The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Detection of Anatomic Structures in Human Retinal Imagery
Abstract
The widespread availability of electronic imaging devices throughout the medical community is leading to a growing body of research on image processing and analysis to diagnose retinal disease such as diabetic retinopathy (DR). Productive computer-based screening of large, at-risk populations at low cost requires robust, automated image analysis. In this paper we present results for the automatic detection of the optic nerve and localization of the macula using digital red-free fundus photography. Our method relies on the accurate segmentation of the vasculature of the retina followed by the determination of spatial features describing the density, average thickness, and average orientation of the vasculature in relation to the position of the optic nerve. Localization of the macula follows using knowledge of the optic nerve location to detect the horizontal raphe of the retina using a geometric model of the vasculature. We report 90.4% detection performance for the optic nerve and 92.5% localization performance for the macula for red-free fundus images representing a population of 345 images corresponding to 269 patients with 18 different pathologies associated with DR and other common retinal diseases such as age-related macular degeneration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Cited by
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Computer-aided diagnosis of diabetic retinopathy: A review
Mookiah, M. R. K., Acharya, U. R., Chua, C. K., Lim, C. M., Ng, E. Y. K., & Laude, A. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.10.007 · Cited by 430
Exudate-based diabetic macular edema detection in fundus images using publicly available datasets
Giancardo, L., Meriaudeau, F., Karnowski, T. P., Li, Y., Garg, S., Tobin, K. W., & Chaum, E. (2012) · Medical Image Analysis · doi:10.1016/j.media.2011.07.004 · Cited by 322
Self-citationGeneral Retinal Vessel Segmentation Using Regularization-Based Multiconcavity Modeling
Lam, B. S. Y., Gao, Y., & Liew, A. W.-C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2043259 · Cited by 275
A model of ganglion axon pathways accounts for percepts elicited by retinal implants
Beyeler, M., Nanduri, D., Weiland, J. D., Rokem, A., Boynton, G. M., & Fine, I. (2019) · Scientific Reports · doi:10.1038/s41598-019-45416-4 · Cited by 143
A model of ganglion axon pathways accounts for percepts elicited by retinal implants
Beyeler, M., Nanduri, D., Weiland, J. D., Rokem, A., Boynton, G. M., & Fine, I. (2018) · doi:10.1101/453035 · Cited by 13
Metadata
- Authors
- Tobin, K. W., Chaum, E., Govindasamy, V. P., & Karnowski, T. P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2007-12
- Volume
- 26
- Issue
- 12
- Pages
- 1729-1739
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2146898399
- Cited by
- 230
- References
- 2
- FWCI
- 7.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.