The DOI matches its Crossref record.
The Shape Design of Permanent Magnet for Permanent Magnet Synchronous Motor Considering Partial Demagnetization
Abstract
This paper presents a study on shape design of permanent magnets that is focused on robustness for cogging torque, sinusoidal back emf, and partial demagnetization of the permanent magnet of the outer rotor permanent magnet synchronous motor (PMSM). The simulation method for partial demagnetization is proposed and performed with four kinds of permanent magnet shape models at the fault current and two kinds of load angles corresponding to maximum torque operation and short circuit operation by finite-element method (FEM). The robust shape model of permanent magnets for large-sized hybrid electric vehicles is presented. The characteristics after partial demagnetization are analyzed and compared with experimental results for verification of the partial demagnetization effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A comprehensive review on hybrid electric vehicles: architectures and components
Singh, K. V., Bansal, H. O., & Singh, D. (2019) · Journal of Modern Transportation · doi:10.1007/s40534-019-0184-3 · Cited by 357
Modeling of Surface-Mounted Permanent Magnet Synchronous Motors With Stator Winding Interturn Faults
Romeral, L., Urresty, J. C., Riba Ruiz, J.-R., & Garcia Espinosa, A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2062480 · Cited by 282
Ruoho, S., Kolehmainen, J., Ikaheimo, J., & Arkkio, A. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2033592 · Cited by 264
Faiz, J., & Mazaheri-Tehrani, E. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2608950 · Cited by 207
Faults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review
Chen, Y., Liang, S., Li, W., Liang, H., & Wang, C. (2019) · Applied Sciences · doi:10.3390/app9102116 · Cited by 194
Urresty, J.-C., Riba, J.-R., Delgado, M., & Romeral, L. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2176127 · Cited by 181
A Back-emf Based Method to Detect Magnet Failures in PMSMs
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2207731 · Cited by 151
Moosavi, S. S., Djerdir, A., Amirat, Y. A., & Khaburi, D. A. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2015.04.062 · Cited by 96
Demagnetization Fault Diagnosis in Surface Mounted Permanent Magnet Synchronous Motors
Ebrahimi, B. M., & Faiz, J. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2217978 · Cited by 95
Comprehensive review on inter‐turn fault indexes in permanent magnet motors
Faiz, J., Nejadi‐Koti, H., & Valipour, Z. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0196 · Cited by 86
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2247046 · Cited by 73
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2012) · Electric Power Systems Research · doi:10.1016/j.epsr.2012.02.012 · Cited by 73
Stator short circuits detection in PMSM by means of Hilbert-Huang transform and energy calculation
Urresty, J., Riba, J., Romeral, L., Rosero, J., & Serna, J. (2009) · 2009 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives · doi:10.1109/demped.2009.5292789 · Cited by 29
Metadata
- Authors
- Kim, K.-C., Lim, S.-B., Koo, D.-H., & Lee, J.
- Venue
- IEEE Transactions on Magnetics
- Published
- 2006-10
- Volume
- 42
- Issue
- 10
- Pages
- 3485-3487
- ISSN
- 0018-9464 (ISSN-L)
- OpenAlex
- W2168890190
- Cited by
- 191
- References
- 0
- FWCI
- 6.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.