The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Retinal Vessel Centerline Extraction Using Multiscale Matched Filters, Confidence and Edge Measures
Abstract
Motivated by the goals of improving detection of low-contrast and narrow vessels and eliminating false detections at nonvascular structures, a new technique is presented for extracting vessels in retinal images. The core of the technique is a new likelihood ratio test that combines matched-filter responses, confidence measures and vessel boundary measures. Matched filter responses are derived in scale-space to extract vessels of widely varying widths. A vessel confidence measure is defined as a projection of a vector formed from a normalized pixel neighborhood onto a normalized ideal vessel profile. Vessel boundary measures and associated confidences are computed at potential vessel boundaries. Combined, these responses form a six-dimensional measurement vector at each pixel. A training technique is used to develop a mapping of this vector to a likelihood ratio that measures the "vesselness" at each pixel. Results comparing this vesselness measure to matched filters alone and to measures based on the Hessian of intensities show substantial improvements, both qualitatively and quantitatively. The Hessian can be used in place of the matched filter to obtain similar but less-substantial improvements or to steer the matched filter by preselecting kernel orientations. Finally, the new vesselness likelihood ratio is embedded into a vessel tracing framework, resulting in an efficient and effective vessel centerline extraction algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
Fundamentals of Statistical Signal Processing: Estimation Theory
Sengijpta, S. K. (1995) · Technometrics · doi:10.1080/00401706.1995.10484391 · Cited by 11,076
Russell, E. L., Chiang, L. H., & Braatz, R. D. (2000) · Advances in Industrial Control · doi:10.1007/978-1-4471-0409-4_3 · Cited by 7,862
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Multiscale vessel enhancement filtering
Frangi, A. F., Niessen, W. J., Vincken, K. L., & Viergever, M. A. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056195 · Cited by 3,707
The design and use of steerable filters
Freeman, W. T., & Adelson, E. H. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.93808 · Cited by 2,942
Prevalence of Age-Related Macular Degeneration in the United States
(2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.564 · Cited by 2,736
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Hoover, A. D., Kouznetsova, V., & Goldbaum, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845178 · Cited by 2,582
Feature detection with automatic scale selection
Lindeberg, T. (1998) · International Journal of Computer Vision · doi:10.1023/a:1008045108935 · Cited by 2,541
Detection of blood vessels in retinal images using two-dimensional matched filters
Chaudhuri, S., Chatterjee, S., Katz, N., Nelson, M., & Goldbaum, M. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.34715 · Cited by 1,668
Hubbard, L. D., Brothers, R. J., King, W. N., Clegg, L. X., Klein, R., Cooper, L. S., Sharrett, A. R., Davis, M. D., & Cai, J. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90525-0 · Cited by 1,184
The Prevalence of Diabetic Retinopathy Among Adults in the United States
(2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.552 · Cited by 1,148
Prevalence of Open-Angle Glaucoma Among Adults in the United States
(2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.532 · Cited by 1,110
Edge Detection and Ridge Detection with Automatic Scale Selection
Lindeberg, T. (1998) · International Journal of Computer Vision · doi:10.1023/a:1008097225773 · Cited by 1,024
A review of vessel extraction techniques and algorithms
Kirbas, C., & Quek, F. (2004) · ACM Computing Surveys · doi:10.1145/1031120.1031121 · Cited by 900
Segmentation of vessel-like patterns using mathematical morphology and curvature evaluation
Zana, F., & Klein, J.-C. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.931095 · Cited by 862
Walter, T., Klein, J., Massin, P., & Erginay, A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806290 · Cited by 825
Comparative study of retinal vessel segmentation methods on a new publicly available database
Niemeijer, M., Staal, J., van Ginneken, B., Loog, M., & Abramoff, M. D. (2004) · SPIE Proceedings · doi:10.1117/12.535349 · Cited by 790
Locating the optic nerve in a retinal image using the fuzzy convergence of the blood vessels
