The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
The adaptive bases algorithm for intensity-based nonrigid image registration
Abstract
Nonrigid registration of medical images is important for a number of applications such as the creation of population averages, atlas-based segmentation, or geometric correction of functional magnetic resonance imaging (fMRI) images to name a few. In recent years, a number of methods have been proposed to solve this problem, one class of which involves maximizing a mutual information (MI)-based objective function over a regular grid of splines. This approach has produced good results but its computational complexity is proportional to the compliance of the transformation required to register the smallest structures in the image. Here, we propose a method that permits the spatial adaptation of the transformation's compliance. This spatial adaptation allows us to reduce the number of degrees of freedom in the overall transformation, thus speeding up the process and improving its convergence properties. To develop this method, we introduce several novelties: 1) we rely on radially symmetric basis functions rather than B-splines traditionally used to model the deformation field; 2) we propose a metric to identify regions that are poorly registered and over which the transformation needs to be improved; 3) we partition the global registration problem into several smaller ones; and 4) we introduce a new constraint scheme that allows us to produce transformations that are topologically correct. We compare the approach we propose to more traditional ones and show that our new algorithm compares favorably to those in current use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 3×
“Prior to applying our algorithm, each volume was registered to the target volume using a nine DOFs transformation computed with an independent implementation of an MI-based method similar to the one proposed by Maes [8].”
MethodAutomatic 3D intersubject registration of MR volumetric data in standardized Talairach space
Collins, D. L., Neelin, P., Peters, T. M., & Evans, A. C. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199403000-00005 · Cited by 3,431 · cited 1×
“For instance (a more complete review on the subject can be found in [1]), Collins [2] proposes a technique in which the overall transformation is obtained as a set of local affine ones.”
BackgroundA survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
Multi-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,959
Interpolation of Scattered Data: Distance Matrices and Conditionally Positive Definite Functions
Micchelli, C. A. (1984) · Approximation Theory and Spline Functions · doi:10.1007/978-94-009-6466-2_7 · Cited by 1,297
Morphometric analysis of white matter lesions in MR images: method and validation
Zijdenbos, A. P., Dawant, B. M., Margolin, R. A., & Palmer, A. C. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363096 · Cited by 1,265
Self-citationInterpolation of scattered data: Distance matrices and conditionally positive definite functions
Micchelli, C. A. (1986) · Constructive Approximation · doi:10.1007/bf01893414 · Cited by 1,247
Cited by
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“[125] applied the Wu functions in image registration and derived bounds for”
MethodMulti-atlas segmentation of biomedical images: A survey
Iglesias, J. E., & Sabuncu, M. R. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.06.012 · Cited by 667
Dopaminergic mechanisms of individual differences in human effort-based decision-making
Treadway, M. T., Buckholtz, J. W., Cowan, R. L., Woodward, N. D., Li, R., Ansari, M. S., Baldwin, R. M., Schwartzman, A. N., Kessler, R. M., & Zald, D. H. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.6459-11.2012 · Cited by 385
Longitudinal changes in cortical thickness associated with normal aging
Thambisetty, M., Wan, J., Carass, A., An, Y., Prince, J. L., & Resnick, S. M. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.04.258 · Cited by 341
Brain Functional Localization: A Survey of Image Registration Techniques
Gholipour, A., Kehtarnavaz, N., Briggs, R., Devous, M., & Gopinath, K. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.892508 · Cited by 274
Limits to anatomical accuracy of diffusion tractography using modern approaches
Schilling, K. G., Nath, V., Hansen, C., Parvathaneni, P., Blaber, J., Gao, Y., Neher, P., Aydogan, D. B., Shi, Y., Ocampo-Pineda, M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.10.029 · Cited by 260
Evaluation of segmentation methods on head and neck CT: Auto‐segmentation challenge 2015
Raudaschl, P. F., Zaffino, P., Sharp, G. C., Spadea, M. F., Chen, A., Dawant, B. M., Albrecht, T., Gass, T., Langguth, C., Lüthi, M., et al. (2017) · Medical Physics · doi:10.1002/mp.12197 · Cited by 259
Self-citationA survey of methods for 3D histology reconstruction
Pichat, J., Iglesias, J. E., Yousry, T., Ourselin, S., & Modat, M. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.02.004 · Cited by 207
Histological validation of diffusion MRI fiber orientation distributions and dispersion
Schilling, K. G., Janve, V., Gao, Y., Stepniewska, I., Landman, B. A., & Anderson, A. W. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.046 · Cited by 195
“1H) using mutual information based 2D linear registration followed by 2D nonlinear registration using the adaptive bases algorithm (ABA) (Rohde et al., 2003).”
Dunn, J. P., Kessler, R. M., Feurer, I. D., Volkow, N. D., Patterson, B. W., Ansari, M. S., Li, R., Marks-Shulman, P., & Abumrad, N. N. (2012) · Diabetes Care · doi:10.2337/dc11-2250 · Cited by 148
“Parametric images of DA D2R were coregistered across all subjects with an elastic deformation algorithm (19).”
MethodKessler, R. M., Woodward, N. D., Riccardi, P., Li, R., Ansari, M. S., Anderson, S., Dawant, B., Zald, D., & Meltzer, H. Y. (2009) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.12.029 · Cited by 136
Self-citationAmphetamine-induced displacement of [18F] fallypride in striatum and extrastriatal regions in humans
Riccardi, P., Li, R., Ansari, M. S., Zald, D., Park, S., Dawant, B., Anderson, S., Doop, M., Woodward, N., Schoenberg, E., et al. (2006) · Neuropsychopharmacology · doi:10.1038/sj.npp.1300916 · Cited by 134
Self-citationD’Haese, P.-F., Ranjan, M., Song, A., Haut, M. W., Carpenter, J., Dieb, G., Najib, U., Wang, P., Mehta, R. I., Chazen, J. L., et al. (2020) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.593672 · Cited by 94
Chakravorti, S., Jermakowicz, W. J., Wu, C., Li, R., Wirz Gonzalez, R., Dawant, B. M., & D'Haese, P.-F. (2019) · Medical Imaging 2019: Image-Guided Procedures, Robotic Interventions, and Modeling · doi:10.1117/12.2512587 · Cited by 3
Self-citation
Metadata
- Authors
- Rohde, G. K., Aldroubi, A., & Dawant, B. M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2003-11
- Volume
- 22
- Issue
- 11
- Pages
- 1470-1479
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2142568997
- Cited by
- 402
- References
- 24
- FWCI
- 21.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.