The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
PET-CT image registration in the chest using free-form deformations
Abstract
We have implemented and validated an algorithm for three-dimensional positron emission tomography transmission-to-computed tomography registration in the chest, using mutual information as a similarity criterion. Inherent differences in the two imaging protocols produce significant nonrigid motion between the two acquisitions. A rigid body deformation combined with localized cubic B-splines is used to capture this motion. The deformation is defined on a regular grid and is parameterized by potentially several thousand coefficients. Together with a spline-based continuous representation of images and Parzen histogram estimates, our deformation model allows closed-form expressions for the criterion and its gradient. A limited-memory quasi-Newton optimization algorithm is used in a hierarchical multiresolution framework to automatically align the images. To characterize the performance of the method, 27 scans from patients involved in routine lung cancer staging were used in a validation study. The registrations were assessed visually by two expert observers in specific anatomic locations using a split window validation technique. The visually reported errors are in the 0- to 6-mm range and the average computation time is 100 min on a moderate-performance workstation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
A survey of image registration techniques
Brown, L. G. (1992) · ACM Computing Surveys · doi:10.1145/146370.146374 · Cited by 4,057
Algorithm 778: L-BFGS-B: Fortran subroutines for large-scale bound-constrained optimization
Zhu, C., Byrd, R. H., Lu, P., & Nocedal, J. (1997) · ACM Transactions on Mathematical Software · doi:10.1145/279232.279236 · Cited by 3,462
Alignment by Maximization of Mutual Information
Viola, P., & Wells III, W. M. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007958904918 · Cited by 2,610
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
Automated Image Registration: II. Intersubject Validation of Linear and Nonlinear Models
Woods, R. P., Grafton, S. T., Watson, J. D. G., Sicotte, N. L., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00028 · Cited by 994
B-spline signal processing. I. Theory
Unser, M., Aldroubi, A., & Eden, M. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193220 · Cited by 940
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Cited by
3D Slicer as an image computing platform for the Quantitative Imaging Network
Fedorov, A., Beichel, R., Kalpathy-Cramer, J., Finet, J., Fillion-Robin, J.-C., Pujol, S., Bauer, C., Jennings, D., Fennessy, F., Sonka, M., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.05.001 · Cited by 9,023
A reproducible evaluation of ANTs similarity metric performance in brain image registration
Avants, B. B., Tustison, N. J., Song, G., Cook, P. A., Klein, A., & Gee, J. C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.025 · Cited by 4,796
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Comparison and evaluation of methods for liver segmentation from CT datasets
Heimann, T., van Ginneken, B., Styner, M. A., Arzhaeva, Y., Aurich, V., Bauer, C., Beck, A., Becker, C., Beichel, R., Bekes, G., et al. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2013851 · Cited by 1,135
Fast free-form deformation using graphics processing units
Modat, M., Ridgway, G. R., Taylor, Z. A., Lehmann, M., Barnes, J., Hawkes, D. J., Fox, N. C., & Ourselin, S. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.09.002 · Cited by 1,085
Medical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
Non-rigid image registration: theory and practice
Crum, W. R., Hartkens, T., & Hill, D. L. G. (2004) · The British Journal of Radiology · doi:10.1259/bjr/25329214 · Cited by 719
Serial two-photon tomography for automated ex vivo mouse brain imaging
Ragan, T., Kadiri, L. R., Venkataraju, K. U., Bahlmann, K., Sutin, J., Taranda, J., Arganda-Carreras, I., Kim, Y., Seung, H. S., & Osten, P. (2012) · Nature Methods · doi:10.1038/nmeth.1854 · Cited by 669