Hoover, A., & Goldbaum, M. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815900 · Cited by 787
Jiang, X., & Mojon, D. (2003) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2003.1159954 · Cited by 679
Aylward, S. R., & Bullitt, E. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993126 · Cited by 578
Learning a Sparse Representation for Object Detection
Agarwal, S., & Roth, D. (2002) · Lecture Notes in Computer Science · doi:10.1007/3-540-47979-1_8 · Cited by 507
Detection of Optic Disc in Retinal Images by Means of a Geometrical Model of Vessel Structure
Foracchia, M., Grisan, E., & Ruggeri, A. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.829331 · Cited by 445
Can, A., Shen, H., Turner, Tanenbaum, & Roysam (1999) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.767088 · Cited by 434
Sato, Y., Nakajima, S., Atsumi, H., Koller, T., Gerig, G., Yoshida, S., & Kikinis, R. (1997) · Lecture Notes in Computer Science · doi:10.1007/bfb0029240 · Cited by 396
Edge detection with embedded confidence
Meer, P., & Georgescu, B. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.977560 · Cited by 377
A fuzzy vessel tracking algorithm for retinal images based on fuzzy clustering
Tolias, Y. A., & Panas, S. M. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700738 · Cited by 365
Heneghan, C. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00058-0 · Cited by 353
Sharrett, A. R., Hubbard, L. D., Cooper, L. S., Sorlie, P. D., Brothers, R. J., Nieto, F. J., Pinsky, J. L., & Klein, R. (1999) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a009997 · Cited by 348
The dual-bootstrap iterative closest point algorithm with application to retinal image registration
Stewart, C. V., Tsai, C.-L., & Roysam, B. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819276 · Cited by 346
Self-citationStatistical edge detection: learning and evaluating edge cues
Konishi, S., Yuille, A. L., Coughlan, J. M., & Zhu, S. C. (2003) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2003.1159946 · Cited by 338
Retinal arteriolar narrowing and risk of diabetes mellitus in middle-aged persons
Wong, T. Y. (2002) · JAMA · doi:10.1001/jama.287.19.2528 · Cited by 320 · cited 1×
“[7], image registration [8]–[14], change detection [15]–[21], pathology detection and quantification [22], tracking in video sequences [23]–[25], and computer-aided screening systems [26]– [29] depend on vessel extraction.”
BackgroundMultiscale detection of curvilinear structures in 2-D and 3-D image data
Koller, T. M., Gerig, G., Szekely, G., & Dettwiler, D. (2002) · Proceedings of IEEE International Conference on Computer Vision · doi:10.1109/iccv.1995.466846 · Cited by 314
A multimodal registration algorithm of eye fundus images using vessels detection and Hough transform
Zana, F., & Klein, J. C. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.774169 · Cited by 303
Gang, L., Chutatape, O., & Krishnan, S. M. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.979356 · Cited by 294
Can, A., Stewart, C. V., Roysam, B., & Tanenbaum, H. L. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.990136 · Cited by 272
Self-citationMeasurement of Retinal Vessel Widths From Fundus Images Based on 2-D Modeling
Lowell, J., Hunter, A., Steel, D., Basu, A., Ryder, R., & Kennedy, R. L. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.830524 · Cited by 255
Ridges in Image and Data Analysis
Eberly, D. (1996) · Computational Imaging and Vision · doi:10.1007/978-94-015-8765-5 · Cited by 250
Rapid automated three-dimensional tracing of neurons from confocal image stacks
Al-Kofahi, K. A., Lasek, S., Szarowski, D. H., Pace, C. J., Nagy, G., Turner, J. N., & Roysam, B. (2002) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2002.1006304 · Cited by 237
Pinz, A., Bernogger, S., Datlinger, P., & Kruger, A. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730405 · Cited by 233
Retinal thickness measurements from optical coherence tomography using a Markov boundary model
Koozekanani, D., Boyer, K., & Roberts, C. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.952728 · Cited by 231
Retinal Blood Vessel Segmentation by Means of Scale-Space Analysis and Region Growing
Martínez-Pérez, M. E., Hughes, A. D., Stanton, A. V., Thom, S. A., Bharath, A. A., & Parker, K. H. (1999) · Lecture Notes in Computer Science · doi:10.1007/10704282_10 · Cited by 200
Vascular network changes in the retina with age and hypertension.
