Adaptive Suppression of Severe Pathological Tremor by Torque Estimation Method
The DOI matches its Crossref record; 44 of the 46 references it cites were found in a registry or an index.
Abstract
Tremor is a rhythmical and involuntary oscillatory movement of a body part. In addition to social embarrassment, tremor can be debilitating for daily activities. Recently, wearable active exoskeletons emerged as a noninvasive tremor suppression alternative to medication or surgery. The challenge in musculoskeletal tremor suppression is identifying and attenuating the tremor motion without adding resistance to the patient's intentional motion. In this research, an adaptive tremor suppression algorithm was designed to estimate the tremor fundamental frequency and calculate the proper suppressive force to be applied by the orthosis to the patient's arm. Stability of the closed-loop system and robustness against the parametric uncertainties were analyzed. An experimental setup was designed and developed to emulate the dynamics of a human wrist with intentional and tremor motion. A pneumatic cylinder and a sliding mode integral controller was used to apply orthotic suppressive force. The algorithm was implemented with an NI cRIO real-time controller and tested using clinical data from ten patients with severe pathological tremor. Experimental results showed tracking of the tremor frequency with less than 3-s response time, and an average 34.5 dB (98.1%) and 11.8 dB (74.3%) reduction of tremor amplitude at the fundamental and second-harmonic frequencies, respectively. The average resistance force to the intentional motion was 0.7 N and the average position error was 2.08% (0.18 dB). The results were compared with passive tremor suppression using a tunable magnetorheological damper.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The remaining systems focused on design or experimental testing whereby the human motion (tremor and voluntary) was simulated physically or in software [4, 16, 22–26, 33–35].”
From Controlling a motorized orthosis to follow elbow volitional movement: tests with individuals with pathological tremor (2019) · cites this paper as [26]
In the citing paper
“A study by Taheri et al. reported the actuator resistive forces to the voluntary motions in a tremor simulation system [26].”
From Controlling a motorized orthosis to follow elbow volitional movement: tests with individuals with pathological tremor (2019) · cites this paper as [26]
In the citing paper
“ET and PD frequencies are considered to be in the range of 4–12 and 4–6 Hz, respectively, while ADL tend to be in the range of 0–2 Hz (Mann et al., 1989; Wyne, 2005; Taheri et al., 2015).”
From Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression (2016) · cites this paper as Taheri et al., 2015
In the citing paper
“Our studying of the first two tremor harmonics was based on a finding reported by Taheri et al. (2015) where it was shown that the first two harmonics contain the majority (above 94%) of the signal power.”
From Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression (2016) · cites this paper as Taheri et al. (2015)
In the citing paper
“The average position error on the voluntary movement was 2.08%.”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [57]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981
A High Performance Pneumatic Force Actuator System: Part I—Nonlinear Mathematical Model
Richer, E., & Hurmuzlu, Y. (2000) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.1286336 · Cited by 485
Self-citationTreatment of patients with essential tremor
Deuschl, G., Raethjen, J., Hellriegel, H., & Elble, R. (2011) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70322-7 · Cited by 428 · cited 1×
“of patients do not respond to the treatment or the positive effects are temporary [3]–[5].”
BackgroundGomi, H., & Osu, R. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-21-08965.1998 · Cited by 352 · cited 1×
“The scalar parameters κ and β are not constant as shown in numerous studies [25], [26].”
ResultDesign and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349 · cited 2×
“tremor suppression, as has been previously proposed [9], [10], [12], [19].”
BackgroundElble, R. J. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199603000-00004 · Cited by 271 · cited 1×
“It primarily influences hand motion, though it can affect the head, face, and trunk [29].”
BackgroundHuman arm stiffness characteristics during the maintenance of posture
Flash, T., & Mussa-Ivaldi, F. (1990) · Experimental Brain Research · doi:10.1007/bf00231251 · Cited by 257 · cited 2×
“this cannot happen, since the joint stiffness and damping are positively correlated [40]–[42].”
BackgroundThe pathophysiology of parkinsonian tremor: a review
Deuschl, G., Raethjen, J., Baron, R., Lindemann, M., Wilms, H., & Krack, P. (2000) · Journal of Neurology · doi:10.1007/pl00007781 · Cited by 251 · cited 1×
“of patients do not respond to the treatment or the positive effects are temporary [3]–[5].”
