Influence of the Stator Windings Configuration in the Currents and Zero-Sequence Voltage Harmonics in Permanent Magnet Synchronous Motors With Demagnetization Faults
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Demagnetization faults in permanent magnet synchronous motors may generate specific fault harmonic frequencies in the stator currents and the zero-sequence voltage component (ZSVC) spectra. Hence, by analyzing the stator currents or/and the ZSVC spectra it is possible to develop fault diagnosis schemes to detect such faults. In order to have a broad view of such effects, a representative set of stator windings configurations must be considered. By analyzing different stator windings configurations this paper shows that the amplitude of the harmonic frequencies of both the stator currents and the ZSVC spectrato be analyzed are significantly influenced by the stator windings configuration. It is also proved that depending on the winding configuration, new harmonic components may emerge in both spectra. The results presented in this paper may help to develop fault diagnosis schemes based on the acquisition and further analysis of the stator currents and the ZSVC harmonic components.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“On contrary, the ZSCC makes it possible to determine the PM demagnetization failure in high and low speeds with a correct accuracy.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [87]
In the citing paper
“The proper combination of the analyses of stator current and zero sequence current, or zero sequence and q-axis current enables fault determination for any range of speeds [87], [89].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [87]
In the citing paper
“In addition, fault detection accuracy based on current signal analysis is significantly influenced by inverter output harmonics, load fluctuations and controller settings [87], [88].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [87]
In the citing paper
“The studies [87] and [89] proved that the stator current harmonics show the DF condition for medium and high speeds.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [87]
Citations
Cites
Design of Rotating Electrical Machines
Pyrhönen, J., Jokinen, T., & Hrabovcová, V. (2008) · Wiley eBooks · doi:10.1002/9780470740095 · Cited by 1,431
EL-Refaie, A. M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030211 · Cited by 1,373 · cited 1×
“In practice, machines with high number of poles as applied in low-speed drives often have a number of slots per pole per phase, , less than 1 [23].”
BackgroundBrushless permanent-magnet motor design
Hanselman, D. C. (1994) · DigitalCommons (California Polytechnic State University) · Cited by 1,155
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724 · cited 1×
“Under a fault condition this extra leg is connected to the neutral point of the PMSM, thus replacing the faulty phase [18], [19].”
BackgroundDesign considerations for fractional-slot winding configurations of synchronous machines
Bianchi, N., Bolognani, S., Pre, M. D., & Grezzani, G. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.876070 · Cited by 447 · cited 1×
“However, PMSMs with higher usually generate a more sinusoidal back electromotive force(EMF) waveform and magnetomotive force distribution [24] as well as lower torque ripple and power loss [25].”
BackgroundDetecting Rotor Faults in Low Power Permanent Magnet Synchronous Machines
le Roux, W., Harley, R. G., & Habetler, T. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886620 · Cited by 274 · cited 3×
“It has been proved that depending on the stator windings configuration, some of the harmonic frequencies predicted by (2) may not appear in the stator currents spectra [2], [32].”
BackgroundRuoho, S., Kolehmainen, J., Ikaheimo, J., & Arkkio, A. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2033592 · Cited by 264 · cited 1×
“This effect increases the copper losses and the permanent magnets temperature, which in turn increases the stator currents [10].”
BackgroundRuiz, J.-R. R., Rosero, J. A., Espinosa, A. G., & Romeral, L. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2015942 · Cited by 231 · cited 2×
“According to (2), demagnetization faults generate characteristic fractional harmonics in the current spectrum that may be used to detect this type of faults [16], [32], [34].”
BackgroundSelf-citationHong, J., Park, S., Hyun, D., Kang, T.-J., Lee, S. B., Kral, C., & Haumer, A. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2191253 · Cited by 219 · cited 2×
“Motor current signature analysis (MCSA) is possibly the most popular fault detection method in PMSMs [15], which is based on the analysis of the stator currents harmonics.”
BackgroundMethodParasitic Effects in PM Machines With Concentrated Windings
Magnussen, F., & Lendenmann, H. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.904400 · Cited by 204 · cited 2×
“They also present reduced winding loss [29], an inherently higher leakage inductance that limits the short-circuit currents [26] and allows extending the flux weakening region [30].”
Background
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“The proper combination of the analyses of stator current and zero sequence current, or zero sequence and q-axis current enables fault determination for any range of speeds [87], [89].”
BackgroundInfluentialChoi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
“PM motors have also been discussed in [100] and [101].”
BackgroundDiscernment of Broken Magnet and Static Eccentricity Faults in Permanent Magnet Synchronous Motors
Goktas, T., Zafarani, M., & Akin, B. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2015.2512602 · Cited by 140
“In [14], it is shown that the stator winding configurations also affects the characteristic fault signatures under demagnetization faults in currents and zero-sequence voltage of PMSMs.”
BackgroundDemagnetization Fault Indexes in Permanent Magnet Synchronous Motors—An Overview
Faiz, J., & Nejadi-Koti, H. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2015.2480379 · Cited by 119
“K is the demagnetization degree [23], [27], [28] which is obtained from the”
BackgroundMethodSkowron, M., Orłowska-Kowalska, T., & Kowalski, C. T. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3146557 · Cited by 113
Metadata
- Authors
- Urresty, J.-C., Riba, J.-R., & Romeral, L.
- Affiliations
- Universitat Politècnica de Catalunya (ES)
- ORCID
- Riba, Jordi-Roger
- Venue
- IEEE Transactions on Magnetics
- Published
- 2013-08
- Volume
- 49
- Issue
- 8
- Pages
- 4885-4893
- ISSN
- 0018-9464 (ISSN-L)
- 1941-0069
- OpenAlex
- W2002813721
- Cited by
- 73
- References
- 35
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 6 · 2023: 7 · 2022: 9 · 2021: 8 · 2020: 6 · 2019: 9 · 2018: 5 · 2017: 5 · 2016: 5 · 2015: 4 · 2014: 2
- FWCI
- 2.20
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Magnetics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet synchronous motor, demagnetization fault, stator winding configuration, zero-sequence voltage, stator current harmonics, fault diagnosis, harmonic spectrum analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.