Adaptive Suppression of Severe Pathological Tremor by Torque Estimation Method
Abstract
Tremor is a rhythmical and involuntary oscillatory movement of a body part. In addition to social embarrassment, tremor can be debilitating for daily activities. Recently, wearable active exoskeletons emerged as a noninvasive tremor suppression alternative to medication or surgery. The challenge in musculoskeletal tremor suppression is identifying and attenuating the tremor motion without adding resistance to the patient's intentional motion. In this research, an adaptive tremor suppression algorithm was designed to estimate the tremor fundamental frequency and calculate the proper suppressive force to be applied by the orthosis to the patient's arm. Stability of the closed-loop system and robustness against the parametric uncertainties were analyzed. An experimental setup was designed and developed to emulate the dynamics of a human wrist with intentional and tremor motion. A pneumatic cylinder and a sliding mode integral controller was used to apply orthotic suppressive force. The algorithm was implemented with an NI cRIO real-time controller and tested using clinical data from ten patients with severe pathological tremor. Experimental results showed tracking of the tremor frequency with less than 3-s response time, and an average 34.5 dB (98.1%) and 11.8 dB (74.3%) reduction of tremor amplitude at the fundamental and second-harmonic frequencies, respectively. The average resistance force to the intentional motion was 0.7 N and the average position error was 2.08% (0.18 dB). The results were compared with passive tremor suppression using a tunable magnetorheological damper.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The remaining systems focused on design or experimental testing whereby the human motion (tremor and voluntary) was simulated physically or in software [4, 16, 22–26, 33–35].”
From Controlling a motorized orthosis to follow elbow volitional movement: tests with individuals with pathological tremor (2019) · cites this paper as [26]
In the citing paper
“A study by Taheri et al. reported the actuator resistive forces to the voluntary motions in a tremor simulation system [26].”
From Controlling a motorized orthosis to follow elbow volitional movement: tests with individuals with pathological tremor (2019) · cites this paper as [26]
In the citing paper
“ET and PD frequencies are considered to be in the range of 4–12 and 4–6 Hz, respectively, while ADL tend to be in the range of 0–2 Hz (Mann et al., 1989; Wyne, 2005; Taheri et al., 2015).”
From Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression (2016) · cites this paper as Taheri et al., 2015
In the citing paper
“Our studying of the first two tremor harmonics was based on a finding reported by Taheri et al. (2015) where it was shown that the first two harmonics contain the majority (above 94%) of the signal power.”
From Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression (2016) · cites this paper as Taheri et al. (2015)
In the citing paper
“The average position error on the voluntary movement was 2.08%.”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [57]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981
A High Performance Pneumatic Force Actuator System: Part I—Nonlinear Mathematical Model
Richer, E., & Hurmuzlu, Y. (2000) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.1286336 · Cited by 485
Self-citationTreatment of patients with essential tremor
Deuschl, G., Raethjen, J., Hellriegel, H., & Elble, R. (2011) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70322-7 · Cited by 428 · cited 1×
“of patients do not respond to the treatment or the positive effects are temporary [3]–[5].”
BackgroundGomi, H., & Osu, R. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-21-08965.1998 · Cited by 352 · cited 1×
“The scalar parameters κ and β are not constant as shown in numerous studies [25], [26].”
ResultDesign and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349 · cited 2×
“tremor suppression, as has been previously proposed [9], [10], [12], [19].”
BackgroundElble, R. J. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199603000-00004 · Cited by 271 · cited 1×
“It primarily influences hand motion, though it can affect the head, face, and trunk [29].”
BackgroundHuman arm stiffness characteristics during the maintenance of posture
Flash, T., & Mussa-Ivaldi, F. (1990) · Experimental Brain Research · doi:10.1007/bf00231251 · Cited by 257 · cited 2×
“this cannot happen, since the joint stiffness and damping are positively correlated [40]–[42].”
BackgroundThe pathophysiology of parkinsonian tremor: a review
Deuschl, G., Raethjen, J., Baron, R., Lindemann, M., Wilms, H., & Krack, P. (2000) · Journal of Neurology · doi:10.1007/pl00007781 · Cited by 251 · cited 1×
“of patients do not respond to the treatment or the positive effects are temporary [3]–[5].”