Fast parallel image registration on CPU and GPU for diagnostic classification of Alzheimer's disease
Shamonin, D. (2013) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2013.00050 · Cited by 586
Computer analysis of computed tomography scans of the lung: a survey
Sluimer, I., Schilham, A., Prokop, M., & van Ginneken, B. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.862753 · Cited by 556
Overview of image-guided radiation therapy
Xing, L., Thorndyke, B., Schreibmann, E., Yang, Y., Li, T.-F., Kim, G.-Y., Luxton, G., & Koong, A. (2006) · Medical Dosimetry · doi:10.1016/j.meddos.2005.12.004 · Cited by 468
Klein, S., Staring, M., & Pluim, J. P. W. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.909412 · Cited by 431
MacNeil, J. A., & Boyd, S. K. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.11.002 · Cited by 386
A Review of Geometric Transformations for Nonrigid Body Registration
Holden, M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.904691 · Cited by 369
Isgum, I., Staring, M., Rutten, A., Prokop, M., Viergever, M. A., & van Ginneken, B. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2011480 · Cited by 361
Results of a Multi-Institution Deformable Registration Accuracy Study (MIDRAS)
Brock, K. K. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.06.031 · Cited by 358
Dissociating the Role of Ventral and Dorsal Premotor Cortex in Precision Grasping
Davare, M., Andres, M., Cosnard, G., Thonnard, J.-L., & Olivier, E. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.3386-05.2006 · Cited by 346
Handbook of Mathematical Methods in Imaging
(2011) · Springer eBooks · doi:10.1007/978-0-387-92920-0 · Cited by 334
Elastic Registration of Biological Images Using Vector-Spline Regularization
Sorzano, C. O. S., Thevenaz, P., & Unser, M. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.844030 · Cited by 323
Mapping Social Behavior-Induced Brain Activation at Cellular Resolution in the Mouse
Kim, Y., Venkataraju, K. U., Pradhan, K., Mende, C., Taranda, J., Turaga, S. C., Arganda-Carreras, I., Ng, L., Hawrylycz, M. J., Rockland, K. S., et al. (2015) · Cell Reports · doi:10.1016/j.celrep.2014.12.014 · Cited by 302
Trebeschi, S., van Griethuysen, J. J. M., Lambregts, D. M. J., Lahaye, M. J., Parmar, C., Bakers, F. C. H., Peters, N. H. G. M., Beets-Tan, R. G. H., & Aerts, H. J. W. L. (2017) · Scientific Reports · doi:10.1038/s41598-017-05728-9 · Cited by 292
Fast free-form deformable registration via calculus of variations
Lu, W., Chen, M.-L., Olivera, G. H., Ruchala, K. J., & Mackie, T. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/14/003 · Cited by 259
A survey of methods for 3D histology reconstruction
Pichat, J., Iglesias, J. E., Yousry, T., Ourselin, S., & Modat, M. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.02.004 · Cited by 207
Unbiased Groupwise Registration of White Matter Tractography
O’Donnell, L. J., Wells, W. M., Golby, A. J., & Westin, C.-F. (2012) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-33454-2_16 · Cited by 112
Tatli, S., Gerbaudo, V. H., Mamede, M., Tuncali, K., Shyn, P. B., & Silverman, S. G. (2010) · Radiology · doi:10.1148/radiol.10090931 · Cited by 103
Robust and efficient linear registration of white-matter fascicles in the space of streamlines
Garyfallidis, E., Ocegueda, O., Wassermann, D., & Descoteaux, M. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.05.016 · Cited by 84
So, R. W. K., & Chung, A. C. S. (2017) · Pattern Recognition · doi:10.1016/j.patcog.2016.09.004 · Cited by 36
(2009) · doi:10.1007/978-3-642-04268-3_46 · Cited by 32
Deep Learning-Based X-ray Inpainting for Improving Spinal 2d-3d Registration
Esfandiari, H., Weidert, S., Kövesházi, I., Anglin, C., Street, J., & Hodgson, A. J. (2021) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.2228 · Cited by 12
Metadata
- Authors
- Mattes, D., Haynor, D. R., Vesselle, H., Lewellen, T. K., & Eubank, W.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2003-01
- Volume
- 22
- Issue
- 1
- Pages
- 120-128
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2157380596
- Cited by
- 871
- References
- 35
- FWCI
- 28.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.