Design and Development of a Mechatronic System for Noninvasive Refilling of Implantable Artificial Pancreas
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The aim of this study is to contribute to the advancement of the mechatronic implantable artificial organs field by demonstrating the feasibility of a mechatronic refilling module to be used with implantable artificial organs (and particularly suitable for an artificial pancreas), and permitting a completely noninvasive refilling procedure without the need for dedicated surgical interventions. We described a refilling module, chronically interfaced with the duodenum wall, based on a magnetic switchable device, and able to reversibly dock an ingestible insulin carrier, whenever required. The capsule was provided with sensors in order to reveal its approach. A punching system was also developed with the aim of assuring a safe transfer of the insulin from the capsule to an implanted reservoir. The key components of the system were developed and tested. Finally, they were integrated in a preliminary prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584 · cited 1×
“glucose and blood glucose can be markedly different [8], [9].”
BackgroundClosed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Model Predictive Control of Type 1 Diabetes: An in Silico Trial
Magni, L., Raimondo, D. M., Bossi, L., Dalla Man, C., De Nicolao, G., Kovatchev, B., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100603 · Cited by 317
Fully Integrated Artificial Pancreas in Type 1 Diabetes
Breton, M., Farret, A., Bruttomesso, D., Anderson, S., Magni, L., Patek, S., Dalla Man, C., Place, J., Demartini, S., Del Favero, S., et al. (2012) · Diabetes · doi:10.2337/db11-1445 · Cited by 315
Cited by
The grand challenges of Science Robotics
Yang, G.-Z., Bellingham, J., Dupont, P. E., Fischer, P., Floridi, L., Full, R., Jacobstein, N., Kumar, V., McNutt, M., Merrifield, R., et al. (2018) · Science Robotics · doi:10.1126/scirobotics.aar7650 · Cited by 1,177
Toffanin, C., Magni, L., & Cobelli, C. (2021) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2021.3075775 · Cited by 22
Modeling Intraperitoneal Insulin Absorption in Patients with Type 1 Diabetes
Schiavon, M., Cobelli, C., & Dalla Man, C. (2021) · Metabolites · doi:10.3390/metabo11090600 · Cited by 6
“Finally, future developments of the present work will also include testing the validity of the model to describe IP insulin absorption using other IP insulin administration systems, such as the DiaPort by Roche (Second Generation, Roche Diagnostics, Mannheim, Germany), as well as more recent devices [28].”
Method
Metadata
- Authors
- Iacovacci, V., Ricotti, L., Dario, P., & Menciassi, A.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2015-06
- Volume
- 20
- Issue
- 3
- Pages
- 1160-1169
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2116427719
- Cited by
- 42
- References
- 5
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Development of a Mechatronic System for Noninvasive Refilling of Implantable Artificial Pancreas. https://app.cochat.ai/papers/10.1109/tmech.2014.2327196
- The paper
- Iacovacci, V., Ricotti, L., Dario, P., & Menciassi, A. (2015). Design and Development of a Mechatronic System for Noninvasive Refilling of Implantable Artificial Pancreas. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2014.2327196
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.