Influence of the Stator Windings Configuration in the Currents and Zero-Sequence Voltage Harmonics in Permanent Magnet Synchronous Motors With Demagnetization Faults
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Demagnetization faults in permanent magnet synchronous motors may generate specific fault harmonic frequencies in the stator currents and the zero-sequence voltage component (ZSVC) spectra. Hence, by analyzing the stator currents or/and the ZSVC spectra it is possible to develop fault diagnosis schemes to detect such faults. In order to have a broad view of such effects, a representative set of stator windings configurations must be considered. By analyzing different stator windings configurations this paper shows that the amplitude of the harmonic frequencies of both the stator currents and the ZSVC spectrato be analyzed are significantly influenced by the stator windings configuration. It is also proved that depending on the winding configuration, new harmonic components may emerge in both spectra. The results presented in this paper may help to develop fault diagnosis schemes based on the acquisition and further analysis of the stator currents and the ZSVC harmonic components.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“On contrary, the ZSCC makes it possible to determine the PM demagnetization failure in high and low speeds with a correct accuracy.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [87]
In the citing paper
“The proper combination of the analyses of stator current and zero sequence current, or zero sequence and q-axis current enables fault determination for any range of speeds [87], [89].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [87]
In the citing paper
“In addition, fault detection accuracy based on current signal analysis is significantly influenced by inverter output harmonics, load fluctuations and controller settings [87], [88].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [87]
In the citing paper
“The studies [87] and [89] proved that the stator current harmonics show the DF condition for medium and high speeds.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [87]
Citations
Cites
Design of Rotating Electrical Machines
Pyrhönen, J., Jokinen, T., & Hrabovcová, V. (2008) · Wiley eBooks · doi:10.1002/9780470740095 · Cited by 1,431
EL-Refaie, A. M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030211 · Cited by 1,373 · cited 1×
“In practice, machines with high number of poles as applied in low-speed drives often have a number of slots per pole per phase, , less than 1 [23].”
BackgroundBrushless permanent-magnet motor design
Hanselman, D. C. (1994) · DigitalCommons (California Polytechnic State University) · Cited by 1,155
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724 · cited 1×
“Under a fault condition this extra leg is connected to the neutral point of the PMSM, thus replacing the faulty phase [18], [19].”
BackgroundDesign considerations for fractional-slot winding configurations of synchronous machines
Bianchi, N., Bolognani, S., Pre, M. D., & Grezzani, G. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.876070 · Cited by 447 · cited 1×
“However, PMSMs with higher usually generate a more sinusoidal back electromotive force(EMF) waveform and magnetomotive force distribution [24] as well as lower torque ripple and power loss [25].”
BackgroundDetecting Rotor Faults in Low Power Permanent Magnet Synchronous Machines
le Roux, W., Harley, R. G., & Habetler, T. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886620 · Cited by 274 · cited 3×
“It has been proved that depending on the stator windings configuration, some of the harmonic frequencies predicted by (2) may not appear in the stator currents spectra [2], [32].”
BackgroundRuoho, S., Kolehmainen, J., Ikaheimo, J., & Arkkio, A. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2033592 · Cited by 264 · cited 1×
“This effect increases the copper losses and the permanent magnets temperature, which in turn increases the stator currents [10].”
BackgroundRuiz, J.-R. R., Rosero, J. A., Espinosa, A. G., & Romeral, L. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2015942 · Cited by 231 · cited 2×
“According to (2), demagnetization faults generate characteristic fractional harmonics in the current spectrum that may be used to detect this type of faults [16], [32], [34].”
BackgroundSelf-citationHong, J., Park, S., Hyun, D., Kang, T.-J., Lee, S. B., Kral, C., & Haumer, A. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2191253 · Cited by 219 · cited 2×
“Motor current signature analysis (MCSA) is possibly the most popular fault detection method in PMSMs [15], which is based on the analysis of the stator currents harmonics.”
BackgroundMethodParasitic Effects in PM Machines With Concentrated Windings
Magnussen, F., & Lendenmann, H. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.904400 · Cited by 204 · cited 2×
“They also present reduced winding loss [29], an inherently higher leakage inductance that limits the short-circuit currents [26] and allows extending the flux weakening region [30].”