BackgroundClinical Neurophysiology of Tremor
Deuschl, G., Krack, P., Lauk, M., & Timmer, J. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199603000-00002 · Cited by 210 · cited 1×
“is mostly postural and kinetic tremor (action tremor) [1], [2].”
BackgroundTime-Domain Signal Analysis Using Adaptive Notch Filter
Mojiri, M., Karimi-Ghartemani, M., & Bakhshai, A. (2007) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2006.885686 · Cited by 180 · cited 1×
“where ξe1 , ξe2 , and ξe3 are the states of the estimator, ωT (t) is the estimated tremor fundamental frequency, and ζe and γ govern the speed of convergence and the performance of the frequency estimator [34].”
Background
Research works printed but not linked: 1
- khalil, 2002, Nonlinear Systems, 3
Cited by
Modular-Controller-Design-Based Fast Terminal Sliding Mode for Articulated Exoskeleton Systems
Madani, T., Daâchi, B., & Djouani, K. (2016) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2016.2579603 · Cited by 77
“In the literature, many techniques have been proposed to design robust controllers for nonlinear robotic systems in general [9]–[11] or for exoskeletons in particular [12], [13].”
BackgroundAn Integrated Intelligent Nonlinear Control Method for a Pneumatic Artificial Muscle
Ba, D. X., Truong, D. Q., & Ahn, K. K. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2558292 · Cited by 82
“In [23]–[25], the nonlinear models were derived more comprehensively than in [22] to exactly describe the system behavior.”
BackgroundMedical Devices for Tremor Suppression: Current Status and Future Directions
Mo, J., & Priefer, R. (2021) · Biosensors · doi:10.3390/bios11040099 · Cited by 78
Fromme, N. P., Camenzind, M., Riener, R., & Rossi, R. M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0543-7 · Cited by 62
A Review on Wearable Technologies for Tremor Suppression
Lora-Millan, J. S., Delgado-Oleas, G., Benito-León, J., & Rocon, E. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.700600 · Cited by 62
“(57) estimated and canceled the muscle torque responsible for tremor movements.”
BackgroundVoluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression
Herrnstadt, G., & Menon, C. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00029 · Cited by 49
“At its foundation, impedance control provides a frequencydependent relation between motion (i.e., of a limb) and a force (Pledgie et al., 2000; Hashemi et al., 2004; Rocon et al., 2007a; Taheri et al., 2015).”
BackgroundAtashzar, S. F., Shahbazi, M., Tavakoli, M., & Patel, R. V. (2017) · The International Journal of Robotics Research · doi:10.1177/0278364916689139 · Cited by 41
“This model includes (but is not limited to) the commonly-used passive linear massspring-damper models introduced in the literature for the dynamical reaction of a healthy human upper-limb Tsuji et al. (1995), Masia and Squeri (2014), Dyck and Tavakoli (2013) and post-stroke patients McCrea et al.”
BackgroundMethodTremor-Suppression Orthoses for the Upper Limb: Current Developments and Future Challenges
Nguyen, S. H., & Luu, T. P. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.622535 · Cited by 40
Shahtalebi, S., Atashzar, S. F., Samotus, O., Patel, R. V., Jog, M. S., & Mohammadi, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-58912-9 · Cited by 32
“PHT therapies such as oral medication, therapeutic lesions, Gamma-knife radiosurgery, and Deep Brain Stimulation (DBS) 18 focus on alleviating tremor severity and improving arm functionality 19–21 .”
