We have implemented and validated an algorithm for three-dimensional positron emission tomography transmission-to-computed tomography registration in the chest, using mutual information as a similarity criterion. Inherent differences in the two imaging protocols produce significant nonrigid motion between the two acquisitions. A rigid body deformation combined with localized cubic B-splines is used to capture this motion. The deformation is defined on a regular grid and is parameterized by potentially several thousand coefficients. Together with a spline-based continuous representation of images and Parzen histogram estimates, our deformation model allows closed-form expressions for the criterion and its gradient. A limited-memory quasi-Newton optimization algorithm is used in a hierarchical multiresolution framework to automatically align the images. To characterize the performance of the method, 27 scans from patients involved in routine lung cancer staging were used in a validation study. The registrations were assessed visually by two expert observers in specific anatomic locations using a split window validation technique. The visually reported errors are in the 0- to 6-mm range and the average computation time is 100 min on a moderate-performance workstation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
A survey of image registration techniques
Brown, L. G. (1992) · ACM Computing Surveys · doi:10.1145/146370.146374 · Cited by 4,057
Algorithm 778: L-BFGS-B: Fortran subroutines for large-scale bound-constrained optimization
Zhu, C., Byrd, R. H., Lu, P., & Nocedal, J. (1997) · ACM Transactions on Mathematical Software · doi:10.1145/279232.279236 · Cited by 3,462
Alignment by Maximization of Mutual Information
Viola, P., & Wells III, W. M. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007958904918 · Cited by 2,610
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
Automated Image Registration: II. Intersubject Validation of Linear and Nonlinear Models
Woods, R. P., Grafton, S. T., Watson, J. D. G., Sicotte, N. L., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00028 · Cited by 994
B-spline signal processing. I. Theory
Unser, M., Aldroubi, A., & Eden, M. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193220 · Cited by 940
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Optimization of mutual information for multiresolution image registration
Unser, M., & Thevenaz, P. (2000) · IEEE Transactions on Image Processing · doi:10.1109/83.887976 · Cited by 697
Image registration by maximization of combined mutual information and gradient information
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.876307 · Cited by 670
B-spline signal processing. II. Efficiency design and applications
Unser, M., Aldroubi, A., & Eden, M. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193221 · Cited by 641
B-SPLINE SIGNAL PROCESSING: PART I-THEORY
Unser, M. A., Aldroubi, A., & Eden, M. (1993) · Cited by 626
Alignment by Maximization of Mutual Information
Viola, P. A. (1995) · doi:10.21236/ada299525 · Cited by 614
Fast B-spline transforms for continuous image representation and interpolation
Unser, M. A., Aldroubi, A., & Eden, M. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.75515 · Cited by 528
A survey of hierarchical non-linear medical image registration
Lester, H., & Arridge, S. R. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00095-8 · Cited by 484
B-SPLINE SIGNAL PROCESSING: PART II-EFFICIENT DESIGN AND APPLICATIONS
Unser, M. A., Aldroubi, A., & Eden, M. (1993) · Cited by 463
Matching 3-D anatomical surfaces with non-rigid deformations using octree-splines
Szeliski, R., & Lavall�e, S. (1996) · International Journal of Computer Vision · doi:10.1007/bf00055001 · Cited by 296
Voxel similarity measures for 3-D serial MR brain image registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., Rohlfing, T., Goodey, J., & Hawkes, D. J. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836369 · Cited by 277
Comparison and evaluation of retrospective intermodality image registration techniques:
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, Jr., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., et al. (1996) · SPIE Proceedings · doi:10.1117/12.237936 · Cited by 269
Multi-modality image registration by maximization of mutual information
Maes, F., Vandermeulen, D., & Suetens, P. L. (2000) · Cited by 255
Voxel Similarity Measures for 3D Serial MR Brain Image Registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., & Hawkes, D. J. (1999) · Lecture Notes in Computer Science · doi:10.1007/3-540-48714-x_48 · Cited by 246
The Theory and Practice of 3D PET
(1998) · Springer eBooks · doi:10.1007/978-94-017-3475-2 · Cited by 223
Recursive regularization filters: design, properties, and applications
Unser, M., Aldroubi, A., & Eden, M. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.75514 · Cited by 193
Unwarping of unidirectionally distorted EPI images
Kybic, J., Thevenaz, P., Nirkko, A., & Unser, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836368 · Cited by 187
Visual assessment of the accuracy of retrospective registration of MR and CT images of the brain
Fitzpatrick, J. M., Hill, D., Shyr, Y., West, J. B., Studholme, C., & Maurer, C. R. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730402 · Cited by 140
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., KESSLER, R. M., & Maciunas, R. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.759119 · Cited by 133
A pyramid approach to sub-pixel image fusion based on mutual information
Thévenaz, P., & Unser, M. A. (2002) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.1996.559484 · Cited by 89
Smith, D. K. (2001) · Journal of the Operational Research Society · doi:10.1057/palgrave.jors.2601183 · Cited by 71
Multimodal Image Registration by Maximization of the Correlation Ratio
Roche, A., Malandain, G., Ayache, N., & Pennec, X. (1998) · Cited by 65
A level-set based approach to image registration
Vemuri, B. C., Ye, J., Chen, Y., & Leonard, C. M. (2002) · IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA) · doi:10.1109/mmbia.2000.852364 · Cited by 58
van Herk, M., de Munck, J. C., Lebesque, J. V., Muller, S. H., Rasch, C. R. N., & Touw, A. (1998) · Medical Physics · doi:10.1118/1.598393 · Cited by 57
Spline Pyramids for Inter-Modal Image Registration Using Mutual Information
Thévenaz, P., & Unser, M. A. (1997) · Cited by 44
Spline pyramids for intermodal image registration using mutual information
Thévenaz, P., & Unser, M. A. (1997) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.292794 · Cited by 36
Cited by
3D Slicer as an image computing platform for the Quantitative Imaging Network
Fedorov, A., Beichel, R., Kalpathy-Cramer, J., Finet, J., Fillion-Robin, J.-C., Pujol, S., Bauer, C., Jennings, D., Fennessy, F., Sonka, M., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.05.001 · Cited by 9,023
A reproducible evaluation of ANTs similarity metric performance in brain image registration
Avants, B. B., Tustison, N. J., Song, G., Cook, P. A., Klein, A., & Gee, J. C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.025 · Cited by 4,796
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Comparison and evaluation of methods for liver segmentation from CT datasets
Heimann, T., van Ginneken, B., Styner, M. A., Arzhaeva, Y., Aurich, V., Bauer, C., Beck, A., Becker, C., Beichel, R., Bekes, G., et al. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2013851 · Cited by 1,135
Fast free-form deformation using graphics processing units
Modat, M., Ridgway, G. R., Taylor, Z. A., Lehmann, M., Barnes, J., Hawkes, D. J., Fox, N. C., & Ourselin, S. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.09.002 · Cited by 1,085
Metadata
- Authors
- Mattes, D., Haynor, D. R., Vesselle, H., Lewellen, T. K., & Eubank, W.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2003-01
- Volume
- 22
- Issue
- 1
- Pages
- 120-128
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2157380596
- Cited by
- 871
- References
- 35
- FWCI
- 28.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.