The Use of Piezoelectric Ceramics for Electric Power Generation Within Orthopedic Implants
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper presents the results of tests that demonstrate the feasibility of using piezoelectric (PZT) ceramics to generate in vivo electrical energy for orthopedic implants. Sensors encapsulated within implants could provide in vivo diagnostic capabilities such as the monitoring of implant duty (i.e., walking) cycle, detecting abnormally asymmetric or high forces, sensing misalignment and early loosening, and early detection of wear. Early diagnosis of abnormalities or impending failure is critical to minimize patient harm. However, the routine use of sensors and microprocessors embedded within orthopedic implants for diagnostic and monitoring purposes has been limited by the lack of a long-term self-contained power source capable of lasting the expected 20-year implant lifetimes. By embedding PZT materials within orthopedic implants, a small amount of the mechanical energy generated during normal physical activity can be converted into useful electrical energy. This in vivo energy source can power embedded microprocessors and sensors for a broad range of biomedical uses. The current work investigates the application of this technology to total knee replacement (TKR) implants, but it is applicable to many other implanted biomedical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human-powered wearable computing
Starner, T. (1996) · IBM Systems Journal · doi:10.1147/sj.353.0618 · Cited by 876 · cited 1×
“human walking at a rate of two steps per second [24].”
Background
Cited by
Energy harvesting vibration sources for microsystems applications
Beeby, S. P., Tudor, M. J., & White, N. M. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/12/r01 · Cited by 3,008
“The generation of power by positioning piezoelectric inserts within orthopaedic implants has been studied by Platt et al [52].”
BackgroundA review of power harvesting using piezoelectric materials (2003–2006)
Anton, S. R., & Sodano, H. A. (2007) · Smart Materials and Structures · doi:10.1088/0964-1726/16/3/r01 · Cited by 2,652
Energy harvesting in wireless sensor networks: A comprehensive review
Shaikh, F. K., & Zeadally, S. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.11.010 · Cited by 1,253
Cook-Chennault, K. A., Thambi, N., & Sastry, A. M. (2008) · Smart Materials and Structures · doi:10.1088/0964-1726/17/4/043001 · Cited by 1,241
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
Liu, H., Zhong, J., Lee, C., Lee, S.-W., & Lin, L. (2018) · Applied Physics Reviews · doi:10.1063/1.5074184 · Cited by 905
Radial-arrayed rotary electrification for high performance triboelectric generator
Zhu, G., Chen, J., Zhang, T., Jing, Q., & Wang, Z. L. (2014) · Nature Communications · doi:10.1038/ncomms4426 · Cited by 868
Flexible High-Output Nanogenerator Based on Lateral ZnO Nanowire Array
Zhu, G., Yang, R., Wang, S., & Wang, Z. L. (2010) · Nano Letters · doi:10.1021/nl101973h · Cited by 805
Energy harvesting from low frequency applications using piezoelectric materials
Li, H., Tian, C., & Deng, Z. D. (2014) · Applied Physics Reviews · doi:10.1063/1.4900845 · Cited by 705
In Vivo Powering of Pacemaker by Breathing‐Driven Implanted Triboelectric Nanogenerator
Zheng, Q., Shi, B., Fan, F., Wang, X., Yan, L., Yuan, W., Wang, S., Liu, H., Li, Z., & Wang, Z. L. (2014) · Advanced Materials · doi:10.1002/adma.201402064 · Cited by 603
Recent Progress on Piezoelectric and Triboelectric Energy Harvesters in Biomedical Systems
Zheng, Q., Shi, B., Li, Z., & Wang, Z. L. (2017) · Advanced Science · doi:10.1002/advs.201700029 · Cited by 566
A survey of energy harvesting sources for embedded systems
Chalasani, S., & Conrad, J. M. (2008) · IEEE SoutheastCon 2008 · doi:10.1109/secon.2008.4494336 · Cited by 482
Muscle‐Driven In Vivo Nanogenerator
Li, Z., Zhu, G., Yang, R., Wang, A. C., & Wang, Z. L. (2010) · Advanced Materials · doi:10.1002/adma.200904355 · Cited by 441
Power Approaches for Implantable Medical Devices
Amar, A., Kouki, A., & Cao, H. (2015) · Sensors · doi:10.3390/s151128889 · Cited by 432
Group III nitride and SiC based MEMS and NEMS: materials properties, technology and applications
Cimalla, V, Pezoldt, J., & Ambacher, O. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/20/s19 · Cited by 392
Electrical stimulation and piezoelectric biomaterials for bone tissue engineering applications.
