Analysis for Fault Detection of Vector-Controlled Permanent Magnet Synchronous Motor With Permanent Magnet Defect
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper analyzes the characteristics of a vector-controlled permanent-magnet synchronous motor (PMSM) with a permanent-magnet defect. A method for the diagnosis of the demagnetization of the permanent magnet in PMSM is proposed. In the proposed method, the magnetic field is calculated by the finite-element method, and then the flux linkage anddandqaxis inductances are calculated. They are introduced into the block diagram of the drive and control system. We have manufactured interior permanent-magnet motors, where one of four magnets is reduced by 10% and 20% in order to imitate the demagnetization. It is shown that the Fourier and wavelet results are in good agreement with the measured ones. This paper shows that the stator current and stator voltage using the proposed method are useful for the fault detection of demagnetized permanent magnet.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Urresty, J.-C., Riba, J.-R., Delgado, M., & Romeral, L. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2176127 · Cited by 181 · cited 1×
“Moreover, they analyzed a surface-mounted magnet synchronous motor with uniform and local demagnetization by 2-D FEM [8], and proposed an online methodology to detect the demagnetization based on the zero-sequence voltage [9], [10].”
MethodA Back-emf Based Method to Detect Magnet Failures in PMSMs
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2207731 · Cited by 151 · cited 2×
“have made a lot of contributions [4]–[10].”
Method
Research works printed but not linked: 10
- rosero, 2007, Fault detection by means of wavelet transform in a PMSM under demagnetization, Proc IEEE 33rd Annu Conf Ind Electron Soc, 1149
- 10.1109/TMAG.2006.870936 · DOI · Paper page
- 10.1109/TMAG.2009.2015942 · DOI · Paper page
- 10.1109/IEMDC.2011.5994841 · DOI
- 10.1109/TEC.2009.2037922 · DOI · Paper page
- ishikawa, 2009, Analysis of brushless DC motor by Simulink and FEM considering DC voltage drop and inverter properties, J Japan Soc Appl Electromagn Mech, 17, 77
- 10.1109/DEMPED.2011.6063630 · DOI
- 10.1109/TIE.2010.2066538 · DOI · Paper page
- 10.1109/ICEMS.2011.6073632 · DOI
- rajagopalan, 2004, diagnosis of potential rotor faults in brushless dc machines, Second International Conference on Power Electronics Machines and Drives (PEMD 2004), 2, 668
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“[102]-[104] CWT/DWT UDF, RS, RL, NINV, EV MS”
BackgroundFaiz, J., & Mazaheri-Tehrani, E. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2608950 · Cited by 207
Faults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review
Chen, Y., Liang, S., Li, W., Liang, H., & Wang, C. (2019) · Applied Sciences · doi:10.3390/app9102116 · Cited by 194
Choi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
Demagnetization Fault Indexes in Permanent Magnet Synchronous Motors—An Overview
Faiz, J., & Nejadi-Koti, H. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2015.2480379 · Cited by 119
“[16], [17], Hilbert-Huang transform [18], [19], and Cohen’s class distribution [20] are the transformations used for extract-”
Method
Metadata
- Authors
- Ishikawa, T., Seki, Y., & Kurita, N.
- Venue
- IEEE Transactions on Magnetics
- Published
- 2013-05
- Volume
- 49
- Issue
- 5
- Pages
- 2331-2334
- ISSN
- 0018-9464 (ISSN-L)
- 1941-0069
- OpenAlex
- W2073807880
- Cited by
- 73
- References
- 2
- FWCI
- 2.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis for Fault Detection of Vector-Controlled Permanent Magnet Synchronous Motor With Permanent Magnet Defect. https://app.cochat.ai/papers/10.1109/tmag.2013.2243135
- The paper
- Ishikawa, T., Seki, Y., & Kurita, N. (2013). Analysis for Fault Detection of Vector-Controlled Permanent Magnet Synchronous Motor With Permanent Magnet Defect. IEEE Transactions on Magnetics. https://doi.org/10.1109/tmag.2013.2243135
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.