The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Design of a haptic arm exoskeleton for training and rehabilitation
Abstract
A high-quality haptic interface is typically characterized by low apparent inertia and damping, high structural stiffness, minimal backlash, and absence of mechanical singularities in the workspace. In addition to these specifications, exoskeleton haptic interface design involves consideration of space and weight limitations, workspace requirements, and the kinematic constraints placed on the device by the human arm. These constraints impose conflicting design requirements on the engineer attempting to design an arm exoskeleton. In this paper, the authors present a detailed review of the requirements and constraints that are involved in the design of a high-quality haptic arm exoskeleton. In this context, the design of a five-degree-of-freedom haptic arm exoskeleton for training and rehabilitation in virtual environments is presented. The device is capable of providing kinesthetic feedback to the joints of the lower arm and wrist of the operator, and will be used in future work for robot-assisted rehabilitation and training. Motivation for such applications is based on findings that show robot-assisted physical therapy aids in the rehabilitation process following neurological injuries. As a training tool, the device provides a means to implement flexible, repeatable, and safe training methodologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Manipulability of Robotic Mechanisms
Yoshikawa, T. (1985) · The International Journal of Robotics Research · doi:10.1177/027836498500400201 · Cited by 2,582
Force and Touch Feedback for Virtual Reality
Burdea, G. (1996) · Cited by 1,019
Motor rehabilitation using virtual reality
Sveistrup, H. (2004) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-1-10 · Cited by 745
Virtual reality-enhanced stroke rehabilitation
Jack, D., Boian, R., Merians, A. S., Tremaine, M., Burdea, G. C., Adamovich, S. V., Recce, M., & Poizner, H. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.948460 · Cited by 733
Factors affecting the Z-Width of a haptic display
Colgate, J. E., & Brown, J. M. (2002) · Proceedings of the 1994 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1994.351077 · Cited by 635
Virtual fixtures: Perceptual tools for telerobotic manipulation
Rosenberg, L. B. (1993) · Proceedings of IEEE Virtual Reality Annual International Symposium · doi:10.1109/vrais.1993.380795 · Cited by 578
Dynamic analysis of a three-degrees-of-freedom in-parallel actuated manipulator
Lee, K.-M., & Shah, D. K. (1988) · IEEE Journal on Robotics and Automation · doi:10.1109/56.797 · Cited by 446
A myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437
Haptic guidance: experimental evaluation of a haptic training method for a perceptual motor skill
Feygin, D., Keehner, M., & Tendick, R. (2003) · Proceedings 10th Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. HAPTICS 2002 · doi:10.1109/haptic.2002.998939 · Cited by 394
Kinematic analysis of a three-degrees-of-freedom in-parallel actuated manipulator
Lee, K.-M., & Shah, D. K. (1988) · IEEE Journal on Robotics and Automation · doi:10.1109/56.796 · Cited by 331
Augmented Feedback Presented in a Virtual Environment Accelerates Learning of a Difficult Motor Task
Todorov, E., Shadmehr, R., & Bizzi, E. (1997) · Journal of Motor Behavior · doi:10.1080/00222899709600829 · Cited by 314
Basdogan, C., Ho, C.-H., & Srinivasan, M. A. (2001) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/3516.951365 · Cited by 278
An arm exoskeleton system for teleoperation and virtual environments applications
Bergamasco, M., Allotta, B., Bosio, L., Ferretti, L., Parrini, G., Prisco, G. M., Salsedo, F., & Sartini, G. (2002) · Proceedings of the 1994 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1994.351286 · Cited by 196
Recent Developments and Applications of Haptic Devices
Laycock, S. D., & Day, A. M. (2003) · Computer Graphics Forum · doi:10.1111/1467-8659.00654 · Cited by 149
The dynamics and control of a haptic interface device
Kazerooni, H., & Her, M.-G. (1994) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.313096 · Cited by 115
A 7 DOF pneumatic muscle actuator (pMA) powered exoskeleton
Tsagarakis, N. G., Caldwell, D. G., & Medrano‐Cerda, G. A. (2003) · IEEE RO-MAN · doi:10.1109/roman.1999.900361 · Cited by 103
Wiseman, P. (1998) · bepress Legal Repository · Cited by 103
A Force Reflected Exoskeleton-Type Masterarm for Human–Robot Interaction
Kim, Y. S., Lee, J., Lee, S., et al. (2005) · IEEE Transactions on Systems Man and Cybernetics - Part A Systems and Humans · doi:10.1109/tsmca.2004.832836 · Cited by 64
Finger Force and Touch Feedback Issues in Dexterous Telemanipulation
Shimoga, K. B. (2005) · Annual Conference on Intelligent Robotic Systems for Space Exploration · doi:10.1109/irsse.1992.671841 · Cited by 63
The effect of force saturation on the haptic perception of detail
O’Malley, M. K., & Goldfarb, M. T. (2002) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2002.802725 · Cited by 51
Self-citationA virtual environment with haptic feedback for the treatment of motor dexterity disabilities
Prisco, G. M., Avizzano, C. A., Calcara, M., Ciancio, S., Pinna, S., & Bergamasco, M. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1998.681418 · Cited by 34
Kiguchi, K., & Fukuda, T. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2004.1307424 · Cited by 33
Passive and active assistance for human performance of a simulated underactuated dynamic task
O’Malley, M. K., & Gupta, A. K. (2003) · Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems · doi:10.1109/haptic.2003.1191308 · Cited by 28
Self-citationShared Control for Upper Extremity Rehabilitation in Virtual Environments
O’Malley, M. K. (2005) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2005-81782 · Cited by 2
Self-citation
Cited by
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
Developments in hardware systems of active upper-limb exoskeleton robots: A review
Gopura, R. A. R. C., Bandara, D. S. V., Kiguchi, K., & Mann, G. K. I. (2016) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2015.10.001 · Cited by 480
Losey, D. P., McDonald, C. G., Battaglia, E., & O'Malley, M. K. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4039145 · Cited by 392
Self-citationUpper-Limb Robotic Exoskeletons for Neurorehabilitation: A Review on Control Strategies
Proietti, T., Crocher, V., Roby-Brami, A., & Jarrasse, N. (2016) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2016.2552201 · Cited by 388
Active Exoskeleton Control Systems: State of the Art
Anam, K., & Al-Jumaily, A. A. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.07.273 · Cited by 304
Metadata
- Authors
- Gupta, A., & O'Malley, M. K.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2006-06
- Volume
- 11
- Issue
- 3
- Pages
- 280-289
- ISSN
- 1083-4435 (ISSN-L)
- OpenAlex
- W2106383691
- Cited by
- 328
- References
- 24
- FWCI
- 10.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.