Design of a Multifunctional Anthropomorphic Prosthetic Hand With Extrinsic Actuation
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
This paper presents an anthropomorphic prototype hand prosthesis that is intended for use with a multiple-channel myoelectric interface. The hand contains 16 joints, which are differentially driven by a set of five independent actuators. The hand prototype was designed with the minimum number of independent actuators required to provide a set of eight canonical hand postures. This paper describes the design of the prosthesis prototype, demonstrates the hand in the desired eight canonical postures, and experimentally characterizes the force and speed capability of the device. A video is included in the supplementary material that also illustrates the functionality and performance of the hand.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In these devices, cables in the forms of variable length tendons are embedded in soft or rigid skeletons to provide a controlled deformation.[482,483]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [482]
Citations
Cites
On grasp choice, grasp models, and the design of hands for manufacturing tasks
Cutkosky, M. R. (1989) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.34763 · Cited by 1,513 · cited 3×
“These grasps are a superset of the six basic types of prehension, as identified by Schlesinger and summarized by Taylor and Schwarz [11] (where the tripod grasp is considered a “palmar” grasp), and represent each branch of the grasp taxonomy described by Cutkosky [12].”
BackgroundJones, L. A., & Lederman, S. J. (2006) · doi:10.1093/acprof:oso/9780195173154.001.0001 · Cited by 720
Robust control of dynamically interacting systems
COLGATE, J. E., & HOGAN, N. (1988) · International Journal of Control · doi:10.1080/00207178808906161 · Cited by 589 · cited 1×
“, stiff objects in the environment) relative to velocity-controlled, nonbackdrivable systems [16].”
BackgroundEpidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
Zollo, L., Roccella, S., Guglielmelli, E., Carrozza, M. C., & Dario, P. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.901936 · Cited by 335 · cited 1×
“Such joint compliance has been employed in several previous hand designs for this purpose [6], [7].”
MethodThe anatomy and mechanics of the human hand.
TAYLOR, C. L., & SCHWARZ, R. J. (1955) · PubMed · Cited by 311
Development of a lightweight and adaptable multiple-axis hand prosthesis
Light, C. M., & Chappell, P. H. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00017-0 · Cited by 178 · cited 1×
“Several prosthetic hands have recently been described in engineering research papers [3]–[10].”
BackgroundImproved Myoelectric Prosthesis Control Using Targeted Reinnervation Surgery: A Case Series
Miller, L. A., Stubblefield, K. A., Lipschutz, R. D., Lock, B. A., & Kuiken, T. A. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.911817 · Cited by 157 · cited 1×
“The approach described in [1], which utilizes “targeted reinnervation” of peripheral nerves into resid-”
MethodMyoelectric prostheses. A long-term follow-up and a study of the use of alternate prostheses.
Silcox, D. H., Rooks, M. D., Vogel, R. R., & Fleming, L. L. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199312000-00007 · Cited by 144 · cited 1×
“Note that surveys of prosthetic users [8], [13]–[15] offer the following as important factors in the performance of a prosthetic”
BackgroundControl of a Six Degree of Freedom Prosthetic Arm After Targeted Muscle Reinnervation Surgery
Miller, L. A., Lipschutz, R. D., Stubblefield, K. A., Lock, B. A., Huang, H., Williams, T. W., Weir, R. F., & Kuiken, T. A. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.05.016 · Cited by 119 · cited 3×
“ual muscle sites, has been shown to provide control input for devices with as many as six DOFs [2].”
BackgroundInfluential
Research works printed but not linked: 1
- weir, 2003, Standard Handbook of Biomedical Engineering & Design, 32 1
Cited by
Items 201–203 of 203
Shahmohammadi, M., Guan, B., & Liarokapis, M. V. (2022) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc53654.2022.9945582
Design of a hybrid-actuated finger prosthesis with tactile sensing
Low, C. Y., Kasim, M. A. A., Mansur, M. F. A., Jaffar, A. M., Ng, K. M., & Koch, T. (2012) · International Conference on Electronics, Hardware, Wireless and Optical Communications
Bharadwaj, D., 안인균, S.Deshmukh, S., & Kang, J. (2026) · Healthcare Technology Letters · doi:10.1049/htl2.70092
Metadata
- Authors
- Dalley, S. A., Wiste, T. E., Withrow, T. J., & Goldfarb, M.
- Affiliations
- Vanderbilt University (US)
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2009-12
- Volume
- 14
- Issue
- 6
- Pages
- 699-706
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2054098571
- Semantic Scholar
- 1336d57e7bc711460d689d7076617eba703f41f7
- Cited by
- 204
- References
- 18
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 2 · 2023: 6 · 2022: 11 · 2021: 17 · 2020: 9 · 2019: 19 · 2018: 12 · 2017: 16 · 2016: 21 · 2015: 12 · 2014: 22 · 2013: 17 · 2012: 12
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE/ASME Transactions on Mechatronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Keywords
- myoelectric control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.