BackgroundClinical Neurophysiology of Tremor
Deuschl, G., Krack, P., Lauk, M., & Timmer, J. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199603000-00002 · Cited by 210 · cited 1×
“is mostly postural and kinetic tremor (action tremor) [1], [2].”
BackgroundTime-Domain Signal Analysis Using Adaptive Notch Filter
Mojiri, M., Karimi-Ghartemani, M., & Bakhshai, A. (2007) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2006.885686 · Cited by 180 · cited 1×
“where ξe1 , ξe2 , and ξe3 are the states of the estimator, ωT (t) is the estimated tremor fundamental frequency, and ζe and γ govern the speed of convergence and the performance of the frequency estimator [34].”
BackgroundImpedance characteristics of a neuromusculoskeletal model of the human arm I. Posture control
Stroeve, S. (1999) · Biological Cybernetics · doi:10.1007/s004220050577 · Cited by 172 · cited 2×
“this cannot happen, since the joint stiffness and damping are positively correlated [40]–[42].”
BackgroundSoft Mobile Robots with On-Board Chemical Pressure Generation
Onal, C. D., Chen, X., Whitesides, G. M., & Rus, D. (2017) · Springer Tracts in Advanced Robotics · doi:10.1007/978-3-319-29363-9_30 · Cited by 171
Essential tremor frequency decreases with time
Elble, R. J. (2000) · Neurology · doi:10.1212/wnl.55.10.1547 · Cited by 166 · cited 1×
“tremor frequency in the case of ET and PT decreases with the progression of the disease; however, the reduction is not linear [32], [33].”
BackgroundA model of force and impedance in human arm movements
Tee, K. P., Burdet, E., Chew, C. M., & Milner, T. E. (2004) · Biological Cybernetics · doi:10.1007/s00422-004-0484-4 · Cited by 164 · cited 2×
“The scalar parameters κ and β are not constant as shown in numerous studies [25], [26].”
ResultAttenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150 · cited 1×
“Functional electrical stimulation has been used to stimulate the tremorogenic muscles and attenuate tremor amplitude [6]–[8].”
MethodPathological tremors: deterministic chaos or nonlinear stochastic oscillators?
Timmer, J., Häussler, S., Lauk, M., & Lücking, C.-H. (2000) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.166494 · Cited by 130
Electrical stimulation for the suppression of pathological tremor
Popović Maneski, L., Jorgovanović, N., Ilić, V., Došen, S., Keller, T., Popović, M. B., & Popović, D. B. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0803-6 · Cited by 129 · cited 1×
“Functional electrical stimulation has been used to stimulate the tremorogenic muscles and attenuate tremor amplitude [6]–[8].”
MethodFrequency spectrum analysis of wrist motion for activities of daily living
Mann, K. A., Wernere, F. W., & Palmer, A. K. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070219 · Cited by 107 · cited 1×
“The intentional motion torque, τI , contains components in the frequency range of 0–2 Hz, typical for the majority of daily tasks [10], [30], [39].”
BackgroundDesign and Characterization of a Small-Scale Magnetorheological Damper for Tremor Suppression
Case, D., Taheri, B., & Richer, E. (2011) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2151204 · Cited by 101
Self-citation(1998) · PubMed · Cited by 101
Force and Stiffness Backstepping-Sliding Mode Controller for Pneumatic Cylinders
Taheri, B., Case, D., & Richer, E. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2294970 · Cited by 92
Self-citationPathological tremor management: modelling, compensatory technology and evaluation
Rocon, E., Belda-Lois, J. M., Sanchez-Lacuesta, J. J., & Pons, J. L. (2004) · Technology and Disability · doi:10.3233/tad-2004-16102 · Cited by 89 · cited 2×
“In most cases, PT amplitude decreases with voluntary muscle contraction with a residual mild to moderate action tremor [1], [30].”
BackgroundTremor suppression through impedance control
Pledgie, S., Barner, K. E., Agrawal, S. K., & Rahman, T. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.830949 · Cited by 85 · cited 1×
“employed impedance control and a PHANToM manipulator to change the frequency response of the human–machine system such that the closed-loop system has a higher impedance in the high-frequency region [16].”