BackgroundReal-Time Voluntary Motion Prediction and Parkinson’s Tremor Reduction Using Deep Neural Networks
Ibrahim, A. H., Zhou, Y., Jenkins, M. E., Trejos, A. L., & Naish, M. D. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3097007 · Cited by 34
Herrnstadt, G., McKeown, M. J., & Menon, C. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0484-1 · Cited by 30
Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.10.007 · Cited by 29
Admittance-Based Voluntary-Driven Motion With Speed-Controlled Tremor Rejection
Herrnstadt, G., & Menon, C. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2555811 · Cited by 29
“the tremor frequency [24], [26] and algorithms that model the tremor component, such as the WFLC, which fits a sine wave”
BackgroundMethodInfluentialBhidayasiri, R., Maytharakcheep, S., Phumphid, S., & Maetzler, W. (2022) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2022.120197 · Cited by 28
Tremor-Active Controller for Dielectric Elastomer-Based Pathological Tremor Suppression
Kelley, C. R., & Kauffman, J. L. (2020) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2020.2972884 · Cited by 26
“Previous research has considered three general control strategies for active tremor suppression: impedance control, tremor torque cancellation, and voluntary motion tracking [11], [13], [15]–[17].”
BackgroundA Layer Jamming Soft Glove for Hand Tremor Suppression
Wanasinghe, A. T., Awantha, W. V. I., Kavindya, A. G. P., Kulasekera, A. L., Chathuranga, D. S., & Senanayake, B. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3135497 · Cited by 24
Adaptive notch filter for pathological tremor suppression using permanent magnet linear motor
Zamanian, A. H., & Richer, E. (2019) · Mechatronics · doi:10.1016/j.mechatronics.2019.102273 · Cited by 22
Self-citationMechanical vibration does not systematically reduce the tremor in essential tremor patients
Lora-Millán, J. S., López-Blanco, R., Gallego, J. Á., Méndez-Guerrero, A., González de la Aleja, J., & Rocon, E. (2019) · Scientific Reports · doi:10.1038/s41598-019-52988-8 · Cited by 20
Towards wearable tremor suppression using dielectric elastomer stack actuators
Kelley, C. R., & Kauffman, J. L. (2020) · Smart Materials and Structures · doi:10.1088/1361-665x/abccdc · Cited by 22
HMFP-DBRNN: Real-Time Hand Motion Filtering and Prediction via Deep Bidirectional RNN
Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2894005 · Cited by 17
Tremor Estimation and Removal in Robot-Assisted Surgery Using Lie Groups and EKF
Rana, R., Gaur, P., Agarwal, V., & Parthasarathy, H. (2019) · Robotica · doi:10.1017/s0263574719000341 · Cited by 17
A robust time-delay nonlinear controller for a pneumatic artificial muscle
Ba, D. X., & Ahn, K. K. (2018) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-018-0003-5 · Cited by 16
Paik, P., Thudi, S., & Atashzar, S. F. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2022.3197932 · Cited by 17
Developing an Assisting Device to Reduce the Vibration on the Hands of Elders
Van, H. P., & Ngo, H. Q. T. (2021) · Applied Sciences · doi:10.3390/app11115026 · Cited by 16
“In detail, tremors affect about fifteen percent of the population from fifty to eighty-nine years old, causing patients difficulty in daily actions such as eating, dressing, and writing [12].”
BackgroundA Bimodal Detection-Based Tremor Suppression System for Vascular Interventional Surgery Robots
Li, X., Guo, S., Shi, P., Jin, X., Kawanishi, M., & Suzuki, K. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3216367 · Cited by 13
“According to [27], analysis results demonstrated two major frequency components with changeable frequency and amplitude, which contain most of the energy of the tremor signals (94.”
BackgroundStudy on Robust Control for the Vascular Interventional Surgical Robot
Guo, J. F., Yang, S., Guo, S., Meng, C., & Qi, L. (2019) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2019.8816363 · Cited by 13
“Because of the characteristics of the vascular interventional surgical robot, we will try our best to imitate the way doctors operate in the actual operation [11].”
