The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Retinal Vessel Centerline Extraction Using Multiscale Matched Filters, Confidence and Edge Measures
Abstract
Motivated by the goals of improving detection of low-contrast and narrow vessels and eliminating false detections at nonvascular structures, a new technique is presented for extracting vessels in retinal images. The core of the technique is a new likelihood ratio test that combines matched-filter responses, confidence measures and vessel boundary measures. Matched filter responses are derived in scale-space to extract vessels of widely varying widths. A vessel confidence measure is defined as a projection of a vector formed from a normalized pixel neighborhood onto a normalized ideal vessel profile. Vessel boundary measures and associated confidences are computed at potential vessel boundaries. Combined, these responses form a six-dimensional measurement vector at each pixel. A training technique is used to develop a mapping of this vector to a likelihood ratio that measures the "vesselness" at each pixel. Results comparing this vesselness measure to matched filters alone and to measures based on the Hessian of intensities show substantial improvements, both qualitatively and quantitatively. The Hessian can be used in place of the matched filter to obtain similar but less-substantial improvements or to steer the matched filter by preselecting kernel orientations. Finally, the new vesselness likelihood ratio is embedded into a vessel tracing framework, resulting in an efficient and effective vessel centerline extraction algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
Fundamentals of Statistical Signal Processing: Estimation Theory
Sengijpta, S. K. (1995) · Technometrics · doi:10.1080/00401706.1995.10484391 · Cited by 11,076
Russell, E. L., Chiang, L. H., & Braatz, R. D. (2000) · Advances in Industrial Control · doi:10.1007/978-1-4471-0409-4_3 · Cited by 7,862
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Multiscale vessel enhancement filtering
Frangi, A. F., Niessen, W. J., Vincken, K. L., & Viergever, M. A. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056195 · Cited by 3,707
The design and use of steerable filters
Freeman, W. T., & Adelson, E. H. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.93808 · Cited by 2,942
Prevalence of Age-Related Macular Degeneration in the United States
(2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.564 · Cited by 2,736
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Hoover, A. D., Kouznetsova, V., & Goldbaum, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845178 · Cited by 2,582
Feature detection with automatic scale selection
Lindeberg, T. (1998) · International Journal of Computer Vision · doi:10.1023/a:1008045108935 · Cited by 2,541 · cited 1×
“where g(·; t) is a Gaussian function with variance t, f is an image,(x, y) is a pixel location, and∗ represents the convolution operation [59].”
Background
Cited by
Blood vessel segmentation methodologies in retinal images – A survey
Fraz, M. M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Rudnicka, A. R., Owen, C. G., & Barman, S. A. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2012.03.009 · Cited by 1,001
Robust Vessel Segmentation in Fundus Images
Budai, A., Bock, R., Maier, A., Hornegger, J., & Michelson, G. (2013) · International Journal of Biomedical Imaging · doi:10.1155/2013/154860 · Cited by 642
An effective retinal blood vessel segmentation method using multi-scale line detection
Nguyen, U. T. V., Bhuiyan, A., Park, L. A. F., & Ramamohanarao, K. (2013) · Pattern Recognition · doi:10.1016/j.patcog.2012.08.009 · Cited by 479
A review of biometric technology along with trends and prospects
Unar, J. A., Seng, W. C., & Abbasi, A. (2014) · Pattern Recognition · doi:10.1016/j.patcog.2014.01.016 · Cited by 404
Segmentation of retinal blood vessels using the radial projection and semi-supervised approach
You, X., Peng, Q., Yuan, Y., Cheung, Y.-M., & Lei, J. (2011) · Pattern Recognition · doi:10.1016/j.patcog.2011.01.007 · Cited by 387
Glaucoma risk index:Automated glaucoma detection from color fundus images
Bock, R., Meier, J., Nyúl, L. G., Hornegger, J., & Michelson, G. (2010) · Medical Image Analysis · doi:10.1016/j.media.2009.12.006 · Cited by 361
FABC: Retinal Vessel Segmentation Using AdaBoost
Lupascu, C. A., Tegolo, D., & Trucco, E. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2052282 · Cited by 352
An approach to localize the retinal blood vessels using bit planes and centerline detection
Fraz, M. M., Barman, S. A., Remagnino, P., Hoppe, A., Basit, A., Uyyanonvara, B., Rudnicka, A. R., & Owen, C. G. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2011.08.009 · Cited by 340
An Automatic Detection System of Lung Nodule Based on Multigroup Patch-Based Deep Learning Network
Jiang, H., Ma, H., Qian, W., Gao, M., & Li, Y. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2725903 · Cited by 280
General Retinal Vessel Segmentation Using Regularization-Based Multiconcavity Modeling
Lam, B. S. Y., Gao, Y., & Liew, A. W.-C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2043259 · Cited by 275
Multiscale AM-FM Methods for Diabetic Retinopathy Lesion Detection
Agurto, C., Murray, V., Barriga, E., Murillo, S., Pattichis, M., Davis, H., Russell, S., Abramoff, M., & Soliz, P. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2037146 · Cited by 259
Metadata
- Authors
- Sofka, M., & Stewart, C. V.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2006-12
- Volume
- 25
- Issue
- 12
- Pages
- 1531-1546
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2114240017
- Cited by
- 334
- References
- 56
- FWCI
- 10.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.