MethodAdaptive Fourier modeling for quantification of tremor
Riviere, C. N., Reich, S. G., & Thakor, N. V. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02263-2 · Cited by 83 · cited 1×
“based on the tremorous motion estimated by the weighted Fourier linear combiner (WFLC) filter [17], [18].”
MethodA Gas-Actuated Anthropomorphic Prosthesis for Transhumeral Amputees
Fite, K. B., Withrow, T. J., Shen, X., Wait, K. W., Mitchell, J. E., & Goldfarb, M. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.914845 · Cited by 82 · cited 1×
“The orthosis will be powered using high-pressure CO2 canisters [43] or by a pneumatic battery [44], [45].”
MethodCharacterizing the Human Wrist for Improved Haptic Interaction
Kuchenbecker, K. J., Park, J. G., & Niemeyer, G. (2003) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2003-42017 · Cited by 82 · cited 3×
“subjects for the inertia, damping, and stiffness for the elbow and wrist joints based on a linearized dynamic model are presented in [23] and [27].”
BackgroundMethodLoureiro, R. C. V., Belda-Lois, J. M., Lima, E. R., Pons, J. L., Sanchez-Lacuesta, J. J., & Harwin, W. S. (2005) · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. · doi:10.1109/icorr.2005.1501065 · Cited by 70
Mechanical suppression of essential tremor
Rocon, E., Manto, M., Pons, J., Camut, S., & Belda, J. M. (2007) · The Cerebellum · doi:10.1080/14734220601103037 · Cited by 68 · cited 4×
“to the characteristics of the patient’s tremor [10], [19].”
BackgroundInfluentialRobust Controller for Tremor Suppression at Musculoskeletal Level in Human Wrist
Taheri, B., Case, D., & Richer, E. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2295034 · Cited by 66 · cited 1×
“An alternative strategy employed a robust stabilizer designed based on the backstepping technique [21].”
MethodSelf-citationA longitudinal study of tremor frequencies in Parkinson’s disease and essential tremor
Hellwig, B., Mund, P., Schelter, B., Guschlbauer, B., Timmer, J., & Lücking, C. H. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.11.002 · Cited by 65 · cited 1×
“tremor frequency in the case of ET and PT decreases with the progression of the disease; however, the reduction is not linear [32], [33].”
Background(1995) · PubMed · Cited by 63
Gillard, D. M., Cameron, T., Prochazka, A., & Gauthier, M. J. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788474 · Cited by 61
Dynamical Modeling and Experimental Study of a Small-Scale Magnetorheological Damper
Case, D., Taheri, B., & Richer, E. (2013) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2265701 · Cited by 57 · cited 2×
“energy consumption but can produce only resistive force and are thus prone to impede the voluntary motion [13], [35].”
BackgroundMethodSelf-citationXu, Y., & Hollerbach, J. M. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.752938 · Cited by 43 · cited 2×
“The dynamics of a multiDOF arm joint can be modeled as [23], [24]”
BackgroundMethodEvaluation of a wearable orthosis and an associated algorithm for tremor suppression
Manto, M. U., Rocón, E., Pons, J. L., Lois, J. M. B., & Camut, S. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/4/007 · Cited by 42 · cited 2×
“to the characteristics of the patient’s tremor [10], [19].”
BackgroundControllable mechanical tremor reduction. Assessment of two orthoses
Lois, J. M. B., Martinez-Reyero, A. I., Castillo, A., Rocón, E., Pons, J. L., Loureiro, R. C. V., Manto, M. U., Normie, L., & Soede, M. (2007) · Technology and Disability · doi:10.3233/tad-2007-19402 · Cited by 34 · cited 2×
“, a magnetorheological damper (MRD) [11]–[13], or a passive damper [12], [14], [15].”
BackgroundAdaptive band-pass filter (ABPF) for tremor extraction from inertial sensor data
Popović, L. Z., Šekara, T. B., & Popović, M. B. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2010.03.018 · Cited by 29
Impedance characteristics of a neuromusculoskeletal model of the human arm II. Movement control
Stroeve, S. (1999) · Biological Cybernetics · doi:10.1007/s004220050578 · Cited by 20 · cited 2×
“this cannot happen, since the joint stiffness and damping are positively correlated [40]–[42].”