Stanton, A. V., Wasan, B. S., Cerutti, A., Ford, S. R., Marsh, R. J., Sever, P., Thom, S., & Hughes, A. D. (1995) · PubMed · Cited by 200
Steerable wedge filters for local orientation analysis
Simoncelli, E. P., & Farid, H. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.535851 · Cited by 189
Teng, T., Lefley, M., & Claremont, D. (2002) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347689 · Cited by 179
Retinal vascular abnormalities in persons with type 1 diabetes
Klein, R., Klein, B. E. K., Moss, S. E., Wong, T. Y., Hubbard, L. D., Cruickshanks, K. J., & Palta, M. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00863-7 · Cited by 137
Tsai, C.-L., Stewart, C. V., Tanenbaum, H. L., & Roysam, B. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.826733 · Cited by 119
Self-citationMultimodal Registration of Retinal Images Using Self Organizing Maps
Matsopoulos, G. K., Asvestas, P. A., Mouravliansky, N. A., et al. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.836547 · Cited by 86
Robust Model-Based Vasculature Detection in Noisy Biomedical Images
Mahadevan, V. S., Narasimha-Iyer, H., Roysam, B., & Tanenbaum, H. L. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.834410 · Cited by 75
Properties of Ridges and Cores for Two-Dimensional Images
Damon, J. (1999) · Journal of Mathematical Imaging and Vision · doi:10.1023/a:1008379107611 · Cited by 51
Shen, H., Stewart, C. V., Roysam, B., Lin, G., & Tanenbaum, H. L. (2003) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2003.1182101 · Cited by 36
Self-citationA computational method for segmenting topological point-sets and application to image analysis
Kalitzin, S., Staal, J. J., Romeny, B. M. T. H., & Viergever, M. A. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.922704 · Cited by 24
Koozekanani, D. D., Boyer, K. L., & Roberts, C. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.817753 · Cited by 24
On the Influence of Scale Selection on Feature Detection for the Case of Linelike Structures
Majer, P. (2004) · International Journal of Computer Vision · doi:10.1023/b:visi.0000036834.42685.b6 · Cited by 10
A trained spin-glass model for grouping of image primitives
Staal, J. J., Kalitzin, S., & Viergever, M. A. (2005) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2005.131 · Cited by 10
Cited by
Blood vessel segmentation methodologies in retinal images – A survey
Fraz, M. M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Rudnicka, A. R., Owen, C. G., & Barman, S. A. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2012.03.009 · Cited by 1,001
Robust Vessel Segmentation in Fundus Images
Budai, A., Bock, R., Maier, A., Hornegger, J., & Michelson, G. (2013) · International Journal of Biomedical Imaging · doi:10.1155/2013/154860 · Cited by 642
An effective retinal blood vessel segmentation method using multi-scale line detection
Nguyen, U. T. V., Bhuiyan, A., Park, L. A. F., & Ramamohanarao, K. (2013) · Pattern Recognition · doi:10.1016/j.patcog.2012.08.009 · Cited by 479
A review of biometric technology along with trends and prospects
Unar, J. A., Seng, W. C., & Abbasi, A. (2014) · Pattern Recognition · doi:10.1016/j.patcog.2014.01.016 · Cited by 404
Segmentation of retinal blood vessels using the radial projection and semi-supervised approach
You, X., Peng, Q., Yuan, Y., Cheung, Y.-M., & Lei, J. (2011) · Pattern Recognition · doi:10.1016/j.patcog.2011.01.007 · Cited by 387
Metadata
- Authors
- Sofka, M., & Stewart, C. V.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2006-12
- Volume
- 25
- Issue
- 12
- Pages
- 1531-1546
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2114240017
- Cited by
- 334
- References
- 56
- FWCI
- 10.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.