Background
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“The proper combination of the analyses of stator current and zero sequence current, or zero sequence and q-axis current enables fault determination for any range of speeds [87], [89].”
BackgroundInfluentialChoi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
“PM motors have also been discussed in [100] and [101].”
BackgroundDiscernment of Broken Magnet and Static Eccentricity Faults in Permanent Magnet Synchronous Motors
Goktas, T., Zafarani, M., & Akin, B. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2015.2512602 · Cited by 140
“In [14], it is shown that the stator winding configurations also affects the characteristic fault signatures under demagnetization faults in currents and zero-sequence voltage of PMSMs.”
BackgroundDemagnetization Fault Indexes in Permanent Magnet Synchronous Motors—An Overview
Faiz, J., & Nejadi-Koti, H. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2015.2480379 · Cited by 119
“K is the demagnetization degree [23], [27], [28] which is obtained from the”
BackgroundMethodSkowron, M., Orłowska-Kowalska, T., & Kowalski, C. T. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3146557 · Cited by 113
Han, Y., Chen, S., Gong, C., Zhao, X., Zhang, F., & Li, Y. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3245052 · Cited by 99
“Many up-to-date studies have developed demagnetization diagnosis techniques for the IPM motors, which can be categorized into offline strategies and online strategies [3], [4], [5], [6], [7], [8], [9], [10], [11], [12].”
BackgroundMethodMoosavi, S. S., Djerdir, A., Amirat, Y. A., & Khaburi, D. A. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2015.04.062 · Cited by 96
Pietrzak, P., & Wolkiewicz, M. (2023) · Sensors · doi:10.3390/s23041757 · Cited by 76
“It consists in the analysis of increases in the amplitudes of frequency components characteristic of PM damage [14,15].”
BackgroundAn Investigation of Motor Topology Impacts on Magnet Defect Fault Signatures
Zafarani, M., Göktaş, T., Akin, B., & Fedigan, S. E. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2609380 · Cited by 61
“In [17], the effect of winding configuration on the harmonic content of the stator current and zero-voltage sequence component due to demagnetization fault is discussed and simulated.”
BackgroundZhao, J., Wang, L., Xu, L. H., Dong, F., Song, J., & Yang, X. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3050360 · Cited by 59
“In [12], the variation of harmonic components in the spectrum of stator current and zero-sequence voltage signal is used to detect the demagnetization fault of PMSM.”
MethodHang, J., Wu, H., Ding, S., Hua, W., & Wang, Q. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2924929 · Cited by 57
“The previous literatures about the PMSM fault diagnosis mainly focus on interturn fault [7], [8], eccentricity fault [9]– [11], demagnetization fault [12], [13], and open-phase fault [14]–[16], while the study on the HRC fault detection of the PMSM drive system is relatively little.”
BackgroundGyftakis, K. N., Rasid, S. A., Skarmoutsos, G. A., & Mueller, M. A. (2021) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2021.3071598 · Cited by 52
“Nevertheless, frequency signature analysis is influenced severely by the winding configuration [20], and the slot number as these harmonics are influenced by the harmonics, which are generated by the slotting effect [18].”
BackgroundZhang, J., Hang, J., Ding, S., & Cheng, M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2587670 · Cited by 52
“However, the detections of eccentricity fault [13], [14], interturn fault [15], [16], and demagnetization fault [17], [18] rather than HRC are focused on for the PMSM.”
BackgroundHang, J., Zhang, J., Cheng, M., & Zhang, B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2479846 · Cited by 47
“However, to the best of the authors’ knowledge, the previous literatures mostly focus on detection of the interturn fault [11]–[13], eccentricity fault [14], [15], and demagnetization fault [16], [17] in the PMSM rather than the HRC, in addition to [18].”
BackgroundInduction Motors Condition Monitoring System with Fault Diagnosis Using a Hybrid Approach
Chang, H., Jheng, Y.-M., Kuo, C., & Hsueh, Y.-M. (2019) · Energies · doi:10.3390/en12081471 · Cited by 44
Post-demagnetization characteristics of permanent magnet synchronous machines
Choi, G., & Jahns, T. M. (2015) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7309911 · Cited by 41
“However, there are some conditions for which MCSA cannot be used such as uniform demagnetization [5], oscillating load torque that produces the same frequency components [7], and certain PM machines with series-connected integral-slot winding configurations that average out the detection signal [9].”
