Fluid Registration of Diffusion Tensor Images Using Information Theory
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
We apply an information-theoretic cost metric, the symmetrized Kullback-Leibler (sKL) divergence, or J-divergence, to fluid registration of diffusion tensor images. The difference between diffusion tensors is quantified based on the sKL-divergence of their associated probability density functions (PDFs). Three-dimensional DTI data from 34 subjects were fluidly registered to an optimized target image. To allow large image deformations but preserve image topology, we regularized the flow with a large-deformation diffeomorphic mapping based on the kinematics of a Navier-Stokes fluid. A driving force was developed to minimize the J-divergence between the deforming source and target diffusion functions, while reorienting the flowing tensors to preserve fiber topography. In initial experiments, we showed that the sKL-divergence based on full diffusion PDFs is adaptable to higher-order diffusion models, such as high angular resolution diffusion imaging (HARDI). The sKL-divergence was sensitive to subtle differences between two diffusivity profiles, showing promise for nonlinear registration applications and multisubject statistical analysis of HARDI data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · cited 1×
“3-D Gaussian probability density function (PDF), whose spatial covariance can be approximated by a positive–definite secondorder symmetric tensor [27]”
BackgroundA Direct Approach to False Discovery Rates
Storey, J. D. (2002) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/1467-9868.00346 · Cited by 5,603
Tuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
Principles of diffusion tensor imaging and its applications to basic neuroscience research
Mori, S., & Zhang, J. (2006) · Neuron · doi:10.1016/j.neuron.2006.08.012 · Cited by 1,708
High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548 · cited 19×
“We compared the symmetrized KL-divergence with the inner product of diffusivity functions, (with the linear term) and (without the linear term), on synthetic examples that were noise-free, or with Rician noise added to MR signals such that the signal-to-noise ratio (SNR) was 35 or 10 [59].”
BackgroundMethodInfluentialHandbook of Parametric and Nonparametric Statistical Procedures
Sheskin, D. J. (1996) · CRC Press eBooks · doi:10.4324/9780203489536 · Cited by 910
Diffusion MRI of complex neural architecture.
Tuch, D. S., Reese, T. G., Wiegell, M. R., & Wedeen, V. J. (2003) · Neuron · doi:10.1016/s0896-6273(03)00758-x · Cited by 698
Spatial transformations of diffusion tensor magnetic resonance images
Alexander, D. C., Pierpaoli, C., Basser, P. J., & Gee, J. C. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.963816 · Cited by 610 · cited 5×
“For DTI, the tensor reorientation step has been well described in [22] and [36].”
BackgroundMethodInfluentialVariational Methods for Multimodal Image Matching
Hermosillo, G., Chefd'Hotel, C., & Faugeras, O. (2002) · International Journal of Computer Vision · doi:10.1023/a:1020830525823 · Cited by 388
Cited by
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“[37] proposed an inverse consistent variant of fluid registration to register Diffusion”
BackgroundMedical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
Oishi, K., Faria, A., Jiang, H., Li, X., Akhter, K., Zhang, J., Hsu, J. T., Miller, M. I., van Zijl, P. C. M., Albert, M., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.01.002 · Cited by 575
Self-citationNTU-90: A high angular resolution brain atlas constructed by q-space diffeomorphic reconstruction
Yeh, F.-C., & Tseng, W.-Y. I. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.021 · Cited by 507
Genetics of brain fiber architecture and intellectual performance
Chiang, M.-C., Barysheva, M., Shattuck, D. W., Lee, A. D., Madsen, S. K., Avedissian, C., Klunder, A. D., Toga, A. W., McMahon, K. L., de Zubicaray, G. I., et al. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.4184-08.2009 · Cited by 406
“…we registered all affine-registered DT images in (2) to a randomly selected subject’s DT image (a MZ subject), using an inverse-consistent fluid registration algorithm that minimizes the symmetrized Kullback–Leibler divergence (sKLdivergence) of the two tensor-valued images (Chiang et al., 2008).”
MethodSelf-citationDiffusion Imaging, White Matter, and Psychopathology
Thomason, M. E., & Thompson, P. M. (2011) · Annual Review of Clinical Psychology · doi:10.1146/annurev-clinpsy-032210-104507 · Cited by 305
Self-citationSymmetric diffeomorphic registration of fibre orientation distributions
Raffelt, D., Tournier, J.-D., Fripp, J., Crozier, S., Connelly, A., & Salvado, O. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.014 · Cited by 284
Visualization of image data from cells to organisms
Walter, T., Shattuck, D. W., Baldock, R., Bastin, M. E., Carpenter, A. E., Duce, S., Ellenberg, J., Fraser, A., Hamilton, N., Pieper, S., et al. (2010) · Nature Methods · doi:10.1038/nmeth.1431 · Cited by 266
THOMPSON, P. M., HAYASHI, K. M., DUTTON, R. A., CHIANG, M., LEOW, A. D., SOWELL, E. R., DE ZUBICARAY, G., BECKER, J. T., LOPEZ, O. L., AIZENSTEIN, H. J., et al. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1379.017 · Cited by 253
Self-citationSchwarz, C. G., Reid, R. I., Gunter, J. L., Senjem, M. L., Przybelski, S. A., Zuk, S. M., Whitwell, J. L., Vemuri, P., Josephs, K. A., Kantarci, K., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.03.026 · Cited by 171
“, 2010), Orientation Distribution Functions (Chiang et al., 2008), or tractography.”
Self-citationGenetics of microstructure of cerebral white matter using diffusion tensor imaging
Kochunov, P., Glahn, D. C., Lancaster, J. L., Winkler, A. M., Smith, S., Thompson, P. M., Almasy, L., Duggirala, R., Fox, P. T., & Blangero, J. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.01.078 · Cited by 159
“Hardware of MR scanners limits the spatial resolution of DTI data, therefore making intersubject voxelbased analysis susceptible to misalignment and partial-volume effects necessitating specialized processing (Chiang et al., 2008; Smith et al., 2006b).”
BackgroundSelf-citationDTI analyses and clinical applications in Alzheimer’s disease
Oishi, K., Mielke, M. M., Albert, M., Lyketsos, C. G., & Mori, S. (2011) · Journal of Alzheimer's Disease · doi:10.3233/jad-2011-0007 · Cited by 134
“some combination of these methods [71–75].”
Malinsky, M., Peter, R., Hodneland, E., Lundervold, A. J., Lundervold, A., & Jan, J. (2013) · Journal of Digital Imaging · doi:10.1007/s10278-012-9561-8 · Cited by 33
“According to publications mentioned in the introduction [6, 16, 17], the FA and T1 images were so far registered using either the ITK library or the Elastix.”
MethodQiu, A., Oishi, K., Miller, M. I., Lyketsos, C. G., Mori, S., & Albert, M. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009811 · Cited by 26
“Recent registration algorithms specialized for DTI have been developed and have shown to improve structural alignment when considering the tensor structure of DTI [11,12,13,14,15].”
Metadata
- Authors
- Chiang, M.-C., Leow, A. D., Klunder, A. D., Dutton, R. A., Barysheva, M., Rose, S. E., McMahon, K. L., de Zubicaray, G. I., Toga, A. W., & Thompson, P. M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2008-04
- Volume
- 27
- Issue
- 4
- Pages
- 442-456
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2138144081
- Cited by
- 110
- References
- 11
- FWCI
- 13.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.