A 5-D Localization Method for a Magnetically Manipulated Untethered Robot Using a 2-D Array of Hall-Effect Sensors
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
This paper introduces a new five-dimensional localization method for an untethered meso-scale magnetic robot, which is manipulated by a computer-controlled electromagnetic system. The developed magnetic localization setup is a two-dimensional array of mono-axial Hall-effect sensors, which measure the perpendicular magnetic fields at their given positions. We introduce two steps for localizing a magnetic robot more accurately. First, the dipole modeled magnetic field of the electromagnet is subtracted from the measured data in order to determine the robot's magnetic field. Secondly, the subtracted magnetic field is twice differentiated in the perpendicular direction of the array, so that the effect of the electromagnetic field in the localization process is minimized. Five variables regarding the position and orientation of the robot are determined by minimizing the error between the measured magnetic field and the modeled magnetic field in an optimization method. The resulting position error is 2.1±0.8 mm and angular error is 6.7±4.3° within the applicable range (5 cm) of magnetic field sensors at 200 Hz. The proposed localization method would be used for the position feedback control of untethered magnetic devices or robots for medical applications in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microrobots for Minimally Invasive Medicine
Nelson, B. J., Kaliakatsos, I. K., & Abbott, J. J. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-010510-103409 · Cited by 1,968
Hedrick, T. L. (2008) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/3/3/034001 · Cited by 1,360 · cited 1×
“using an image processing software [29].”
Biomedical Applications of Untethered Mobile Milli/Microrobots
Sitti, M., Ceylan, H., Hu, W., Giltinan, J., Turan, M., Yim, S., & Diller, E. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2385105 · Cited by 893 · cited 1×
“MAGNETICALLY actuated capsule endoscopes (MACEs) provide a promising medical technology for minimally invasive diagnosis on gastrointestinal organs [1]–[7].”
BackgroundSelf-citationDesign and Rolling Locomotion of a Magnetically Actuated Soft Capsule Endoscope
Yim, S., & Sitti, M. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2163861 · Cited by 400 · cited 1×
“we proposed a new multifunctional endoscopic capsule robot and an original magnetic manipulation method [10]–[13].”
MethodSelf-citationCiuti, G., Valdastri, P., Menciassi, A., & Dario, P. (2010) · Robotica · doi:10.1017/s0263574709990361 · Cited by 306
Yim, S., Gultepe, E., Gracias, D. H., & Sitti, M. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2283369 · Cited by 292
Self-citationA Review of Localization Systems for Robotic Endoscopic Capsules
Than, T. D., Alıcı, G., Zhou, H., & Li, W. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2201715 · Cited by 291
Fabrication of magnetic actuator for use in a capsule endoscope
SENDOH, M., Ishiyama, K., & Arai, K. I. (2003) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2003.816731 · Cited by 242
Yan, Z., Li, Y., Zhang, C., & Yang, Q. (2014) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2291861 · Cited by 226
Optimal Permanent-Magnet Geometries for Dipole Field Approximation
Petruska, A. J., & Abbott, J. J. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2205014 · Cited by 204 · cited 1×
“In (5), those two dipole terms scale with ‖re‖ as described in (2), and the quadrupole and hexapole terms scale with ‖re‖ and ‖re‖ , respectively [26].”
Background
Cited by
Biomedical Applications of Untethered Mobile Milli/Microrobots
Sitti, M., Ceylan, H., Hu, W., Giltinan, J., Turan, M., Yim, S., & Diller, E. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2385105 · Cited by 893
Self-citationChallenges of continuum robots in clinical context: a review
da Veiga, T., Chandler, J. H., Lloyd, P., Pittiglio, G., Wilkinson, N. J., Hoshiar, A. K., Harris, R. A., & Valdastri, P. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab9f41 · Cited by 280
Ozyoruk, K. B., Gokceler, G. I., Bobrow, T. L., Coskun, G., Incetan, K., Almalioglu, Y., Mahmood, F., Curto, E., Perdigoto, L., Oliveira, M., et al. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102058 · Cited by 270
Control and Autonomy of Microrobots: Recent Progress and Perspective
Jiang, J., Yang, Z., Ferreira, A., & Zhang, L. (2022) · Advanced Intelligent Systems · doi:10.1002/aisy.202100279 · Cited by 173
Magnetically Actuated Continuum Medical Robots: A Review
Yang, Z., Yang, H., Cao, Y., Cui, Y., & Zhang, L. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200416 · Cited by 165
Robotic wireless capsule endoscopy: recent advances and upcoming technologies
Cao, Q., Deng, R., Pan, Y., Liu, R., Chen, Y., Gong, G., Zou, J., Yang, H., & Han, D. (2024) · Nature Communications · doi:10.1038/s41467-024-49019-0 · Cited by 165
“Recent studies 59 – 61 indicate that by arranging a two-dimensional or three-dimensional (3D) array of hall-effect sensors around the capsule endoscope, positioning error can be reduced to a minimum of 1 mm, with anangular error of 5.1°.”
Influential
Metadata
- Authors
- Son, D., Yim, S., & Sitti, M.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2016-04
- Volume
- 21
- Issue
- 2
- Pages
- 708-716
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2292347270
- Cited by
- 172
- References
- 18
- FWCI
- 5.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.