The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities
Open accessAbstract
In magnetic resonance imaging, magnetic field inhomogeneities cause distortions in images that are reconstructed by conventional fast Fourier trasform (FFT) methods. Several noniterative image reconstruction methods are used currently to compensate for field inhomogeneities, but these methods assume that the field map that characterizes the off-resonance frequencies is spatially smooth. Recently, iterative methods have been proposed that can circumvent this assumption and provide improved compensation for off-resonance effects. However, straightforward implementations of such iterative methods suffer from inconveniently long computation times. This paper describes a tool for accelerating iterative reconstruction of field-corrected MR images: a novel time-segmented approximation to the MR signal equation. We use a min-max formulation to derive the temporal interpolator. Speedups of around 60 were achieved by combining this temporal interpolator with a nonuniform fast Fourier transform with normalized root mean squared approximation errors of 0.07%. The proposed method provides fast, accurate, field-corrected image reconstruction even when the field map is not smooth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huber, P. J. (1981) · Wiley Series in Probability and Statistics · doi:10.1002/0471725250 · Cited by 7,066
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Wiley Series in Probability and Statistics
(2008) · Wiley series in probability and statistics · doi:10.1002/series1345 · Cited by 4,217
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Nonuniform fast fourier transforms using min-max interpolation
Fessler, J. A., & Sutton, B. P. (2003) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2002.807005 · Cited by 1,337
Self-citationAdvances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Jackson, J. I., Meyer, C. H., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97598 · Cited by 1,059
Fast Fourier Transforms for Nonequispaced Data
Dutt, A., & Rokhlin, V. (1993) · SIAM Journal on Scientific Computing · doi:10.1137/0914081 · Cited by 918
Concomitant gradient terms in phase contrast MR: Analysis and correction
Bernstein, M. A., Zhou, X. J., Polzin, J. A., King, K. F., Ganin, A., Pelc, N. J., & Glover, G. H. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390218 · Cited by 547
Fessler, J. A., & Rogers, W. L. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.535846 · Cited by 518
Self-citationSampling density compensation in MRI: Rationale and an iterative numerical solution
Pipe, J. G., & Menon, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199901)41:1<179::aid-mrm25>3.0.co;2-v · Cited by 350
On the Fast Fourier Transform of Functions with Singularities
Beylkin, G. (1995) · Applied and Computational Harmonic Analysis · doi:10.1006/acha.1995.1026 · Cited by 334
A homogeneity correction method for magnetic resonance imaging with time-varying gradients
Noll, D. C., Meyer, C. H., Pauly, J. M., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.108599 · Cited by 277
Self-citationConjugate-gradient preconditioning methods for shift-variant PET image reconstruction
Fessler, J. A., & Booth, S. D. (1999) · IEEE Transactions on Image Processing · doi:10.1109/83.760336 · Cited by 236
Self-citationDeblurring for non‐2D fourier transform magnetic resonance imaging
Noll, D. C., Pauly, J. M., Meyer, C. H., Nishimura, D. G., & Macovskj, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250210 · Cited by 222
Self-citationSchneider, E., & Glover, G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180208 · Cited by 221
Inhomogeneity correction using an estimated linear field map
Irarrazabal, P., Meyer, C. H., Nishimura, D. G., & Macovski, A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350221 · Cited by 170
On the optimality of the gridding reconstruction algorithm
Sedarat, H., & Nishimura, D. G. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.848182 · Cited by 99
Concomitant gradient field effects in spiral scans
King, K. F., Ganin, A., Zhou, X. J., & Bernstein, M. A. (1999) · Magnetic Resonance in Medicine · Cited by 96
Rik Van De Walle, B., Barrett, H. H., Myers, K. J., Aitbach, M. I., Desplanques, B., Gmitro, A. F., Cornelis, J. P., & Lemahieu, I. A. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.897806 · Cited by 92
Off-resonance correction of MR images
Schomberg, H. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.781014 · Cited by 85
Numerical analysis of the non-uniform sampling problem
Strohmer, T. (2000) · Journal of Computational and Applied Mathematics · doi:10.1016/s0377-0427(00)00361-7 · Cited by 81
3 Principles of Magnetic Resonance Imaging
Tanttu, J. I., & SEPPONEN, R. E. (1996) · Cited by 79
Kadah, Y. M., & Hu, X. P. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380416 · Cited by 77
Image restoration from non-uniform magnetic field influence for direct Fourier NMR imaging
Sekihara, K., Kuroda, M., & Kohno, H. (1984) · Physics in Medicine and Biology · doi:10.1088/0031-9155/29/1/002 · Cited by 76
An inverse problem approach to the correction of distortion in EPI images
Munger, P., Crelier, G. R., Peters, T. M., & Pike, G. B. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.875186 · Cited by 75
Spiral Sampling in Magnetic Resonance Imaging-The Effect of Inhomogeneities
Yudilevich, E., & Stark, H. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307852 · Cited by 73
Algebraic reconstruction for magnetic resonance imaging under B/sub 0/ inhomogeneity
Kadah, Y. M., & Hu, X. P. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712126 · Cited by 49
Correction of MR k-space data corrupted by spike noise
Kao, Y., & MacFall, J. R. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.875184 · Cited by 30
Rapid MR image acquisition in the presence of background gradients
Noll, D. C. (2003) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2002.1029360 · Cited by 22
Self-citation
Cited by
SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
Lustig, M., & Pauly, J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22428 · Cited by 822
Accelerating SENSE using compressed sensing
Liang, D., Liu, B., Wang, J., & Ying, L. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22161 · Cited by 474
Using NFFT 3---A Software Library for Various Nonequispaced Fast Fourier Transforms
Keiner, J., Kunis, S., & Potts, D. (2009) · ACM Transactions on Mathematical Software · doi:10.1145/1555386.1555388 · Cited by 367
Model-Based Image Reconstruction for MRI
Fessler, J. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936726 · Cited by 335
Self-citationAccelerating advanced MRI reconstructions on GPUs
Stone, S. S., Haldar, J. P., Tsao, S. C., Hwu, W.-M. W., Sutton, B. P., & Liang, Z.-P. (2008) · Journal of Parallel and Distributed Computing · doi:10.1016/j.jpdc.2008.05.013 · Cited by 249
Self-citation
Metadata
- Authors
- Sutton, B. P., Noll, D. C., & Fessler, J. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2003-02
- Volume
- 22
- Issue
- 2
- Pages
- 178-188
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2135718700
- Cited by
- 397
- References
- 30
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.