Cone-beam reprojection using projection-matrices
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper addresses reprojection of three-dimensional (3-D) reconstructions obtained from cone-beam scans using a C-arm imaging equipment assisted by a pose-determining system. The emphasis is on reprojecting without decomposing the estimated projection matrix (P-matrix) associated with a pose. Both voxel- and ray-driven methods are considered. The voxel-driven reprojector follows the algorithm for backprojection using a P-matrix. The ray-driven reprojector is derived by extracting from the P-matrix the equation of the line joining a detector-pixel and the X-ray source position. This reprojector can be modified to a ray-driven backprojector. When the geometry is specified explicitly in terms of the physical parameters of the imaging system, the projection matrices can be constructed. The resulting "projection-matrix method" is advantageous, especially when the scanning trajectory is irregular. The algorithms presented are useful in iterative methods of image reconstruction and enhancement procedures, apart from their well-known role in visualization and volume rendering. Reprojections of 3-D patient data compare favorably with the original X-ray projections obtained from a prototype C-arm system. The algorithms for reprojection can be modified to compute perspective maximum intensity projection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
A comparison of similarity measures for use in 2-D-3-D medical image registration
Penney, G. P., Weese, J., Little, J. A., Desmedt, P., Hill, D. L. G., & hawkes, D. J. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730403 · Cited by 782
3D reconstruction from projection matrices in a C-arm based 3D-angiography system
Navab, N., Bani-Hashemi, A., Nadar, M. S., Wiesent, K., Durlak, P., Brunner, T., Barth, K., & Graumann, R. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056194 · Cited by 50 · cited 2×
“However, such a decomposition is neither necessary, nor desirable due to numerical instability of the process [22], [ 34 ].”
BackgroundMethodSelf-citation
Cited by
3D Forward and Back-Projection for X-Ray CT Using Separable Footprints
Long, Y., Fessler, J. A., & Balter, J. M. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2050898 · Cited by 228
3D-2D Registration for Surgical Guidance: Effect of Projection View Angles on Registration Accuracy
Uneri, A., Otake, Y., Wang, A. S., Kleinszig, G., Vogt, S., Khanna, A. J., & Siewerdsen, J. H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/2/271 · Cited by 53
4D interventional device reconstruction from biplane fluoroscopy
Wagner, M., Schafer, S., Strother, C., & Mistretta, C. (2016) · Medical Physics · doi:10.1118/1.4941950 · Cited by 48
X-Ray PoseNet: 6 DoF Pose Estimation for Mobile X-Ray Devices
Bui, M., Albarqouni, S., Schrapp, M., Navab, N., & Ilic, S. (2017) · 2017 IEEE Winter Conference on Applications of Computer Vision (WACV) · doi:10.1109/wacv.2017.120 · Cited by 27
Metadata
- Authors
- Galigekere, R. R., Wiesent, K., & Holdsworth, D. W.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2003-10
- Volume
- 22
- Issue
- 10
- Pages
- 1202-1214
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2111338112
- Cited by
- 59
- References
- 3
- FWCI
- 1.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cone-beam reprojection using projection-matrices. https://app.cochat.ai/papers/10.1109/tmi.2003.817787
- The paper
- Galigekere, R. R., Wiesent, K., & Holdsworth, D. W. (2003). Cone-beam reprojection using projection-matrices. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2003.817787
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.