The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Estimating distributed anatomical connectivity using fast marching methods and diffusion tensor imaging
Abstract
A method is presented for determining paths of anatomical connection between regions of the brain using magnetic resonance diffusion tensor information. Level set theory, applied using fast marching methods, is used to generate three-dimensional time of arrival maps, from which connection paths between brain regions may be identified. The method is demonstrated in the normal brain and it is shown that major white matter tracts may be elucidated and that multiple connections and tract branching are allowed. Maps of connectivity between brain regions are also determined. Four options are described for estimating the degree of connectivity between regions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Co-Planar Stereotaxic Atlas of the Human Brain
Talairach, J., & Tournoux, P. (1988) · Medical Entomology and Zoology · Cited by 11,798
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Co-planar stereotaxic atlas of the human brain
Laitinen, L. (1989) · Clinical Neurology and Neurosurgery · doi:10.1016/0303-8467(89)90128-5 · Cited by 7,565
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Estimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650
Level Set Methods and Fast Marching Methods
Sethian, J. A. (1999) · Medical Entomology and Zoology · Cited by 3,616
A fast marching level set method for monotonically advancing fronts.
Sethian, J. A. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.4.1591 · Cited by 3,221
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Tracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Computing geodesic paths on manifolds
Kimmel, R., & Sethian, J. A. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.15.8431 · Cited by 1,049
Analysis of partial volume effects in diffusion‐tensor MRI
Alexander, A. L., Hasan, K. M., Lazar, M., Tsuruda, J. S., & Parker, D. L. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1105 · Cited by 695
Global Minimum for Active Contour Models: A Minimal Path Approach
Cohen, L. D., & Kimmel, R. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007922224810 · Cited by 625
Interactive Segmentation with Intelligent Scissors
Mortensen, E. N., & Barrett, W. A. (1998) · Graphical Models and Image Processing · doi:10.1006/gmip.1998.0480 · Cited by 546
Detection and modeling of non‐Gaussian apparent diffusion coefficient profiles in human brain data
Alexander, D. C., Barker, G. J., & Arridge, S. R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10209 · Cited by 528
Self-citationCharacterization of anisotropy in high angular resolution diffusion‐weighted MRI
Frank, L. R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10156 · Cited by 510
Diffusion Tensor Imaging and Axonal Tracking in the Human Brainstem
Stieltjes, B., Kaufmann, W. E., van Zijl, P. C. M., Fredericksen, K., Pearlson, G. D., Solaiyappan, M., & Mori, S. (2001) · NeuroImage · doi:10.1006/nimg.2001.0861 · Cited by 492
User-Steered Image Segmentation Paradigms: Live Wire and Live Lane
Falcão, A. X., Udupa, J. K., Samarasekera, S., Sharma, S., Hirsch, B. E., & Lotufo, R. D. A. (1998) · Graphical Models and Image Processing · doi:10.1006/gmip.1998.0475 · Cited by 481
Regularization of Diffusion-Based Direction Maps for the Tracking of Brain White Matter Fascicles
Poupon, C., Clark, C. A., Frouin, V., Régis, J., Bloch, I., Le Bihan, D., & Mangin, J.-F. (2000) · NeuroImage · doi:10.1006/nimg.2000.0607 · Cited by 429
Diffusion tensor imaging can detect and quantify corticospinal tract degeneration after stroke
Werring, D. J. (2000) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.69.2.269 · Cited by 399
Rademacher, J. (2001) · Brain · doi:10.1093/brain/124.11.2232 · Cited by 235
Parker, G. J. M., Stephan, K. E., Barker, G. J., Rowe, J. B., MacManus, D. G., Wheeler-Kingshott, C. A. M., Ciccarelli, O., Passingham, R. E., Spinks, R. L., Lemon, R. N., et al. (2002) · NeuroImage · doi:10.1006/nimg.2001.0994 · Cited by 183
Self-citationBürgel, U., Schormann, T., Schleicher, A., & Zilles, K. (1999) · NeuroImage · doi:10.1006/nimg.1999.0497 · Cited by 140
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.3.co;2-h · Cited by 120
An O(N log N) algorithm for shape modeling.
Malladi, R., & Sethian, J. A. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.18.9389 · Cited by 84
Miklossy, J., & der Loos, H. V. (1991) · Journal of Neuropathology & Experimental Neurology · doi:10.1097/00005072-199101000-00001 · Cited by 78
Study of Connectivity in the Brain Using the Full Diffusion Tensor from MRI
Batchelor, P. G., Hill, D., Atkinson, D., & Calamante, F. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45729-1_10 · Cited by 47
Pujol, J., Martí-Vilalta, J. L., Junqué, C., Vendrell, P., Fernández, J., & Capdevila, A. (1990) · Stroke · doi:10.1161/01.str.21.3.404 · Cited by 45
Estimation of anatomical connectivity from diffusion tensor data
Koch, M., Glauche, V., Finsterbusch, J., Nolte, U., Frahm, J., & Büchel, C. (2001) · NeuroImage · doi:10.1016/s1053-8119(01)91519-8 · Cited by 21
Jones (1999) · doi:10.1002/(sici)1522-2594(199907)42:1<37::aid-mrm7>3.0.co;2-o
Basser (2000) · doi:10.1002/1522-2594(200010)44:4<625::aid-mrm17>3.0.co;2-o
(1999) · doi:10.1002/1531-8249(199902)45:2<265::aid-ana21>3.0.co;2-3
Cited by
Tournier, J.-D., Calamante, F., & Connelly, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.016 · Cited by 2,188
MRtrix: Diffusion tractography in crossing fiber regions
Tournier, J., Calamante, F., & Connelly, A. (2012) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22005 · Cited by 1,370
Smith, R. E., Tournier, J.-D., Calamante, F., & Connelly, A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.005 · Cited by 1,216
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Tractography: Where Do We Go from Here?
Jbabdi, S., & Johansen-Berg, H. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0033 · Cited by 614
Metadata
- Authors
- Parker, G. J. M., Wheeler-Kingshott, C. A. M., & Barker, G. J.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2002-05
- Volume
- 21
- Issue
- 5
- Pages
- 505-512
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2140529698
- Cited by
- 303
- References
- 32
- FWCI
- 11.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.