Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 301

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

A Gait Monitoring System Based on Air Pressure Sensors Embedded in a Shoe

Kyoungchul Kong, Tomizuka, M.·2009·IEEE/ASME Transactions on Mechatronics

Abstract

Measurement of ground contact forces (GCFs) provides necessary information to detect human gait phases. In this paper, a new analysis method of the GCF signals is discussed for detection of the gait phases. Human gaits are complicated, and the gait phases cannot be exactly distinguished by comparing sensor outputs to a threshold. This paper proposes a method by fuzzy logic for detecting the gait phases continuously and smoothly. The smooth and continuous detection of the gait phases enables a full use of information obtained from GCF sensors. For advanced rehabilitation systems, this paper also introduces a higher level algorithm that quantitatively monitors the amount of abnormalities in a human gait. The abnormalities detected by the proposed method include an improper GCF pattern as well as an incorrect sequence of the gait phases. To realize the monitoring algorithm, the gait phases are analyzed as a vector and the abnormalities are detected by simple kinematic equations. The proposed methods are implemented by using signals from sensor-embedded shoes called smart shoes. Each smart shoe has four GCF sensors installed between the cushion pad and the sole. The GCF sensor applies an air pressure sensor connected to an air bladder. A gait monitoring system that integrates the proposed methods is shown in this paper and verified for both normal and abnormal gaits.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmech.2008.2008803

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 301

Metadata

Authors
Kong, K., & Tomizuka, M.
Venue
IEEE/ASME Transactions on Mechatronics
Published
2009-06
Volume
14
Issue
3
Pages
358-370
ISSN
  • 1083-4435 (ISSN-L)
  • 1941-014X
OpenAlex
W2047993060
Cited by
301
References
13
FWCI
8.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Gait Monitoring System Based on Air Pressure Sensors Embedded in a Shoe. https://app.cochat.ai/papers/10.1109/tmech.2008.2008803
The paper
Kong, K., & Tomizuka, M. (2009). A Gait Monitoring System Based on Air Pressure Sensors Embedded in a Shoe. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2008.2008803

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.