The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
A review of cardiac image registration methods
Abstract
In this paper, the current status of cardiac image registration methods is reviewed. The combination of information from multiple cardiac image modalities, such as magnetic resonance imaging, computed tomography, positron emission tomography, single-photon emission computed tomography, and ultrasound, is of increasing interest in the medical community for physiologic understanding and diagnostic purposes. Registration of cardiac images is a more complex problem than brain image registration because the heart is a nonrigid moving organ inside a moving body. Moreover, as compared to the registration of brain images, the heart exhibits much fewer accurate anatomical landmarks. In a clinical context, physicians often mentally integrate image information from different modalities. Automatic registration, based on computer programs, might, however, offer better accuracy and repeatability and save time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
A Simplex Method for Function Minimization
Nelder, J. A., & Mead, R. (1965) · The Computer Journal · doi:10.1093/comjnl/7.4.308 · Cited by 28,905
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
A survey of image registration techniques
Brown, L. G. (1992) · ACM Computing Surveys · doi:10.1145/146370.146374 · Cited by 4,057
Least-Squares Fitting of Two 3-D Point Sets
Arun, K. S., Huang, T. S., & Blostein, S. D. (1987) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1987.4767965 · Cited by 3,952
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Numerical recipes: the art of scientific computing
Press, W. H., Flannery, B. P., Teukolsky, S. A., Vetterling, W. T., & Chipperfield, J. R. (1987) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82860-3 · Cited by 3,304
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Multi-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,959
Deformable models in medical image analysis: a survey
McInerney, T., & Terzopoulos, D. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(96)80007-7 · Cited by 1,913
Rapid Automated Algorithm for Aligning and Reslicing PET Images
Woods, R. P., Cherry, S. R., & Mazziotta, J. C. (1992) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199207000-00024 · Cited by 1,912
Distance transformations in digital images
Borgefors, G. (1986) · Computer Vision, Graphics, and Image Processing · doi:10.1016/s0734-189x(86)80047-0 · Cited by 1,898
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
Accurate Three-Dimensional Registration of CT, PET, and/or MR Images of the Brain
Pelizzari, C. A., Chen, G. T. Y., Spelbring, D. R., Weichselbaum, R. R., & Chen, C.-T. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198901000-00004 · Cited by 1,096
Using Canny's criteria to derive a recursively implemented optimal edge detector
Deriche, R. (1987) · International Journal of Computer Vision · doi:10.1007/bf00123164 · Cited by 1,089
Alignment by maximization of mutual information
Viola, P., & Wells, W. M. (2002) · Proceedings of IEEE International Conference on Computer Vision · doi:10.1109/iccv.1995.466930 · Cited by 1,082
Hierarchical chamfer matching: a parametric edge matching algorithm
Borgefors, G. (1988) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.9107 · Cited by 1,056
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Medical image matching-a review with classification
van den Elsen, P. A., Pol, E.-J. D., & Viergever, M. A. (1993) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.195938 · Cited by 718
(2001) · Radiology · doi:10.1148/radiology.220.2.r01au28372 · Cited by 716
Alignment by Maximization of Mutual Information
Viola, P. A. (1995) · doi:10.21236/ada299525 · Cited by 614
Three-dimensional modeling for functional analysis of cardiac images, a review
Frangi, A. F., Niessen, W. J., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906421 · Cited by 533
A survey of hierarchical non-linear medical image registration
Lester, H., & Arridge, S. R. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00095-8 · Cited by 484
An algorithmic overview of surface registration techniques for medical imaging
Audette, M. A., Ferrie, F. P., & Peters, T. M. (2000) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00014-1 · Cited by 406
Hajnal, J. V., & Hill, D. (2001) · Lecture notes in computer science · doi:10.1007/978-3-032-25169-5 · Cited by 402
Handbook of Medical Imaging. Processing and Analysis
Bankman, I. N., & Morcovescu, S. (2002) · Medical Physics · doi:10.1118/1.1429630 · Cited by 396
Image Interpolation and Resampling
Thévenaz, P., Blu, T., & Unser, M. (2000) · Handbook of Medical Imaging · doi:10.1016/b978-012077790-7/50030-8 · Cited by 387
PET-CT image co-registration in the thorax: influence of respiration
Goerres, G. W., Kamel, E., Heidelberg, T.-N. H., Schwitter, M. R., Burger, C., & von Schulthess, G. K. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-001-0710-4 · Cited by 332
The principal axes transformation--a method for image registration.
Alpert, N. M., Bradshaw, J., Kennedy, D. N., & Correia, J. A. (1990) · PubMed · Cited by 282
Comparison and evaluation of retrospective intermodality image registration techniques:
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, Jr., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., et al. (1996) · SPIE Proceedings · doi:10.1117/12.237936 · Cited by 269
Multi-modality image registration by maximization of mutual information
Maes, F., Vandermeulen, D., & Suetens, P. L. (2000) · Cited by 255
Retrospective geometric correlation of MR, CT, and PET images.