BackgroundDemagnetization characteristics of permanent magnet synchronous machines
Choi, G., & Jahns, T. M. (2014) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2014.7048542 · Cited by 39
Usman, A., & Rajpurohit, B. S. (2019) · IEEE Access · doi:10.1109/access.2019.2946694 · Cited by 35
“Urresty in [18] who has diagnosed the demagnetization effect with a zero-sequence voltage and current signatures.”
BackgroundSkarmoutsos, G. A., Gyftakis, K. N., & Mueller, M. A. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2021.3053993 · Cited by 33
Ko, Y., Lee, Y., Oh, J., Park, J., Chang, H., & Kim, N. (2024) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2024.111377 · Cited by 33
Zafarani, M., Göktaş, T., Akin, B., & Fedigan, S. E. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2561900 · Cited by 28
“The zero sequence voltage components (ZSVC) is an example which is introduced in [15] to detect the demagnetization fault.”
BackgroundUsman, A., Doiphode, N. T., & Rajpurohit, B. S. (2019) · International Conference on Electrical Drives and Power Electronics (EDPE) · doi:10.1109/edpe.2019.8883929 · Cited by 26
“Similarly, paper [17] discusses the influence of SITF on zero voltage harmonics and [18] describes on the fault tolerant mechanism.”
BackgroundHang, J., Zhang, J., Ding, S., Huang, Y., & Wang, Q. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2978139 · Cited by 25
“So far, many fault diagnosis methods are proposed for the PMSM, mainly focusing on short-circuit fault [7]–[10], static/dynamic eccentricity [13]–[15], partial/uniform demagnetization [16]–[19], and open-phase fault [20]–[22], while the research on the HRC is relatively few for the PMSM drive system.”
BackgroundSkarmoutsos, G. A., Gyftakis, K. N., & Mueller, M. A. (2021) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2021.3123662 · Cited by 25
Demagnetization faults analysis in a BLDC motor for diagnostic purposes
Athanasopoulos, D. K., Karagkounis, P. D., Kappatou, J. C., & Tsotoulidis, S. (2014) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2014.6960437 · Cited by 24
Study of the Total Demagnetization Fault of an AFPM Wind Generator
Barmpatza, A. C., & Kappatou, J. C. (2020) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2020.3021215 · Cited by 23
“In the international literature [8]–[9], [11], [31] is referred that both the demagnetization and the eccentricity fault create new harmonics in the stator current spectrum of a RFPM synchronous machine that are given by (11).”
BackgroundMethodMelecio, J. I., Djurović, S., & Schofield, N. (2019) · The Journal of Engineering · doi:10.1049/joe.2018.8048 · Cited by 22
Detection of Eccentricity Faults in Five-Phase Ferrite-PM Assisted Synchronous Reluctance Machines
López-Torres, C., Riba, J., García, A., & Romeral, L. (2017) · Applied Sciences · doi:10.3390/app7060565 · Cited by 21
“The results presented in [20,21] for PMSMs (permanent magnet synchronous machines) prove that the ZSVC approach has a better accuracy and sensitivity than the analysis of the stator currents spectra, particularly when the motor operates under low-speed conditions.”
BackgroundResultSelf-citationGritli, Y., Tani, A., Rossi, C., & Casadei, D. (2018) · Mathematics and Computers in Simulation · doi:10.1016/j.matcom.2018.06.002 · Cited by 20
On-Line Detection of Demagnetization for Permanent Magnet Synchronous Motor via Flux Observer
Cao, L., & Wu, Z. (2022) · Machines · doi:10.3390/machines10050354 · Cited by 20
Yu, Y., Gao, H., Chen, Q., Liu, P., & Niu, S. (2022) · Energies · doi:10.3390/en15082952 · Cited by 20
Quantitative Fault Severity Estimation for High-Resistance Connection in PMSM Drive System
Hang, J., Yan, D., Xia, M., Ding, S., & Wang, Q. (2019) · IEEE Access · doi:10.1109/access.2019.2901121 · Cited by 19
“In this paper, the artificial neutral point is created by using three-phase balanced resistor network [15], [32], [38], as presented in Fig.”