Khare, D., Basu, B., & Dubey, A. K. (2020) · PubMed · doi:10.1016/j.biomaterials.2020.120280 · Cited by 354
Energy harvesting for the implantable biomedical devices: issues and challenges
Hannan, M. A., Mutashar, S., Samad, S. A., & Hussain, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-79 · Cited by 322
Piezoelectric energy harvesters for biomedical applications
Ali, F., Raza, W., Li, X., Gul, H., & Kim, K.-H. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.01.012 · Cited by 300
On Low-Frequency Electric Power Generation With PZT Ceramics
Platt, S. R., Farritor, S., & Haider, H. (2005) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2005.844704 · Cited by 294
Self-citationRecent Advances in Intelligent Wearable Medical Devices Integrating Biosensing and Drug Delivery
Tan, M., Xu, Y., Gao, Z., Yuan, T., Liu, Q., Yang, R., Zhang, B., & Peng, L. (2022) · Advanced Materials · doi:10.1002/adma.202108491 · Cited by 187
Hou, H., Xu, Q., Pang, Y., Li, L., Wang, J., Zhang, C., & Sun, C. (2017) · Advanced Science · doi:10.1002/advs.201700072 · Cited by 170
Energy scavenging sources for biomedical sensors
Romero, E., Warrington, R. O., & Neuman, M. R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/9/r01 · Cited by 165
Cadei, A., Dionisi, A., Sardini, E., & Serpelloni, M. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/25/1/012003 · Cited by 158
“Platt et al in [41, 42] use piezoelectric ceramics”
Wireless technologies for implantable devices
Nelson, B. D., Karipott, S. S., Wang, Y., & Ong, K. G. (2020) · Sensors · doi:10.3390/s20164604 · Cited by 125
“There are many wearable piezoelectric energy harvesters that use forces that occur during ambulation [77], and some implants use a similar approach at joint interfaces [74].”
BackgroundDesigning and manufacturing a piezoelectric tile for harvesting energy from footsteps
Hwang, S. J., Jung, H. J., Kim, J. H., Ahn, J. H., Song, D., Song, Y., Lee, H. L., Moon, S. P., Park, H., & Sung, T. H. (2015) · Current Applied Physics · doi:10.1016/j.cap.2015.02.009 · Cited by 92
Almouahed, S., Gouriou, M., Hamitouche, C., Stindel, E., & Roux, C. (2011) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2159512 · Cited by 59
“This active area has not been taken into account when modeling the piezoelectric element in [7] and [8].”
BackgroundMethodResultInfluentialAnalysis of the energy extracted by a harvester based on a piezoelectric tile
Cascetta, F., Lo Schiavo, A., Minardo, A., Musto, M., Rotondo, G., & Calcagni, A. (2018) · Current Applied Physics · doi:10.1016/j.cap.2018.04.015 · Cited by 20
Metadata
- Authors
- Platt, S. R., Farritor, S., Garvin, K., & Haider, H.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2005-08
- Volume
- 10
- Issue
- 4
- Pages
- 455-461
- ISSN
- 1083-4435 (ISSN-L)
- OpenAlex
- W2100725179
- Cited by
- 232
- References
- 1
- FWCI
- 12.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.