Levin, D. N., Pelizzari, C. A., Chen, G. T., Chen, C. T., & Cooper, M. D. (1988) · Radiology · doi:10.1148/radiology.169.3.3263666 · Cited by 200
An Iterative Method for Finding Stationary Values of a Function of Several Variables
Powell, M. J. D. (1962) · The Computer Journal · doi:10.1093/comjnl/5.2.147 · Cited by 193
A review of medical image registration
Ma, B. (1999) · Information of Medical Equipment · Cited by 173
(2019) · Atlas of Ultrasound-Guided Regional Anesthesia · doi:10.1016/b978-0-323-50951-0.00015-3 · Cited by 172
Rogers, W. J., Shapiro, E. P., Weiss, J. L., Buchalter, M. B., Rademakers, F. E., Weisfeldt, M. L., & Zerhouni, E. A. (1991) · Circulation · doi:10.1161/01.cir.84.2.721 · Cited by 168
Fast Non-Rigid Matching of 3D Medical Images
Thirion, J. (1995) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 150
Fleming, J. S., & Allen, R. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00087-x · Cited by 147
An instrumented phantom system for analog computation of treatment plans.
Alderson, S. W., Lanzl, L. H., ROLLINS, M., & SPIRA, J. (1962) · PubMed · Cited by 145
Semiautomatic 3-D image registration as applied to interventional MRI liver cancer treatment
Carrillo, A., Duerk, J. L., Lewin, J. S., & Wilson, D. L. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845176 · Cited by 128
Pretorius, P. H., Xia, W., King, M. A., Tsui, B. M. W., Pan, T. S., & Villegas, B. J. (1997) · PubMed · Cited by 102
Declerck, J. M., Feldmar, J., Goris, M. L., & Betting, F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650870 · Cited by 102
A rapid and accurate method to realign PET scans utilizing image edge information.
Anderson, J. L. (1995) · PubMed · Cited by 100
Downey, D. B., & Fenster, A. (1998) · Ultrasound Quarterly · doi:10.1097/00013644-199803000-00003 · Cited by 90
Landmark-Based Registration Using Features Identified Through Differential Geometry
Pennec, X., Ayache, N., & Thirion, J. (2000) · Elsevier eBooks · doi:10.1016/b978-012077790-7/50037-0 · Cited by 89
The SMART scanner: a combined PET/CT tomograph for clinical oncology
Townsend, D. W., Beyer, T., Kinahan, P. E., Brun, T., Roddy, R., Nutt, R., & Byars, L. G. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1998.774368 · Cited by 84
Automated interstudy image registration technique for SPECT and PET.
Eberl, S., Kanno, I., Fulton, R., et al. (1996) · PubMed · Cited by 81
Cai, J., Chu, J. C. H., Recine, D. C., Sharma, M., Nguyen, C., Rodebaugh, R., Saxena, V. A., & Ali, A. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(98)00399-x · Cited by 76
Four-dimensional processing of deformable cardiac PET data
Klein, G. J., & Huesman, R. H. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00050-0 · Cited by 75
Automated registration of dynamic MR images for the quantification of myocardial perfusion
Bidaut, L. M., & Vallée, J. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1092 · Cited by 74
Automated iterative three-dimensional registration of positron emission tomography images.
Hoh, C. K., Dahlbom, M. L., Harris, G., Choi, Y. H., Hawkins, R. A., Phelps, M. E., & Maddahi, J. (1993) · PubMed · Cited by 72
Spatial and temporal registration of cardiac SPECT and MR images: methods and evaluation.
Faber, T. L., McColl, R. W., Opperman, R., Corbett, J. R., & Peshock, R. M. (1991) · Radiology · doi:10.1148/radiology.179.3.2028006 · Cited by 66
Accurate attenuation correction despite movement during PET imaging.
Andersson, J., Vagnhammar, B. E., & Schneider, H. (1995) · PubMed · Cited by 59
Bettinardi, V., Gilardi, M. C., Lucignani, G., Landoni, C., Rizzo, G., Striano, G., & Fazio, F. (1993) · PubMed · Cited by 34
Elastic Matching Using a Deformation Sphere
Lötjönen, J. M. P., & Mäkelä, T. O. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_65 · Cited by 33
Validation of Registration Accuracy
Woods, R. P. (2000) · Elsevier eBooks · doi:10.1016/b978-012077790-7/50036-9 · Cited by 29
Cited by
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“cardiac and respiratory motion) the key element in diagnosis becomes their spatio-temporal behavior [1, 2].”
BackgroundGo-ICP: A Globally Optimal Solution to 3D ICP Point-Set Registration
Yang, J., Li, H., Campbell, D., & Jia, Y. (2016) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2015.2513405 · Cited by 1,170
Medical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
Non-rigid image registration: theory and practice
Crum, W. R., Hartkens, T., & Hill, D. L. G. (2004) · The British Journal of Radiology · doi:10.1259/bjr/25329214 · Cited by 719
Review of brain MRI image segmentation methods
Balafar, M. A., Ramli, A. R., Saripan, M. I., & Mashohor, S. (2010) · Artificial Intelligence Review · doi:10.1007/s10462-010-9155-0 · Cited by 438
Metadata
- Authors
- Makela, T., Clarysse, P., Sipila, O., Pauna, N., Pham, Q. C., Katila, T., & Magnin, I. E.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2002-09
- Volume
- 21
- Issue
- 9
- Pages
- 1011-1021
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2145360090
- Cited by
- 361
- References
- 60
- FWCI
- 15.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.