The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Spatio-temporal nonrigid registration for ultrasound cardiac motion estimation
Open accessAbstract
We propose a new spatio-temporal elastic registration algorithm for motion reconstruction from a series of images. The specific application is to estimate displacement fields from two-dimensional ultrasound sequences of the heart. The basic idea is to find a spatio-temporal deformation field that effectively compensates for the motion by minimizing a difference with respect to a reference frame. The key feature of our method is the use of a semi-local spatio-temporal parametric model for the deformation using splines, and the reformulation of the registration task as a global optimization problem. The scale of the spline model controls the smoothness of the displacement field. Our algorithm uses a multiresolution optimization strategy to obtain a higher speed and robustness. We evaluated the accuracy of our algorithm using a synthetic sequence generated with an ultrasound simulation package, together with a realistic cardiac motion model. We compared our new global multiframe approach with a previous method based on pairwise registration of consecutive frames to demonstrate the benefits of introducing temporal consistency. Finally, we applied the algorithm to the regional analysis of the left ventricle. Displacement and strain parameters were evaluated showing significant differences between the normal and pathological segments, thereby illustrating the clinical applicability of our method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations for Quantitation of the Left Ventricle by Two-Dimensional Echocardiography
Schiller, N. B., Shah, P. M., Crawford, M., DeMaria, A., Devereux, R., Feigenbaum, H., Gutgesell, H., Reichek, N., Sahn, D., Schnittger, I., et al. (1989) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(89)80014-8 · Cited by 8,121
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
A pyramid approach to subpixel registration based on intensity
Thevenaz, P., Ruttimann, U. E., & Unser, M. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.650848 · Cited by 3,078
Self-citationCalculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers
Jensen, J. A., & Svendsen, N. B. (1992) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.139123 · Cited by 2,493
Boone, K. G., & Holder, D. S. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02520003 · Cited by 1,919
Hoffmann, R., Lethen, H., Marwick, T., Arnese, M., Fioretti, P., Pingitore, A., Picano, E., Buck, T., Erbel, R., Flachskampf, F. A., et al. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00483-1 · Cited by 589
Fast B-spline transforms for continuous image representation and interpolation
Unser, M. A., Aldroubi, A., & Eden, M. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.75515 · Cited by 528
Self-citationFast parametric elastic image registration
Kybic, J., & Unser, M. (2003) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.813139 · Cited by 477
Self-citationKonofagou, E., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00109-4 · Cited by 444
Moore, C. C., Lugo-Olivieri, C. H., McVeigh, E. R., & Zerhouni, E. A. (2000) · Radiology · doi:10.1148/radiology.214.2.r00fe17453 · Cited by 421
A review of cardiac image registration methods
Makela, T., Clarysse, P., Sipila, O., Pauna, N., Pham, Q. C., Katila, T., & Magnin, I. E. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.804441 · Cited by 361
Hein, I. A., & O'Brien, W. D. (1993) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.212556 · Cited by 309
Automatic segmentation of echocardiographic sequences by active appearance motion models
Bosch, J. G., Mitchell, S. C., Lelieveldt, B. P. F., Nijland, F., Kamp, O., Sonka, M., & Reiber, J. H. C. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806427 · Cited by 296
Spline-Based Image Registration
Szeliski, R., & Coughlan, J. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007996332012 · Cited by 255
Mikic, I., Krucinski, S., & Thomas, J. D. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700739 · Cited by 246
Recursive regularization filters: design, properties, and applications
Unser, M., Aldroubi, A., & Eden, M. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.75514 · Cited by 193
Self-citationUltrasonic texture motion analysis: theory and simulation
Meunier, J., & Bertrand, M. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.387711 · Cited by 191
Spatio-temporal alignment of sequences
Caspi, Y., & Irani, M. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2002.1046148 · Cited by 185
Myocardial motion analysis from B-mode echocardiograms
Sühling, M., Arigovindan, M., Jansen, C. H. P., Hunziker, P., & Unser, M. A. (2005) · IEEE Transactions on Image Processing · doi:10.1109/tip.2004.838709 · Cited by 171
Self-citationDumesnil, J. G., Shoucri, R. M., Laurenceau, J. L., & Turcot, J. (1979) · Circulation · doi:10.1161/01.cir.59.5.1024 · Cited by 159
Jacob, G., Noble, J. A., Behrenbruch, C., Kelion, A. D., & Banning, A. P. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.996341 · Cited by 142 · cited 1×
“the intrinsic complexity of the data by introducing a priori knowledge by modeling a statistical representation of the possible motions and shapes [24], [25].”
BackgroundThe L/sub 2/-polynomial spline pyramid
Unser, M. A., Aldroubi, A., & Eden, M. (1993) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.206956 · Cited by 141
Self-citationFeature-adaptive motion tracking of ultrasound image sequences using a deformable mesh
Yeung, F., Levinson, S. F., Fu, D., & Parker, K. J. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.746627 · Cited by 126
New maximum likelihood motion estimation schemes for noisy ultrasound images
Cohen, B., & Dinstein, I. (2002) · Pattern Recognition · doi:10.1016/s0031-3203(01)00053-x · Cited by 117
Declerck, J. M., Feldmar, J., Goris, M. L., & Betting, F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650870 · Cited by 102
Velocity Estimation in Ultrasound Images: A Block Matching Approach
Boukerroui, D., Noble, J. A., & Brady, M. (2003) · Lecture notes in computer science · doi:10.1007/978-3-540-45087-0_49 · Cited by 97
Andersen, N. H., & Poulsen, S. H. (2003) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(03)00325-0 · Cited by 84
Four-dimensional processing of deformable cardiac PET data
Klein, G. J., & Huesman, R. H. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00050-0 · Cited by 75
Herbots, L., Maes, F., D’hooge, J., Claus, P., Dymarkowski, S., Mertens, P., Mortelmans, L., Bijnens, B. H., Bogaert, J. G., Rademakers, F. E., et al. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.02.003 · Cited by 56
On-line analysis of echocardiographic image sequences
Giachetti, A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80023-6 · Cited by 34
Noble, J. A., Dawson, D. K., Lindner, J. R., Sklenar, J., & Kaul, S. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00461-6 · Cited by 16
Cited by
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
Medical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
Xu, L., Liu, M., Shen, Z., Wang, H., Liu, X., Wang, X., Wang, S., Li, T., Yu, S., Hou, M., et al. (2020) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2019.101690 · Cited by 87
Metadata
- Authors
- Ledesma-Carbayo, M. J., Kybic, J., Desco, M., Santos, A., Suhling, M., Hunziker, P., & Unser, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2005-09
- Volume
- 24
- Issue
- 9
- Pages
- 1113-1126
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2127735446
- Cited by
- 290
- References
- 32
- FWCI
- 19.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.