Towards Low-Cost Sign Language Gesture Recognition Leveraging Wearables
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Different from traditional gestures, sign language gestures involve a lot of finger-level gestures without wrist or arm movements. They are hard to detect using existing motion sensors-based approaches. We introduce the first low-cost sign language gesture recognition system that can differentiate fine-grained finger movements using the Photoplethysmography (PPG) and motion sensors in commodity wearables. By leveraging the motion artifacts in PPG, our system can accurately recognize sign language gestures when there are large body movements, which cannot be handled by the traditional motion sensor-based approaches. We further explore the feasibility of using both PPG and motion sensors in wearables to improve the sign language gesture recognition accuracy when there are limited body movements. We develop a gradient boost tree (GBT) model and deep neural network-based model (i.e., ResNet) for classification. The transfer learning technique is applied to ResNet-based model to reduce the training effort. We develop a prototype using low-cost PPG and motions sensors and conduct extensive experiments and collect over 7000 gestures from 10 adults in the static and body-motion scenarios. Results demonstrate that our system can differentiate nine finger-level gestures from the American Sign Language with an average recognition accuracy over 98 percent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Deep learning for time series classification: a review
Ismail Fawaz, H., Forestier, G., Weber, J., Idoumghar, L., & Muller, P.-A. (2019) · Data Mining and Knowledge Discovery · doi:10.1007/s10618-019-00619-1 · Cited by 3,342 · cited 3×
“Those results prove that the ResNet as the fundamental multi-variate TSC is also suitable for our system, which not only provides the good performance without the procedure of extracting the features but also can take advantage of the transfer learning to significantly reduce the training effort to achieve decent perfo…”
MethodTime series classification from scratch with deep neural networks: A strong baseline
Wang, Z., Yan, W., & Oates, T. (2017) · 2017 International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2017.7966039 · Cited by 2,299 · cited 1×
“In this work, we especially adopt the deep Residual Network (ResNet) architecture proposed in [39], which provides excellent performance in both univariate and multivariate TSC [40].”
MethodWearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912 · cited 2×
“Such applications only focus on examining regular blood flow changing patterns in the radial artery and the ulnar artery and consider mechanical movement artifacts as noise [26].”
Background
Research works printed but not linked: 34
- 10.1016/j.patcog.2011.01.017 · DOI · Paper page
- 10.1109/TST.2014.6838194 · DOI · Paper page
- vuksanovic, 2013, Ar-based method for ecg classification and patient recognition, Int J Biometrics Bioinf, 7
- 10.4236/jbise.2011.411087 · DOI
- 10.1186/1476-7120-6-15 · DOI
- 10.1007/978-3-642-40811-3_66 · DOI · Paper page
- 10.18637/jss.v033.i01 · DOI · Paper page
- 10.1109/ICBME.2016.7890962 · DOI
- 10.1007/s00779-011-0395-z · doi:10.1007/s00779-011-0395-z
- 10.1109/THMS.2014.2302794 · DOI · Paper page
- 10.1145/2807442.2807480 · DOI · Paper page
- 10.1109/TSMCA.2011.2116004 · DOI · Paper page
- 10.1145/2699343.2699350 · DOI · Paper page
- 10.1145/2789168.2790121 · DOI · Paper page
- 10.1016/j.smhl.2019.100082 · DOI
- biagetti, 2017, Human activity recognition using accelerometer and photoplethysmographic signals, Proc Int Conf Intell Decision Technol, 53
- 10.1109/TMM.2014.2374357 · DOI · Paper page
- 10.1007/s11042-015-2451-6 · DOI · Paper page
- 10.1109/INFOCOM.2018.8486006 · DOI
- 10.1109/ICIP.2014.7025313 · DOI · Paper page
- 10.1109/TMM.2013.2246148 · DOI · Paper page
- 10.1145/2973750.2973755 · DOI · Paper page
- 10.1145/2789168.2790110 · DOI · Paper page
- 10.1145/2789168.2790129 · DOI · Paper page
- 10.1145/2858036.2858580 · DOI · Paper page
- 10.1109/ATSIP.2017.8075561 · DOI
- 10.1145/2500423.2500436 · DOI · Paper page
- 10.1109/INFOCOM.2015.7218525 · DOI · Paper page
- wang, 2016, Device-free gesture tracking using acoustic signals, Proc 22nd Annu Int Conf Mobile Comput Netw, 82
- 10.1145/2942358.2942393 · DOI · Paper page
- 10.1109/JSEN.2016.2581023 · DOI · Paper page
- 10.1145/2858036.2858466 · DOI · Paper page
- 10.1145/3081333.3081351 · DOI
- 10.1088/0967-3334/28/3/R01 · DOI · Paper page
Cited by
Qiu, S., Zhao, H., Jiang, N., Wang, Z., Liu, L., An, Y., Zhao, H., Miao, X., Liu, R., & Fortino, G. (2022) · Information Fusion · doi:10.1016/j.inffus.2021.11.006 · Cited by 671
Emerging Wearable Interfaces and Algorithms for Hand Gesture Recognition: A Survey
Jiang, S., Kang, P., Song, X., Lo, B., & Shull, P. (2022) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3078190 · Cited by 270
TS2ACT: Few-Shot Human Activity Sensing with Cross-Modal Co-Learning
Xia, K., Li, W., Gan, S., & Lu, S. (2023) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3631445 · Cited by 19
Intelligent Systems for Muscle Tracking: A Review on Sensor‐Algorithm Synergy
Putcha, A., Nguyen, T., Smith, R., Choffin, R., & Bai, W. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200351 · Cited by 10
Metadata
- Authors
- Zhao, T., Liu, J., Wang, Y., Liu, H., & Chen, Y.
- Venue
- IEEE Transactions on Mobile Computing
- Published
- 2021-04-01
- Volume
- 20
- Issue
- 4
- Pages
- 1685-1701
- ISSN
- 1536-1233 (ISSN-L)
- 1558-0660
- 2161-9875
- OpenAlex
- W2998454108
- Cited by
- 65
- References
- 4
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Funders
- National Science Foundation (CNS-1566455, CNS-1820624, CNS-1514436)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Towards Low-Cost Sign Language Gesture Recognition Leveraging Wearables. https://app.cochat.ai/papers/10.1109/tmc.2019.2962760
- The paper
- Zhao, T., Liu, J., Wang, Y., Liu, H., & Chen, Y. (2021). Towards Low-Cost Sign Language Gesture Recognition Leveraging Wearables. IEEE Transactions on Mobile Computing. https://doi.org/10.1109/tmc.2019.2962760
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.