BackgroundMethodFault Diagnosis and Tolerance on Reliability of Automotive Motor Control System: A Review
Choi, C., & Lee, W. (2022) · International Journal of Automotive Technology · doi:10.1007/s12239-022-0102-2 · Cited by 18
Gyftakis, K. N., Garcia-Calva, T. A., Skarmoutsos, G. A., Moríñigo-Sotelo, D., Mueller, M. A., & Romero-Troncoso, R. D. J. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3221699 · Cited by 18
“monics are influenced by the harmonics, which are generated by the slotting effect [21].”
BackgroundNavarro-Navarro, Á., Ruiz-Sarrio, J. E., Biot-Monterde, V., Daviu, J. A. A., Becker, V., & Urschel, S. (2023) · Machines · doi:10.3390/machines11020288 · Cited by 17
Model-Based Luenberger State Observer for Detecting Interturn Short Circuits in PM Machines
Qin, Y., Li, G., Zhu, Z. Q., Foster, M. P., Stone, D. A., Jia, C. J., & Mckeever, P. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3478840 · Cited by 17
“Thesignal-based fault detection methods use spectral tools to detect changes in signals, such as stator phase current [3], zero sequence current component (ZSCC) [18], and ZSVC [19].”
Study of a Combined Demagnetization and Eccentricity Fault in an AFPM Synchronous Generator
Barmpatza, A. C., & Kappatou, J. C. (2020) · Energies · doi:10.3390/en13215609 · Cited by 17
Zhan, H., Wu, L., Lyu, Z., Du, Y., & Fang, Y. (2022) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2022.3217401 · Cited by 17
“This is an improvement and supplement for [17] and [18].”
BackgroundCurrent Signature Modeling of Surface-Mounted PMSM Drives With Current Sensors Faults
Attaianese, C., D’Arpino, M., Monaco, M. D., & Noia, L. P. D. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3282314 · Cited by 17
“Theyhaveapproachedmainlythe detectionofopenphasefault[6],[7],statorwindinginter-turn shortcircuit[8],[9],[10],[11],[12],rotordemagnetization[13], [14],[15],airgapeccentricity[16],[17],[18],[19].”
Li, J., Li, Z., Zhang, J., Zhao, S., Cheng, F., Qian, C., Hu, X., & Zhou, G. (2023) · Sustainability · doi:10.3390/su152316326 · Cited by 16
Gyftakis, K. N., Skarmoutsos, G. A., Barajas-Solano, I., Burchell, J., & Mueller, M. A. (2023) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2023.3299905 · Cited by 14
“Several methods [9], [10], [11], [12], [13], [14], [15], [16], [17] have been proposed in the literature, aiming to detect this fault while the machine is under operation.”
BackgroundOverview of IoT Security Challenges and Sensors Specifications in PMSM for Elevator Applications
Vlachou, E. I., Vlachou, V. I., Efstathiou, D. E., & Karakatsanis, T. S. (2024) · Machines · doi:10.3390/machines12120839 · Cited by 13
Candelo-Zuluaga, C., Riba, J., Thangamuthu, D. V., & García, A. (2020) · Energies · doi:10.3390/en13133496 · Cited by 13
“In addition, different demagnetization levels are studied by means of finite element analysis (FEA), since it is a widely recognized method to analyze in detail the behavior of electric machines [24].”
BackgroundMethodSelf-citationDemagnetization faults detection in an axial flux permanent magnet synchronous generator
Barmpatza, A. C., & Kappatou, J. C. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062349 · Cited by 12
“From the literature [3], [5], [9], [16], [8] it is known that the stator current waveform spectrum of a demagnetized permanent magnet machine, with no symmetrical stator windings, will contain extra harmonics which are expressed by the equation (1):”
BackgroundDetection of Inter-Turn Faults in Multi-Phase Ferrite-PM Assisted Synchronous Reluctance Machines
Candelo-Zuluaga, C., Riba, J., López-Torres, C., & García, A. (2019) · Energies · doi:10.3390/en12142733 · Cited by 12
Self-citationStudy of the Demagnetization Fault in an AFPM Machine in Relation with the Magnet Location
Barmpatza, A. C., & Kappatou, J. C. (2018) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2018.8506738 · Cited by 11
“In [5] a method that is based in zero sequence current component is presented, while in [6]-[7] both stator current and zero sequence current component are used for the fault investigation.”