BackgroundActive tremor estimation and suppression in human elbow joint
Taheri, B., Case, D., & Richer, E. (2011) · ASME 2011 Dynamic Systems and Control Conference and Bath/ASME Symposium on Fluid Power and Motion Control, Volume 2 · doi:10.1115/dscc2011-6185 · Cited by 18 · cited 1×
“rejection algorithm to cancel the tremorous motion [20].”
BackgroundSelf-citation“Old” and emerging Therapies of Human Tremor
Grimaldi, G., & Manto, M. U. (2010) · Clinical Medicine Insights Therapeutics · doi:10.4137/cmt.s2999 · Cited by 18
Evaluation of pneumatic cylinder actuators for hand prostheses
Peerdeman, B., Smit, G., Stramigioli, S., Plettenburg, D. H., & Misra, S. (2012) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290807 · Cited by 14 · cited 1×
“The orthosis will be powered using high-pressure CO2 canisters [43] or by a pneumatic battery [44], [45].”
MethodPathological tremors: Deterministic chaos or nonlinear stochastic oscillators?
Timmer, J. (2000) · AIP conference proceedings · doi:10.1063/1.1302385 · Cited by 9
Robust Tremor Attenuation for Single DOF Model of Human Elbow Joint With Parametric Uncertainties
Taheri, B., Case, D., & Richer, E. (2011) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2011-64443 · Cited by 5 · cited 1×
“The numerical simulations showed that the stabilizer significantly attenuated any motion with frequency higher than 3 Hz, but introduced undesirable phase lag in the intentional motion [22].”
BackgroundSelf-citationTaheri, B., Case, D., & Richer, E. (2012) · ASME Dynamic Systems and Control Conference (DSCC) · doi:10.1115/dscc2012-movic2012-8707 · Cited by 4 · cited 1×
“The dynamics of a multiDOF arm joint can be modeled as [23], [24]”
BackgroundSelf-citation
Research works printed but not linked: 1
- khalil, 2002, Nonlinear Systems, 3
Cited by
Modular-Controller-Design-Based Fast Terminal Sliding Mode for Articulated Exoskeleton Systems
Madani, T., Daâchi, B., & Djouani, K. (2016) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2016.2579603 · Cited by 77
“In the literature, many techniques have been proposed to design robust controllers for nonlinear robotic systems in general [9]–[11] or for exoskeletons in particular [12], [13].”
BackgroundAn Integrated Intelligent Nonlinear Control Method for a Pneumatic Artificial Muscle
Ba, D. X., Truong, D. Q., & Ahn, K. K. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2558292 · Cited by 76
“In [23]–[25], the nonlinear models were derived more comprehensively than in [22] to exactly describe the system behavior.”
BackgroundMedical Devices for Tremor Suppression: Current Status and Future Directions
Mo, J., & Priefer, R. (2021) · Biosensors · doi:10.3390/bios11040099 · Cited by 77
Fromme, N. P., Camenzind, M., Riener, R., & Rossi, R. M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0543-7 · Cited by 70
A Review on Wearable Technologies for Tremor Suppression
Lora-Millan, J. S., Delgado-Oleas, G., Benito-León, J., & Rocon, E. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.700600 · Cited by 62
“(57) estimated and canceled the muscle torque responsible for tremor movements.”
Background
Metadata
- Authors
- Taheri, B., Case, D., & Richer, E.
- Affiliations
- Southern Methodist University (US)
- ORCID
- Richer, Edmond
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2015-04
- Volume
- 20
- Issue
- 2
- Pages
- 717-727
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2167260503
- Semantic Scholar
- 17a18b7601ad724b581ed4008ba56d1a1288ded6
- Cited by
- 53
- References
- 46
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 6 · 2023: 4 · 2022: 5 · 2021: 7 · 2020: 4 · 2019: 10 · 2018: 4 · 2017: 4 · 2016: 5 · 2015: 1
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE/ASME Transactions on Mechatronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- pathological tremor, tremor suppression, torque estimation, fundamental frequency estimation, adaptive control, pneumatic actuators, closed-loop stability, parameter uncertainty, magnetorheological damper, orthosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.