The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Control of Rotary Series Elastic Actuator for Ideal Force-Mode Actuation in Human–Robot Interaction Applications
Abstract
To realize ideal force control of robots that interact with a human, a very precise actuating system with zero impedance is desired. For such applications, a rotary series elastic actuator (RSEA) has been introduced recently. This paper presents the design of RSEA and the associated control algorithms. To generate joint torque as desired, a torsional spring is installed between a motor and a human joint, and the motor is controlled to produce a proper spring deflection for torque generation. When the desired torque is zero, the motor must follow the human joint motion, which requires that the friction and the inertia of the motor be compensated. The human joint and the body part impose the load on the RSEA. They interact with uncertain environments and their physical properties vary with time. In this paper, the disturbance observer (DOB) method is applied to make the RSEA precisely generate the desired torque under such time-varying conditions. Based on the nominal model preserved by the DOB, feedback and feedforward controllers are optimally designed for the desired performance, i.e., the RSEA: (1) exhibits very low impedance and (2) generates the desired torque precisely while interacting with a human. The effectiveness of the proposed design is verified by experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impedance Control: An Approach to Manipulation: Part I—Theory
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140702 · Cited by 3,673
Pratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206
Shigley, J. E. (2001) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,157
Electroactive polymer (EAP) actuators as artificial muscles : reality, potential, and challenges
Bar‐Cohen, Y. (2001) · Medical Entomology and Zoology · Cited by 1,177
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
Patient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729
(2004) · SPIE eBooks · doi:10.1117/3.547465 · Cited by 677
On the Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Racine, J.-L., Huang, L., & Steger, R. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570790 · Cited by 594
Robust motion controller design for high-accuracy positioning systems
Lee, H. S., & Tomizuka, M. (1996) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.481407 · Cited by 436
Self-citationSeries elastic actuator development for a biomimetic walking robot
Robinson, D. W., Pratt, J. E., Paluska, D. J., & Pratt, G. A. (1999) · 1999 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (Cat. No.99TH8399) · doi:10.1109/aim.1999.803231 · Cited by 409
Design and control of an exoskeleton for the elderly and patients
Kong, K., & Jeon, D. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.878550 · Cited by 403
Self-citationHayashi, T., Kawamoto, H., & Sankai, Y. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545505 · Cited by 377
Series elastic actuators for high fidelity force control
Pratt, J., Krupp, B., & Morse, C. (2002) · Industrial Robot: An International Journal · doi:10.1108/01439910210425522 · Cited by 343
Complementary Stability and Loop Shaping for Improved Human–Robot Interaction
Buerger, S. P., & Hogan, N. (2007) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.892229 · Cited by 269
Impedance Control:An Approach to Manipulation,Parts I,II,III
Hogan, N. (1985) · Medical Entomology and Zoology · Cited by 254
Application of rubber artificial muscle manipulator as a rehabilitation robot
Noritsugu, T., & Tanaka, T. (1997) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/3516.653050 · Cited by 243
Analysis and experimental validation of force bandwidth for force control
Katsura, S., Matsumoto, Y., & Ohnishi, K. (2004) · IEEE International Conference on Industrial Technology, 2003 · doi:10.1109/icit.2003.1290759 · Cited by 207
Analysis and experimental validation of force bandwidth for force control
Katsura, S., Matsumoto, Y., & Ohnishi, K. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.874262 · Cited by 200
Gravity-Balancing Leg Orthosis and Its Performance Evaluation
Banala, S. K., Agrawal, S. K., Fattah, A., Krishnamoorthy, V., Hsu, W.-L., Scholz, J., & Rudolph, K. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2006.882928 · Cited by 199
Design and Characterization of Hand Module for Whole-Arm Rehabilitation Following Stroke
Masia, L., Krebs, H. I., Cappa, P., & Hogan, N. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.901928 · Cited by 124
Stand alone wearable power assisting suit - sensing and control systems
Yamamoto, K., Ishii, M., Noborisaka, H., & Hyodo, K. (2005) · IEEE RO-MAN · doi:10.1109/roman.2004.1374841 · Cited by 106
Smooth and continuous human gait phase detection based on foot pressure patterns
Kong, K., & Tomizuka, M. (2008) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2008.4543775 · Cited by 95
Self-citation
Cited by
Developments in hardware systems of active upper-limb exoskeleton robots: A review
Gopura, R. A. R. C., Bandara, D. S. V., Kiguchi, K., & Mann, G. K. I. (2016) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2015.10.001 · Cited by 480
Design and Control Considerations for High-Performance Series Elastic Actuators
Paine, N., Oh, S., & Sentis, L. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2270435 · Cited by 405
Human–Robot Interaction Control of Rehabilitation Robots With Series Elastic Actuators
Yu, H., Huang, S., Chen, G., Pan, Y., & Guo, Z. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2457314 · Cited by 356
A Review of Algorithms for Compliant Control of Stiff and Fixed-Compliance Robots
Calanca, A., Muradore, R., & Fiorini, P. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2465849 · Cited by 320
Kim, B., & Deshpande, A. D. (2017) · The International Journal of Robotics Research · doi:10.1177/0278364917706743 · Cited by 309
Metadata
- Authors
- Kong, K., Bae, J., & Tomizuka, M.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2009-02
- Volume
- 14
- Issue
- 1
- Pages
- 105-118
- ISSN
- 1083-4435 (ISSN-L)
- OpenAlex
- W2166230296
- Cited by
- 426
- References
- 23
- FWCI
- 37.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.