. M., Roque, D., & Sharma, N. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3519628 · Cited by 4
“Current sensing mechanisms for modeling, characterization, and classification of tremor include inertial measurement units (IMU), motion capture systems, and electromyography (EMG) [23], [24], [25], [26].”
Sha, D. L., Xie, W. C., Fan, X. L., & Li, Y. (2015) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.713-715.491 · Cited by 4
“In the early diagnosis of Parkinson's patients, in order to make the measured data more accurate, people used a lot of methods, such as the use of accelerometer[1,2], gyroscope [2], Electromyographic(EMG) [3] and so on.”
MethodHierarchy Definition for the Evaluation of a Telehealth System for Parkinson’s Disease Management
Cancela, J., Fico, G., Pastorino, M., & Arredondo, M. T. (2014) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-11128-5_250 · Cited by 4
Relationship between resting and action tremors in Parkinson’s disease
Rana, A. Q., & Saleh, M. A. (2016) · Journal of Neurosciences in Rural Practice · doi:10.4103/0976-3147.176192 · Cited by 4
“Analysis of tremor location was limited to upper extremities for ease of observation, and because this is the most prevalent location in PD populations.[2] The primary focus of this manuscript was to identify and classify the relationship between action and RTs.”
BackgroundQuantitative assessment of arm tremor in people with neurological disorders
Kim, J., Parnell, C., Wichmann, T., & DeWeerth, S. P. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591189 · Cited by 4
“Motion sensor systems that include one or more accelerometer modules have been used to quantify the severity and the frequency and amplitude of the tremor in laboratory settings [7]-[9].”
MethodSmart and Pervasive Health Systems—Challenges, Trends, and Future Directions
Rajagopalan, R. (2019) · Lecture notes in networks and systems · doi:10.1007/978-3-030-12388-8_29 · Cited by 4
Ranjan, R., Bhushan, B., Palaniswami, M. S., & Verma, A. (2020) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-55190-2_31 · Cited by 4
Towards a Visualizable, De-identified Synthetic Biomarker of Human Movement Disorders
Hu, H., Xiao, D., Rhodin, H., & Murphy, T. H. (2022) · Journal of Parkinson s Disease · doi:10.3233/jpd-223351 · Cited by 4
“While there are methods to directly measure parkinsonian movements using accelerometers and other sensors that hold considerable promise [12, 13], the procedure of data capture is complex and requires specific devices with often limited bandwidth.”
MethodSigcha, L. (2021) · UPM Digital Archive (Technical University of Madrid) · doi:10.20868/upm.thesis.68904 · Cited by 4
Assessment of Tremor Severity in Patients with Essential Tremor Using Smartwatches
Velasco, M. A., Blanco, R. L., Muñoz, J. P. R., Sobrino, M. D. D. C., Serrano, J. I., León, J. B., & Rocón, E. (2020) · Jornadas de Automática · doi:10.17979/spudc.9788497497749.0347 · Cited by 3
Subramanian, V., Dahiya, S., Thiruppathiraju, G., & Balusamy, B. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-89872-0.00005-8 · Cited by 3
Use of image processing for the detection of Parkinson's disease
Castro, J. C. M., Ruiz-Pinales, J., Lozano, J. M., & Guzmán-Cabrera, R. (2022) · doi:10.35429/jp.2022.16.6.27.32 · Cited by 3
Kumar, K., & Babu, T. R. G. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108057 · Cited by 3
Smid, A., Dominguez‐Vega, Z. T., van Laar, T., Oterdoom, D. L. M., Absalom, A. R., van Egmond, M. E., Drost, G., & van Dijk, J. M. C. (2024) · Neurosurgical Review · doi:10.1007/s10143-024-02312-4 · Cited by 3
A Comprehensive Analysis of Parkinson’s Disease Detection Through Inertial Signal Processing
Gil-Martín, M., Esteban-Romero, S., Fernández-Martínez, F., & San-Segundo, R. (2024) · International Conference on Agents and Artificial Intelligence (ICAART) · doi:10.5220/0012360100003636 · Cited by 3
“…researchers have experimented with a wide variety of machine learning algorithms, such as decision trees (Garcia-Magarino, Medrano, Plaza, & Olivan, 2016), random forests (Arora et al., 2015), hidden Markov models (Rigas et al., 2012), and neural networks (Cole, Roy, De Luca, Nawab, & Ieee, 2010).”