BackgroundExploring dielectric elastomers as actuators for hand tremor suppression
Kelley, C. R., & Kauffman, J. L. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2258735 · Cited by 11
Tremor suppression controller for dielectric elastomer orthosis
Kelley, C. R., & Kauffman, J. L. (2018) · Electroactive Polymer Actuators, Sensors, and Devices (EAPAD) · doi:10.1117/12.2296697 · Cited by 7
“θ̇ bp = 1 4 T 2 s + 4ζbpωT Ts + ω2 T [ 4ζbpωT Ts θ̇ hp − 4ζbpωT Ts θ̇k−2 hp + ( 8 T 2 s − 2ω(2) T )θ̇k−1 bp + (− 4 T 2 s + 4ζbpωT Ts + ω(2) T )θ̇ k−2 bp ] (19)”
Study on physiological tremor recognition algorithm in the vascular interventional surgical robot
Guo, S., Shen, R., Xiao, N., Bao, X., Yang, C. W., & Cui, J. (2018) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2018.8484567 · Cited by 9
Elbow Orthosis for Tremor Suppression – A Torque Based Input Case
Herrnstadt, G., & Menon, C. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-56148-6_25 · Cited by 8
Necessary dielectric elastomer parameters for wearable tremor suppression
Kelley, C. R., & Kauffman, J. L. (2019) · Electroactive Polymer Actuators, Sensors, and Devices (EAPAD) · doi:10.1117/12.2514335 · Cited by 6
“Therefore, equations (5), (9), (11), and (12) define the dynamics of the system.”
BackgroundA Tremor-Suppressing Strategy Based on the Equivalent-Input-Disturbance Approach
Xie, M., She, J., Liu, Z., Yang, Z., & Sato, D. (2024) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2024.3375911 · Cited by 6
“Three main control strategies have been used to solve these problems: impedance control [14], voluntary motion tracking [15], and tremor-torque cancellation [16].”
MethodBhidayasiri, R., Prasertpan, T., & Tinazzi, M. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-99494-1.00020-4 · Cited by 6
Yousef, M., Hafizh, M., Sassi, S., & Muthalif, A. G. A. (2023) · Journal of Vibration and Control · doi:10.1177/10775463231158196 · Cited by 4
“The challenge for active tremor suppression at the musculoskeletal level is not to affect voluntary motion (Manto et al., 2007; Rocon et al., 2007; Taheri et al., 2015).”
BackgroundDevelopment of a Textile Integrated, Two-State Controlled Tremor Suppression Orthosis for the Wrist
Fromme, N. P., Esser, A., Camenzind, M., Mylius, V., Baumann, C. R., Büchele, F., Riener, R., Wolf, P., & Rossi, R. M. (2023) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2023.3293192 · Cited by 4
“04Nms/rad, and stiffness KH to 1Nm/rad, according to the literature [47], [56], [60], [61], [62].”
BackgroundInfluentialIntroduction to Adaptive and Robust Active Vibration Control
Landau, I. D., Airimitoaie, T.-B., Silva, A. C., & Constantinescu, A. (2016) · Advances in industrial control · doi:10.1007/978-3-319-41450-8_1 · Cited by 3
Desenvolvimento de Controlador de Movimento para Cilindro Pneumático de Baixo Atrito
Pinto, J. P. B. D. S. (2017) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/n8hn-ad89 · Cited by 3
A Non-Invasive, Soft Robotic Wearable Glove to Attenuate Hand Tremors
Youhanaie, K., & Hashem, R. (2022) · Journal of Student Research · doi:10.47611/jsrhs.v11i3.3814 · Cited by 2
A Real-Time Voluntary Motion Extraction Method Based on an Adaptive Filter
Xie, M., She, J., Liu, Z., & Yang, Z. (2023) · Journal of Advanced Computational Intelligence and Intelligent Informatics · doi:10.20965/jaciii.2023.p0372 · Cited by 2
A Novel Approach to Parkinson’s Tremor Suppression: E-BMFLC and LADRC Integration
Qi, P., Yang, J., Dai, Y., Zhang, H., & Tong, J. (2024) · IEEE Access · doi:10.1109/access.2024.3424395 · Cited by 3
“…mechanical coupling arrangement imparts significant mechanical efficiency losses to the WTSG. Zamanian and Richer have harnessed a combined approach integrating an adaptive frequency estimator (AFE) and active disturbance rejection (ADR) techniques to mitigate wrist tremors [21], [22], [23].”
BackgroundWang, K., Wu, M., Sun, Z., & Huang, Q. (2024) · Sensors · doi:10.3390/s24165405 · Cited by 2
“Subsequent developments in active orthotics have maintained similar design principles and mechatronic integration but have enhanced actuator designs to reduce weight and improve capabilities for tremor suppression [22,23].”
