Monitoring Breathing via Signal Strength in Wireless Networks
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This paper shows experimentally that standard wireless networks which measure received signal strength (RSS) can be used to reliably detect human breathing and estimate the breathing rate, an application we call “BreathTaking”. We present analysis showing that, as a first order approximation, breathing induces sinusoidal variation in the measured RSS on a link, with amplitude a function of the relative amplitude and phase of the breathing-affected multipath. We show that although an individual link may not reliably detect breathing, the collective spectral content of a network of devices reliably indicates the presence and rate of breathing. We present a maximum likelihood estimator (MLE) of breathing rate, amplitude, and phase, which uses the RSS data from many links simultaneously. We show experimental results which demonstrate that reliable detection and frequency estimation is possible with 30 seconds of data, within 0.07 to 0.42 breaths per minute (bpm) RMS error in several experiments. The experiments also indicate that the use of directional antennas may improve the systems robustness to external motion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cook, T. M., Woodall, N., & Frerk, C. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer058 · Cited by 2,415
Cook, T. M., Woodall, N., Harper, J., & Benger, J. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer059 · Cited by 1,065
Vgontzas, M., & Kales, M. (1999) · Annual Review of Medicine · doi:10.1146/annurev.med.50.1.387 · Cited by 227
Signal-to-Noise Ratio in Doppler Radar System for Heart and Respiratory Rate Measurements
Droitcour, A. D., Boric-Lubecke, O., & Kovacs, G. T. A. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2029668 · Cited by 162
Cited by
Wang, H., Zhang, D., Ma, J., Wang, Y., Wang, Y., Wu, D., Gu, T., & Xie, B. (2016) · Proceedings of the 2016 ACM International Joint Conference on Pervasive and Ubiquitous Computing · doi:10.1145/2971648.2971744 · Cited by 501
Wireless Sensing for Human Activity: A Survey
Liu, J., Liu, H., Chen, Y., Wang, Y., & Wang, C. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2019.2934489 · Cited by 414
“BreathTaking [132] model the breathing signals as sinusoidal waveforms and apply the maximum likelihood estimation (MLE) to estimate the breathing rate based on the RSSI measurements collected on around 20 wireless links.”
MethodNon-Invasive Detection of Moving and Stationary Human With WiFi
Wu, C., Yang, Z., Zhou, Z., Liu, X., Liu, Y., & Cao, J. (2015) · IEEE Journal on Selected Areas in Communications · doi:10.1109/jsac.2015.2430294 · Cited by 354
Contactless Sleep Apnea Detection on Smartphones
Nandakumar, R., Gollakota, S., & Watson, N. (2015) · Proceedings of the 13th Annual International Conference on Mobile Systems, Applications, and Services · doi:10.1145/2742647.2742674 · Cited by 343
Contactless Respiration Monitoring Via Off-the-Shelf WiFi Devices
Liu, X., Cao, J., Tang, S., Wen, J., & Guo, P. (2016) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2015.2504935 · Cited by 273
Metadata
- Authors
- Patwari, N., Wilson, J., Ananthanarayanan, S., Kasera, S. K., & Westenskow, D. R.
- Venue
- IEEE Transactions on Mobile Computing
- Published
- 2014-08
- Volume
- 13
- Issue
- 8
- Pages
- 1774-1786
- ISSN
- 1536-1233 (ISSN-L)
- OpenAlex
- W2952327846
- Cited by
- 128
- References
- 4
- FWCI
- 5.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.