3-D/2-D registration by integrating 2-D information in 3-D
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
In image-guided therapy, high-quality preoperative images serve for planning and simulation, and intraoperatively as "background", onto which models of surgical instruments or radiation beams are projected. The link between a preoperative image and intraoperative physical space of the patient is established by image-to-patient registration. In this paper, we present a novel 3-D/2-D registration method. First, a 3-D image is reconstructed from a few 2-D X-ray images and next, the preoperative 3-D image is brought into the best possible spatial correspondence with the reconstructed image by optimizing a similarity measure (SM). Because the quality of the reconstructed image is generally low, we introduce a novel SM, which is able to cope with low image quality as well as with different imaging modalities. The novel 3-D/2-D registration method has been evaluated and compared to the gradient-based method (GBM) using standardized evaluation methodology and publicly available 3-D computed tomography (CT), 3-D rotational X-ray (3DRX), and magnetic resonance (MR) and 2-D X-ray images of two spine phantoms, for which gold standard registrations were known. For each of the 3DRX, CT, or MR images and each set of X-ray images, 1600 registrations were performed from starting positions, defined as the mean target registration error (mTRE), randomly generated and uniformly distributed in the interval of 0-20 mm around the gold standard. The capture range was defined as the distance from gold standard for which the final TRE was less than 2 mm in at least 95% of all cases. In terms of success rate, as the function of initial misalignment and capture range the proposed method outperformed the GBM. TREs of the novel method and the GBM were approximately the same. For the registration of 3DRX and CT images to X-ray images as few as 2-3 X-ray views were sufficient to obtain approximately 0.4 mm TREs, 7-9 mm capture range, and 80%-90% of successful registrations. To obtain similar results for MR to X-ray registrations, an image, reconstructed from at least 11 X-ray images was required. Reconstructions from more than 11 images had no effect on the registration results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elements of Information Theory
Cover, T. M., & Thomas, J. A. (2005) · doi:10.1002/047174882x · Cited by 13,791
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 2×
“As in single-feature mutual information, the multivariate probability distributions can be estimated from joint histograms [28].”
MethodA comparison of similarity measures for use in 2-D-3-D medical image registration
Penney, G. P., Weese, J., Little, J. A., Desmedt, P., Hill, D. L. G., & hawkes, D. J. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730403 · Cited by 782
Evaluation of Intensity-Based 2D-3D Spine Image Registration Using Clinical Gold-Standard Data
Russakoff, D. B., Rohlfing, T., Ho, A., Kim, D. H., Shahidi, R., Adler, J. R., & Maurer, C. R. (2003) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-39701-4_16 · Cited by 43
“Gold standard” data for evaluation and comparison of 3D/2D registration methods
Tomaževič, D., Likar, B., & Pernuš, F. (2004) · Computer Aided Surgery · doi:10.3109/10929080500097687 · Cited by 40
Self-citation
Cited by
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
“D image reconstructed from only a few fluoroscopic X-ray images, a robust mutual information based similarity measure, called asymmetric multi-feature mutual information, that used additional spatial features in the form of intensity gradients was proposed (Tomaževič et al., 2006).”
BackgroundMethodInfluentialSelf-citationA Review of Recent Advances in Registration Techniques Applied to Minimally Invasive Therapy
Liao, R., Zhang, L., Sun, Y., Miao, S., & Chefd'Hotel, C. (2013) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2013.2244869 · Cited by 71
“Both feature-based [29] and gradient-based [101], [168] methods have”
MethodBirkfellner, W., Stock, M., Figl, M., Gendrin, C., Hummel, J., Dong, S., Kettenbach, J., Georg, D., & Bergmann, H. (2009) · Medical Physics · doi:10.1118/1.3157111 · Cited by 44
Registration of 2D x-ray images to 3D MRI by generating pseudo-CT data
van der Bom, M. J., Pluim, J. P. W., Gounis, M. J., van de Kraats, E. B., Sprinkhuizen, S. M., Timmer, J., Homan, R., & Bartels, L. W. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/010 · Cited by 21
Metadata
- Authors
- Tomazevic, D., Likar, B., & Pernus, F.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2006-01
- Volume
- 25
- Issue
- 1
- Pages
- 17-27
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2089250838
- Cited by
- 80
- References
- 6
- FWCI
- 8.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3-D/2-D registration by integrating 2-D information in 3-D. https://app.cochat.ai/papers/10.1109/tmi.2005.859715
- The paper
- Tomazevic, D., Likar, B., & Pernus, F. (2006). 3-D/2-D registration by integrating 2-D information in 3-D. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2005.859715
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.