MethodElectrical Signature Analysis for Condition Monitoring of Permanent Magnet Synchronous Machine
Salomon, C. P., FERREIRA, C., Lambert‐Torres, G., TEIXEIRA, C. E., SILVA, L. E. B. D., Sant’Ana, W. C., Bonaldi, E. L., & de Oliveira, L. E. L. (2018) · Advances in Electrical and Computer Engineering · doi:10.4316/aece.2018.04011 · Cited by 10
Investigation of the combined eccentricity and demagnetization fault in an AFPMSG
Barmpatza, A. C., & Kappatou, J. C. (2020) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icem49940.2020.9270725 · Cited by 10
“In the international literature [28]-[30], there are theoretical analyses which prove that the fault related harmonics in the stator current spectrum of a radial flux permanent magnet synchronous machine, when demagnetization or eccentricity fault exists, can be given by (7):”
BackgroundFinite Element Modeling of Stator Winding Faults in Permanent Magnet Synchronous Motor: Part II
Usman, A., Doiphode, N. T., & Rajpurohit, B. S. (2019) · International Conference on Electrical Drives and Power Electronics (EDPE) · doi:10.1109/edpe.2019.8883937 · Cited by 10
“The zero-sequence current analysis is done in paper [16] for the detection and diagnosis of stator faults in PMSM.”
MethodZarate, S., Almandoz, G., Ugalde, G., Poza, J., & Escalada, A. J. (2018) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2018.8506755 · Cited by 9
“As it has been seen in [6], [7], the demagnetization decreases the torque capacity.”
BackgroundInfluentialFault Diagnosis in Electric Generators: Methods, Trends and Challenges
Ptochos, K., Koutrakos, K., & Mitronikas, E. D. (2025) · Energies · doi:10.3390/en18236210 · Cited by 8
Hang, J., Li, Y., Ding, S., Tang, C., & Wang, Q. (2017) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2017.8056039 · Cited by 8
Chen, S., Han, Y., Liu, Y., Ma, Z., Gong, C., & Lin, G. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3454293 · Cited by 7
“The rationale behind it is that the demagnetization fault can generate more or less harmonic components in the faulty motors compared to the healthy ones [18], [19], [20].”
Rahman, A., Dutta, R., Chu, G., Xiao, D., Gao, M., & Rahman, M. F. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362902 · Cited by 7
“Moreover, partial demagnetization increases the vibration and acoustic In [12], the effect of different stator winding configurations on stator current and ZSV under demagnetization has been discussed.”
BackgroundHou, Z., Huang, J., Liu, H., Liu, Z., Ye, M., & Yang, J. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0625 · Cited by 8
Hang, J., Tang, C., Ding, S., Hu, C., Li, G., & Wang, Q. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8216867 · Cited by 4
Zarate, S., Egea, A., Almandoz, G., McCloskey, A., Galfarsoro, U., & Urdangarin, A. (2020) · International Electric Drives Production Conference · doi:10.1109/edpc51184.2020.9388212 · Cited by 4
“Several works have been done in order to detect demagnetization [6], [7].”
BackgroundUsman, A., Rajpurohit, B. S., Sharma, V. K., Divakar, B. P., & Agamloh, E. B. (2021) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/sdemped51010.2021.9605564 · Cited by 4
Ghods, M., Tabarniarami, Z., Faiz, J., & Abedini, M. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3536548 · Cited by 3
“The effects of the stator winding con fi gura-tion on the harmonics of the zero-sequence voltage component (ZSVC) have been addressed in [17], when the machine operates under demagnetization faults.”
Yang, L., Deng, C., & Wang, G. (2021) · Journal of Nanoelectronics and Optoelectronics · doi:10.1166/jno.2021.3039 · Cited by 3
MCSA versus Flux Monitoring for Demagnetization Diagnosis in Axial-Flux PM Generators
Skarmoutsos, G. A., Gyftakis, K. N., & Mueller, M. (2021) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/sdemped51010.2021.9605530 · Cited by 3
Antunes, H. R. P., Fonseca, D. S. B., & Cardoso, A. J. M. (2022) · International Electronic Conference on Machines and Applications (IECMA) · doi:10.3390/iecma2022-12891 · Cited by 3
“Discrimination between both ITSCF and demagnetizing faults is analyzed in [9].”
