The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Bit-Patterned Magnetic Recording: Theory, Media Fabrication, and Recording Performance
Open accessAbstract
Bit-patterned media (BPM) for magnetic recording provides a route to thermally stable data recording at >1 Tb/in2and circumvents many of the challenges associated with extending conventional granular media technology. Instead of recording a bit on an ensemble of random grains, BPM comprises a well-ordered array of lithographically patterned isolated magnetic islands, each of which stores 1 bit. Fabrication of BPM is viewed as the greatest challenge for its commercialization. In this paper, we describe a BPM fabrication method that combines rotary-stage e-beam lithography, directed self-assembly of block copolymers, self-aligned double patterning, nanoimprint lithography, and ion milling to generate BPM based on CoCrPt alloy materials at densities up to 1.6 Td/in2. This combination of novel fabrication technologies achieves feature sizes of2(roughly equivalent to 1.3 Tb/in2) demonstrate a raw error rate-2, which is consistent with the recording system requirements of modern hard drives. Extendibility of BPM to higher densities and its eventual combination with energy-assisted recording are explored.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atomic Layer Deposition: An Overview
George, S. M. (2010) · Chemical Reviews · doi:10.1021/cr900056b · Cited by 5,814
A mechanism of magnetic hysteresis in heterogeneous alloys
Stoner, E. C., & Wohlfarth, E. P. (1948) · Philosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences · doi:10.1098/rsta.1948.0007 · Cited by 5,405
Block Copolymer Thermodynamics: Theory and Experiment
Bates, F. S., & Fredrickson, G. H. (1990) · Annual Review of Physical Chemistry · doi:10.1146/annurev.pc.41.100190.002521 · Cited by 3,960
Imprint Lithography with 25-Nanometer Resolution
Chou, S. Y., Krauss, P. R., & Renstrom, P. J. (1996) · Science · doi:10.1126/science.272.5258.85 · Cited by 2,277
Controlling polymer-surface interactions with random copolymer brushes
Mansky, P., Liu, Y., Huang, E., Russell, T. P., & Hawker, C. (1997) · Science · doi:10.1126/science.275.5305.1458 · Cited by 1,291
Heat Assisted Magnetic Recording
Kryder, M. H., Gage, E. C., McDaniel, T. W., Challener, W. A., Rottmayer, R. E., Ju, G., Hsia, Y.-T., & Erden, M. F. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.2004315 · Cited by 1,079
Nanofabricated and self-assembled magnetic structures as data storage media
Terris, B. D., & Thomson, T. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/12/r01 · Cited by 800
Macroscopic 10-terabit–per–square-inch arrays from block copolymers with lateral order
Park, S., Lee, D. H., Xu, J., Kim, B., Hong, S. W., Jeong, U., Xu, T., & Russell, T. P. (2009) · Science · doi:10.1126/science.1168108 · Cited by 740 · cited 2×
“First, using a higher χ BCP material, it is possible to achieve a full pitch even below 10 nm [57], [58].”
BackgroundMethodThe Feasibility of Magnetic Recording at 10 Terabits Per Square Inch on Conventional Media
Wood, R., Williams, M., Kavcic, A., & Miles, J. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2008.2010676 · Cited by 492
Neutron reflectivity studies of the surface-induced ordering of diblock copolymer films
Anastasiadis, S. H., Russell, T. P., Satija, S. K., & Majkrzak, C. F. (1989) · Physical Review Letters · doi:10.1103/physrevlett.62.1852 · Cited by 459
Cited by
Molecular Digital Data Storage Using DNA
Ceze, L., Nivala, J., & Strauss, K. (2019) · Nature Reviews Genetics · doi:10.1038/s41576-019-0125-3 · Cited by 551
Deciphering chemical order/disorder and material properties at the single-atom level
Yang, Y., Chen, C.-C., Scott, M. C., Ophus, C., Xu, R., Pryor, A., Wu, L., Sun, F., Theis, W., Zhou, J., et al. (2017) · Nature · doi:10.1038/nature21042 · Cited by 357
Nanoscale chemical imaging by photoinduced force microscopy
Nowak, D., Morrison, W., Wickramasinghe, H. K., Jahng, J., Potma, E., Wan, L., Ruiz, R., Albrecht, T. R., Schmidt, K., Frommer, J., et al. (2016) · Science Advances · doi:10.1126/sciadv.1501571 · Cited by 329
Self-citationD'Urso, M., & Kurniawan, N. A. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.609653 · Cited by 280
Frontiers of magnetic force microscopy
Kazakova, O., Puttock, R., Barton, C., Corte-León, H., Jaafar, M., Neu, V., & Asenjo, A. (2019) · Journal of Applied Physics · doi:10.1063/1.5050712 · Cited by 254
Metadata
- Authors
- Albrecht, T. R., Arora, H., Ayanoor-Vitikkate, V., Beaujour, J.-M., Bedau, D., Berman, D., Bogdanov, A. L., Chapuis, Y.-A., Cushen, J., Dobisz, E. E., Doerk, G., Gao, H., Grobis, M., Gurney, B., Hanson, W., Hellwig, O., Hirano, T., Jubert, P.-O., Kercher, D., Lille, J., Liu, Z., Mate, C. M., Obukhov, Y., Patel, K. C., Rubin, K., Ruiz, R., Schabes, M., Wan, L., Weller, D., Wu, T.-W., & Yang, E.
- Venue
- IEEE Transactions on Magnetics
- Published
- 2015-05
- Volume
- 51
- Issue
- 5
- Pages
- 1-42
- ISSN
- 0018-9464 (ISSN-L)
- 1941-0069
- OpenAlex
- W2029002794
- Cited by
- 398
- References
- 43
- FWCI
- 29.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.