BackgroundXu, Z., Nan, F., Qi, J., Yang, Y., Wang, X., & Yang, P. (2023) · IEEE International Conference on Parallel and Distributed Systems (ICPADS) · doi:10.1109/icpads60453.2023.00139 · Cited by 3
A Mobile-based Tremor Detector Application for Patients with Parkinson’s Disease
Yi, P. X., Mohd., M., & Chelappan, K. (2019) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2019.0100719 · Cited by 3
Shen, T., Wang, J., Guo, L., Bai, Q., Zhang, H., Wang, S., & Xiong, D. (2018) · PubMed · doi:10.7507/1001-5515.201704037 · Cited by 3
DATA ANALYTICS FOR WEARABLE IOT-BASED TELEMEDICINE
Diouf, R. (2019) · Digital Commons - URI (University of Rhode Island) · doi:10.23860/thesis-diouf-rassoul-2019 · Cited by 3
INAMUL‐HAQ, I., & Jalil, A. (2012) · DiVA (Digitala Vetenskapliga Arkivet) · Cited by 3
Li, Z., Zhao, Y., Qi, J., Wang, X., Yang, Y., & Yang, P. (2023) · IEEE International Conference on Parallel and Distributed Systems (ICPADS) · doi:10.1109/icpads60453.2023.00134 · Cited by 2
“Such as: 1)Bradykinesi [13], 2)Tremor [14], 3)Gait freezing [15], 4)Muscle rigidity [16].”
Excessive daytime sleepiness and gait disturbances in patients with Parkinson’s disease
Xie, Y., Zhao, M., Guo, Y., Tian, P., Liu, S., & Xing, H. (2025) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2025.1626247 · Cited by 2
Compressed and Lightweight CNN for Real-Time Parkinson's Tremor Detection from Wearable IMU Data
Ozkoc, E., Zech, T. S., Pfeiffer, N., Göb, S., & Frickel, J. (2025) · Machine learning for signal processing ... · doi:10.1109/mlsp62443.2025.11204316 · Cited by 2
WaveTremor: Tremor Detection for Parkinson's Disease via Spatial-Temporal Learning
Chen, X., Koltermann, K., Clapham, J., Blackwell, G. G., Cloud, L. J., Pretzer‐Aboff, I., Shao, H., & Zhou, G. (2025) · IEEE/ACM Conference on Connected Health: Applications, Systems and Engineering Technologies · doi:10.1145/3721201.3721420 · Cited by 2
“Many studies [3, 7, 12, 14, 15, 17, 18] have used wearable sensors to detect Parkinson’s tremors.”
Influential
Metadata
- Authors
- Rigas, G., Tzallas, A. T., Tsipouras, M. G., Bougia, P., Tripoliti, E. E., Baga, D., Fotiadis, D. I., Tsouli, S. G., & Konitsiotis, S.
- Affiliations
- University of Ioannina (GR)
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2012-05
- Volume
- 16
- Issue
- 3
- Pages
- 478-487
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W2159209410
- Cited by
- 241
- References
- 34
- Citations by year
- 2026: 5 · 2025: 13 · 2024: 17 · 2023: 19 · 2022: 22 · 2021: 27 · 2020: 18 · 2019: 35 · 2018: 17 · 2017: 12 · 2016: 19 · 2015: 9 · 2014: 15 · 2013: 11 · 2012: 2
- FWCI
- 12.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Information Technology in Biomedicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Health Sciences › Medicine › Clinical Neurology › Parkinson's Disease Mechanisms and Treatments
- Keywords
- Parkinson's disease, tremor assessment, wearable sensors, accelerometer, resting tremor, postural tremor, hidden Markov models, parkinsonian motor symptoms
- MeSH terms
- Aged, Algorithms, Clothing, Humans, Markov Chains, Middle Aged, Movement, Parkinson Disease, Posture, Tremor, Case-Control Studies, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.