BackgroundTraining of Deep Bidirectional Rnns for Hand Motion Filtering Via Multimodal Data Fusion
Shahtalebi, S., Atashzar, S. F., Patel, R. V., & Mohammadi, A. (2019) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip45357.2019.8969080 · Cited by 2
“Thus, numerous research works in the literature [5–9] have been conducted to efficiently and accurately characterize, estimate, and separate the voluntary and involuntary components of motion, aiming at minimizing the estimation error and phase lag, while optimizing the computational efficacy for real-time implementat…”
The role of neurorehabilitation in the suppression of pathological tremor
Lora-Millán, J. S., & Rocón, E. (2025) · Elsevier eBooks · doi:10.1016/b978-0-12-819877-3.00011-1 · Cited by 1
Study on the Tremor Elimination Strategy for the Vascular Interventional Surgical Robot
Guo, J. F., Yang, S., & Guo, S. (2020) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma49215.2020.9233518 · Cited by 1
“For stress tremor, the most easily obtained features are velocity and acceleration [14].”
BackgroundMechatronic Devices for Upper Limb Tremor
Zhou, Y., Daemi, P., Edmonds, B. P. R., Habibollahi, Z., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2023) · Contemporary clinical neuroscience · doi:10.1007/978-3-031-26128-2_22 · Cited by 1
Oliver, S., & Atashzar, S. F. (2024) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2024.3382496 · Cited by 1
“The perturbation signal was a mixed-harmonic sine wave with frequencies ranging from one to five Hertz (covering the typical range of voluntary human interaction frequencies [31], [32]).”
BackgroundAnalytical modelling of a dynamic vibration absorber for Parkinson disease
Rincón, C., & Alencastre, J. (2023) · Common Library Network (Der Gemeinsame Bibliotheksverbund) · doi:10.22032/dbt.58878 · Cited by 1
Design of A Power-Assistive Robust Controller for Parkinson's Tremor in Human
Mugilarasi, P., & Sheela, M. (2015)
Voluntary Driven, Velocity Controlled Tremor Suppression
Herrnstadt, G. (2017) · Summit (Simon Fraser University)
Vieira, G. S., Silva, A. A., & de Santana, R. A. C. (2021) · Research Society and Development · doi:10.33448/rsd-v10i7.16346
Developing a Device- Independent Software for Adaptive Tremor Suppression Orthoses
Zhang, A. (2019) · IEEE MIT Undergraduate Research Technology Conference (URTC) · doi:10.1109/urtc49097.2019.9660564
Dispositivos tecnológicos para la supresión del temblor
Blanco, R. L. (2025) · Kranion · doi:10.24875/kranion.m22000023
Developing a wearable device for upper extremity tremors
Yıldız, S. D., Akgün, G., Günal, D. İ., Kaplanoğlu, E., Aküner, M. C., & Sehirli, U. S. (2024) · Marmara medical journal · doi:10.5472/marumj.1483038 · Cited by 1
Ghosh, R., Henry, C., Tauseef, M., & Sarkar, N. (2025) · Assistive Technology · doi:10.1080/10400435.2025.2580504
A Wearable Hand Tremor-Suppressing Glove Using PVC Gel-Based Actuators and Force Sensors
Liu, C., Wang, Y., & Zhang, K. (2026) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2026.3663307
“This approach is commonly used in preliminary dynamic analyses for tremor suppression devices [47], [48].”
Yıldız, S. D. (2023) · Dspace Repository (Marmara Üniversitesi)
Metadata
- Authors
- Taheri, B., Case, D., & Richer, E.
- Affiliations
- Southern Methodist University (US)
- ORCID
- Richer, Edmond
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2015-04
- Volume
- 20
- Issue
- 2
- Pages
- 717-727
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2167260503
- Semantic Scholar
- 17a18b7601ad724b581ed4008ba56d1a1288ded6
- Cited by
- 53
- References
- 46
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 6 · 2023: 4 · 2022: 5 · 2021: 7 · 2020: 4 · 2019: 10 · 2018: 4 · 2017: 4 · 2016: 5 · 2015: 1
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE/ASME Transactions on Mechatronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- pathological tremor, tremor suppression, torque estimation, fundamental frequency estimation, adaptive control, pneumatic actuators, closed-loop stability, parameter uncertainty, magnetorheological damper, orthosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.