Nonlinear Regularization for Per Voxel Estimation of Magnetic Susceptibility Distributions From MRI Field Maps
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Magnetic susceptibility is an important physical property of tissues, and can be used as a contrast mechanism in magnetic resonance imaging (MRI). Recently, targeting contrast agents by conjugation with signaling molecules and labeling stem cells with contrast agents have become feasible. These contrast agents are strongly paramagnetic, and the ability to quantify magnetic susceptibility could allow accurate measurement of signaling and cell localization. Presented here is a technique to estimate arbitrary magnetic susceptibility distributions by solving an ill-posed inversion problem from field maps obtained in an MRI scanner. Two regularization strategies are considered: conventional Tikhonov regularization and a sparsity promoting nonlinear regularization using the l(1) norm. Proof of concept is demonstrated using numerical simulations, phantoms, and in a stroke model in a rat. Initial experience indicates that the nonlinear regularization better suppresses noise and streaking artifacts common in susceptibility estimation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Boyd, S., & Vandenberghe, L. (2004) · doi:10.1017/cbo9780511804441 · Cited by 56,601
(2020) · Electromagnetic Processes · doi:10.2307/j.ctv131bv37.5 · Cited by 21,966
Nonlinear total variation based noise removal algorithms
Rudin, L. I., Osher, S., & Fatemi, E. (1992) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(92)90242-f · Cited by 15,704 · cited 1×
“Total variation has been used in image denoising [ 48 ], and promotes sparsity of edges rather than sparsity of the estimated distribution, which may be a more realistic assumption.”
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639 · cited 1×
“The norm is also used by compressed sensing techniques [27], [28], and this application supplies the motivation for use of the norm for regularization of susceptibility inversion.”
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952 · cited 1×
“The l1 norm is also the driving force behind the compressed sensing techniques that have recently appeared in the information theory and MRI literature [25], [26].”
Discrete-time Signal Processing
Williamson, D. (1999) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0541-1 · Cited by 4,858
(1998) · Physics from Fisher Information · doi:10.1017/cbo9780511622670.006 · Cited by 4,018
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Modern Magnetic Materials: Principles and Applications
O’Handley, R. C. (1999) · Cited by 2,358
Cited by
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Self-citationSchweser, F., Deistung, A., Lehr, B. W., & Reichenbach, J. R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.070 · Cited by 710
de Rochefort, L., Liu, T., Kressler, B., Liu, J., Spincemaille, P., Lebon, V., Wu, J., & Wang, Y. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22187 · Cited by 670
Self-citationQuantitative susceptibility mapping of human brain reflects spatial variation in tissue composition
Li, W., Wu, B., & Liu, C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.088 · Cited by 624
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
MRI estimates of brain iron concentration in normal aging using quantitative susceptibility mapping
Bilgic, B., Pfefferbaum, A., Rohlfing, T., Sullivan, E. V., & Adalsteinsson, E. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.077 · Cited by 499
Liu, J., Liu, T., de Rochefort, L., Ledoux, J., Khalidov, I., Chen, W., Tsiouris, A. J., Wisnieff, C., Spincemaille, P., Prince, M. R., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.082 · Cited by 498
Self-citationA novel background field removal method for MRI using projection onto dipole fields (PDF)
Liu, T., Khalidov, I., de Rochefort, L., Spincemaille, P., Liu, J., Tsiouris, A. J., & Wang, Y. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1670 · Cited by 455
Self-citationLiu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Self-citationWhole brain susceptibility mapping using compressed sensing
Wu, B., Li, W., Guidon, A., & Liu, C. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23000 · Cited by 417
Liu, T., Liu, J., de Rochefort, L., Spincemaille, P., Khalidov, I., Ledoux, J. R., & Wang, Y. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22816 · Cited by 376
Self-citationLiu, T., Wisnieff, C., Lou, M., Chen, W., Spincemaille, P., & Wang, Y. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24272 · Cited by 360
Self-citationOverview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
A method for estimating and removing streaking artifacts in quantitative susceptibility mapping
Li, W., Wang, N., Yu, F., Han, H., Cao, W., Romero, R., Tantiwongkosi, B., Duong, T. Q., & Liu, C. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.043 · Cited by 337
Liu, C. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22482 · Cited by 325
Li, W., Avram, A. V., Wu, B., Xiao, X., & Liu, C. (2014) · NMR in Biomedicine · doi:10.1002/nbm.3056 · Cited by 308
Susceptibility mapping as a means to visualize veins and quantify oxygen saturation
Haacke, E. M., Tang, J., Neelavalli, J., & Cheng, Y. C. N. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22276 · Cited by 306
In Vivo Quantitative Susceptibility Mapping (QSM) in Alzheimer's Disease
Acosta-Cabronero, J., Williams, G. B., Cardenas-Blanco, A., Arnold, R. J., Lupson, V., & Nestor, P. J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0081093 · Cited by 287
In Vivo MRI Mapping of Brain Iron Deposition across the Adult Lifespan
Acosta-Cabronero, J., Betts, M. J., Cardenas-Blanco, A., Yang, S., & Nestor, P. J. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.1907-15.2016 · Cited by 274
Wang, Y., Spincemaille, P., Liu, Z., Dimov, A., Deh, K., Li, J., Zhang, Y., Yao, Y., Gillen, K. M., Wilman, A. H., et al. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25693 · Cited by 273
Self-citationBackground field removal by solving the Laplacian boundary value problem
Zhou, D., Liu, T., Spincemaille, P., & Wang, Y. (2014) · NMR in Biomedicine · doi:10.1002/nbm.3064 · Cited by 236
Self-citationWharton, S., & Bowtell, R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.070 · Cited by 187
“, 2010), regularisation of the inversion problem via the incorporation of prior knowledge of the form of the susceptibility distribution (Kressler et al., 2010; de Rochefort et al., 2010), and utilisation of a simple k-space threshold (Shmueli et al.”
InfluentialQuantitative oxygenation venography from MRI phase
Fan, A. P., Bilgic, B., Gagnon, L., Witzel, T., Bhat, H., Rosen, B. R., & Adalsteinsson, E. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24918 · Cited by 165
“Regularization is a mathematical technique to incorporate such prior information to solve an illposed problem, and several regularized approaches have been explored to reconstruct susceptibility maps from single-orientation field maps (21,32,33,45).”
Usefulness of Quantitative Susceptibility Mapping for the Diagnosis of Parkinson Disease
Murakami, Y., Kakeda, S., Watanabe, K., Ueda, I., Ogasawara, A., Moriya, J., Ide, S., Futatsuya, K., Sato, T., Okada, K., et al. (2015) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4260 · Cited by 162
“The Az value was 0.91 for QSM and 0.69 for R2*. Pair-wise comparisons showed that the Az for QSM was significantly larger than that for R2* (P .05).”
MethodInfluentialSelf-citation
Metadata
- Authors
- Kressler, B., de Rochefort, L., Liu, T., Spincemaille, P., Jiang, Q., & Wang, Y.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2010-02
- Volume
- 29
- Issue
- 2
- Pages
- 273-281
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W1972877268
- Cited by
- 220
- References
- 40
- FWCI
- 8.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.