BackgroundModelling and analysis of PPF in PMSM
Hang, J., Zhang, J., Ding, S., & Cheng, M. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0624 · Cited by 3
Li, W., Zhang, M. W., Zhao, X. H., & Sheng, Y. (2019) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2019.8922155 · Cited by 2
Gyftakis, K. N., Skarmoutsos, G. A., Barajas-Solano, I., Burchell, J., & Mueller, M. A. (2022) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce50734.2022.9947661 · Cited by 2
A Review on Poles Demagnetization in Permanent Magnet Motors
Patel, M. G. (2024) · Journal of Electrical Systems · doi:10.52783/jes.2978 · Cited by 1
“The use of high-quality rare earth magnets in PM machines makes a cost-saving challenging task [1].”
BackgroundMethodInfluentialXiong, Y., Zhao, J., Yan, S., Wei, K., & Zhou, H. (2024) · Applied Sciences · doi:10.3390/app142411943 · Cited by 1
Rahman, A., Dutta, R., Chu, G., Xiao, D., Gao, M., & Rahman, M. F. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3619020 · Cited by 1
“Many of these methods work only under steady state conditions and also, the winding configuration can influence the fault signature [5].”
Gao, C., Song, Z., Dang, J., Xu, X., & Si, J. (2026) · Electronics · doi:10.3390/electronics15102094 · Cited by 1
2013 Index IEEE Transactions on Magnetics Vol. 49
(2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2296662 · Cited by 1
Fault diagnosis in a permanent magnet synchronous motor using deep learning
Quseiri Darbandeh, P. (2024) · doi:10.24405/15302 · Cited by 1
Analysis of fault characteristics of uniform demagnetization of permanent magnet synchronous motor
Li, T., & Yu, Y. (2021) · 4th International Symposium on Power Electronics and Control Engineering (ISPECE 2021) · doi:10.1117/12.2619442
“Literature [7] analyzes the harmonic components in the frequency spectrum of the stator current and zero sequence voltage signals, and uses the change in the amplitude of the harmonic components in the frequency to detect PMSM demagnetization faults; Literature [8] uses the zero sequence voltage component (ZSVC) As a…”
MethodSun, Y., Mo, Y., Tao, Y., & Zheng, Z. (2025) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2025.3631712
“…for detecting partial demagneti-zation in integral-slot PMSMs, where the fault-induced fractional harmonic magnetic field produces zero magnetic flux linkage across the entire phase winding, resulting in no fractional harmonics in the EMF or currents in the integral slot winding [12], [13].”
Chen, Z., Zhaoxu, S., Lei, W., Yifan, P., & Baiou, S. (2026) · International Journal of Applied Electromagnetics and Mechanics · doi:10.1177/13835416261417766
Chen, Z., Xu, H., Gao, C., Pu, Y., & Shen, J. (2026) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2026.3727053
“Existing studies have shown that the magnet arrangement, magnetization state, local temperature, reverse magnetic field, and fault distribution a ff ect both the severity of demagnetization and its external manifestations [9], [10], [11].”
Articles indexats publicats per investigadors del Campus de Terrassa: 2014
Biblioteca, U. P. D. C. C. D. T. (2015) · RECERCAT (Consorci de Serveis Universitaris de Catalunya)
Metadata
- Authors
- Urresty, J.-C., Riba, J.-R., & Romeral, L.
- Affiliations
- Universitat Politècnica de Catalunya (ES)
- ORCID
- Riba, Jordi-Roger
- Venue
- IEEE Transactions on Magnetics
- Published
- 2013-08
- Volume
- 49
- Issue
- 8
- Pages
- 4885-4893
- ISSN
- 0018-9464 (ISSN-L)
- 1941-0069
- OpenAlex
- W2002813721
- Cited by
- 73
- References
- 35
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 6 · 2023: 7 · 2022: 9 · 2021: 8 · 2020: 6 · 2019: 9 · 2018: 5 · 2017: 5 · 2016: 5 · 2015: 4 · 2014: 2
- FWCI
- 2.20
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Magnetics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet synchronous motor, demagnetization fault, stator winding configuration, zero-sequence voltage, stator current harmonics, fault diagnosis, harmonic spectrum analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.