The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Multi-Atlas-Based Segmentation With Local Decision Fusion—Application to Cardiac and Aortic Segmentation in CT Scans
Open accessAbstract
A novel atlas-based segmentation approach based on the combination of multiple registrations is presented. Multiple atlases are registered to a target image. To obtain a segmentation of the target, labels of the atlas images are propagated to it. The propagated labels are combined by spatially varying decision fusion weights. These weights are derived from local assessment of the registration success. Furthermore, an atlas selection procedure is proposed that is equivalent to sequential forward selection from statistical pattern recognition theory. The proposed method is compared to three existing atlas-based segmentation approaches, namely 1) single atlas-based segmentation, 2) average-shape atlas-based segmentation, and 3) multi-atlas-based segmentation with averaging as decision fusion. These methods were tested on the segmentation of the heart and the aorta in computed tomography scans of the thorax. The results show that the proposed method outperforms other methods and yields results very close to those of an independent human observer. Moreover, the additional atlas selection step led to a faster segmentation at a comparable performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
David, F. N., & Tukey, J. W. (1977) · Biometrics · doi:10.2307/2529486 · Cited by 12,708
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Feature selection: evaluation, application, and small sample performance
Jain, A., & Zongker, D. (1997) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.574797 · Cited by 2,171
Osborn, J. F., & Tukey, J. W. (1978) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2344492 · Cited by 1,190
PET-CT image registration in the chest using free-form deformations
Mattes, D., Haynor, D. R., Vesselle, H., Lewellen, T. K., & Eubank, W. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.809072 · Cited by 871
Automatic anatomical brain MRI segmentation combining label propagation and decision fusion
Heckemann, R. A., Hajnal, J. V., Aljabar, P., Rueckert, D., & Hammers, A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.05.061 · Cited by 866
A Direct Method of Nonparametric Measurement Selection
Whitney, A. W. (1971) · IEEE Transactions on Computers · doi:10.1109/t-c.1971.223410 · Cited by 851
Optimization of mutual information for multiresolution image registration
Unser, M., & Thevenaz, P. (2000) · IEEE Transactions on Image Processing · doi:10.1109/83.887976 · Cited by 697
Rohlfing, T., Brandt, R., Menzel, R., & Maurer, C. R. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.010 · Cited by 573
Klein, S., Staring, M., & Pluim, J. P. W. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.909412 · Cited by 431
Self-citationFlorack, L. M. J. (1997) · Computational imaging and vision · doi:10.1007/978-94-015-8845-4 · Cited by 263
Three-dimensional average-shape atlas of the honeybee brain and its applications
Brandt, R., Rohlfing, T., Rybak, J., Krofczik, S., Maye, A., Westerhoff, M., Hege, H.-C., & Menzel, R. (2005) · The Journal of Comparative Neurology · doi:10.1002/cne.20644 · Cited by 251
Toward automated segmentation of the pathological lung in CT
Sluimer, I., Prokop, M., & van Ginneken, B. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.851757 · Cited by 237
Self-citationFlorack, L. M. J. (1997) · Cited by 219
Atlas-based hippocampus segmentation in Alzheimer's disease and mild cognitive impairment
Carmichael, O. T., Aizenstein, H. A., Davis, S. W., Becker, J. T., Thompson, P. M., Meltzer, C. C., & Liu, Y. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.05.005 · Cited by 208
Atlas-driven lung lobe segmentation in volumetric X-ray CT images
Zhang, L., Hoffman, E. A., & Reinhardt, J. M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.859209 · Cited by 200
Ascoli, G. A. (2002) · Humana Press eBooks · doi:10.1385/1592592759 · Cited by 192
Quo Vadis, Atlas-Based Segmentation?
Rohlfing, T., Brandt, R., Menzel, R., Russakoff, D. B., & Maurer, C. R. (2005) · Handbook of Biomedical Image Analysis · doi:10.1007/0-306-48608-3_11 · Cited by 183
Segmentation of brain 3D MR images using level sets and dense registration
Baillard, C., Pierre Hellier, J., & Barillot, C. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00039-1 · Cited by 142
Establishing a Normative Atlas of the Human Lung
Li, B., Christensen, G. E., Hoffman, E. A., McLennan, G., & Reinhardt, J. M. (2003) · Academic Radiology · doi:10.1016/s1076-6332(03)80099-5 · Cited by 137
Bondiau, P., Malandain, G., Chanalet, S., Marcy, P. Y., Habrand, J., Fauchon, F., Paquis, P., Courdi, A., Commowick, O., Rutten, I., et al. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.08.055 · Cited by 113
Išgum, I., Rutten, A., Prokop, M., & van Ginneken, B. (2007) · Medical Physics · doi:10.1118/1.2710548 · Cited by 106
Self-citationBee brains, B-splines and computational democracy: generating an average shape atlas
Torsten Rohlfing, B., Brandt, R., Maurer, C. R., & Menzel, R. (2002) · IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA) · doi:10.1109/mmbia.2001.991733 · Cited by 88
Adolf Pfefferbaum, A., Rosenbloom, M. J., Torsten Rohlfing, B., Elfar Adalsteinsson, A., Kemper, C. A., Deresinski, S. C., & Sullivan, E. V. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.05.052 · Cited by 77
Wu, M., Carmichael, O. T., López-García, P., Carter, C. S., & Aizenstein, H. J. (2006) · Human Brain Mapping · doi:10.1002/hbm.20216 · Cited by 74
Construction and evaluation of an average CT brain image for inter-subject registration
Jongen, C., Pluim, J. P. W., Nederkoorn, P. J., Viergever, M. A., & Niessen, W. J. (2003) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2003.10.003 · Cited by 17
Self-citationCastro, F. J. S., Pollo, C., Meuli, R. A., Maeder, P. P., Cuadra, M. B., Cuisenaire, O., Villemure, J., & Thiran, J. (2005) · Lecture notes in computer science · doi:10.1007/11566465_52 · Cited by 8
Cited by
Multi-Atlas Segmentation with Joint Label Fusion
Wang, H., Suh, J. W., Das, S. R., Pluta, J. B., Craige, C., & Yushkevich, P. A. (2013) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2012.143 · Cited by 796
“The inverse distance weighting has been applied as well [3], [17] 2 : w i ðxÞ ¼ 1 ZðxÞ X y2N ðxÞ F T ðyÞ À F i ðyÞ ð Þ 2 2 4 3 5 À ;”
Medical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
Multi-atlas segmentation of biomedical images: A survey
Iglesias, J. E., & Sabuncu, M. R. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.06.012 · Cited by 667
Multi-scale patch and multi-modality atlases for whole heart segmentation of MRI
Zhuang, X., & Shen, J. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.02.006 · Cited by 502
A Generative Model for Image Segmentation Based on Label Fusion
Sabuncu, M. R., Yeo, B. T. T., Van Leemput, K., Fischl, B., & Golland, P. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2050897 · Cited by 479
Metadata
- Authors
- Isgum, I., Staring, M., Rutten, A., Prokop, M., Viergever, M. A., & van Ginneken, B.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2009-07
- Volume
- 28
- Issue
- 7
- Pages
- 1000-1010
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2162140684
- Cited by
- 361
- References
- 27
- FWCI
- 26.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.