The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
A method for estimating and removing streaking artifacts in quantitative susceptibility mapping
Open accessAbstract
Quantitative susceptibility mapping (QSM) is a novel MRI method for quantifying tissue magnetic property. In the brain, it reflects the molecular composition and microstructure of the local tissue. However, susceptibility maps reconstructed from single-orientation data still suffer from streaking artifacts which obscure structural details and small lesions. We propose and have developed a general method for estimating streaking artifacts and subtracting them from susceptibility maps. Specifically, this method uses a sparse linear equation and least-squares (LSQR)-algorithm-based method to derive an initial estimation of magnetic susceptibility, a fast quantitative susceptibility mapping method to estimate the susceptibility boundaries, and an iterative approach to estimate the susceptibility artifact from ill-conditioned k-space regions only. With a fixed set of parameters for the initial susceptibility estimation and subsequent streaking artifact estimation and removal, the method provides an unbiased estimate of tissue susceptibility with negligible streaking artifacts, as compared to multi-orientation QSM reconstruction. This method allows for improved delineation of white matter lesions in patients with multiple sclerosis and small structures of the human brain with excellent anatomical details. The proposed methodology can be extended to other existing QSM algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LSQR: An Algorithm for Sparse Linear Equations and Sparse Least Squares
Paige, C. C., & Saunders, M. A. (1982) · ACM Transactions on Mathematical Software · doi:10.1145/355984.355989 · Cited by 4,387
The effect of age on the non-haemin iron in the human brain
Hallgren, B., & Sourander, P. (1958) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1958.tb12607.x · Cited by 1,427
Langkammer, C., Schweser, F., Krebs, N., Deistung, A., Goessler, W., Scheurer, E., Sommer, K., Reishofer, G., Yen, K., Fazekas, F., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.049 · Cited by 801
Schweser, F., Deistung, A., Lehr, B. W., & Reichenbach, J. R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.070 · Cited by 710
de Rochefort, L., Liu, T., Kressler, B., Liu, J., Spincemaille, P., Lebon, V., Wu, J., & Wang, Y. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22187 · Cited by 670
High-field MRI of brain cortical substructure based on signal phase
Duyn, J. H., van Gelderen, P., Li, T.-Q., de Zwart, J. A., Koretsky, A. P., & Fukunaga, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610821104 · Cited by 641
Quantitative susceptibility mapping of human brain reflects spatial variation in tissue composition
Li, W., Wu, B., & Liu, C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.088 · Cited by 624
Self-citationMagnetic susceptibility mapping of brain tissue in vivo using MRI phase data
Shmueli, K., de Zwart, J. A., van Gelderen, P., Li, T., Dodd, S. J., & Duyn, J. H. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22135 · Cited by 527
Liu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Marques, J. P., & Bowtell, R. (2005) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.20034 · Cited by 434
Cited by
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
Wei, H., Dibb, R., Zhou, Y., Sun, Y., Xu, J., Wang, N., & Liu, C. (2015) · NMR in Biomedicine · doi:10.1002/nbm.3383 · Cited by 277
Self-citationQuantitative susceptibility mapping using deep neural network: QSMnet
Yoon, J., Gong, E., Chatnuntawech, I., Bilgic, B., Lee, J., Jung, W., Ko, J., Jung, H., Setsompop, K., Zaharchuk, G., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.06.030 · Cited by 185
Gong, N.-J., Dibb, R., Bulk, M., van der Weerd, L., & Liu, C. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.02.019 · Cited by 162
Self-citationCytoarchitecture of the mouse brain by high resolution diffusion magnetic resonance imaging
Wang, N., White, L. E., Qi, Y., Cofer, G., & Johnson, G. A. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116876 · Cited by 47
Self-citation
Metadata
- Authors
- Li, W., Wang, N., Yu, F., Han, H., Cao, W., Romero, R., Tantiwongkosi, B., Duong, T. Q., & Liu, C.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2015-03
- Volume
- 108
- Pages
- 111-122
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2168290350
- Cited by
- 337
- References
- 43
- FWCI
- 11.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A method for estimating and removing streaking artifacts in quantitative susceptibility mapping. https://app.cochat.ai/papers/10.1016/j.neuroimage.2014.12.043
- The paper
- Li, W., Wang, N., Yu, F., Han, H., Cao, W., Romero, R., Tantiwongkosi, B., Duong, T. Q., & Liu, C. (2015). A method for estimating and removing streaking artifacts in quantitative susceptibility mapping. NeuroImage. https://doi.org/10.1016/j.neuroimage.2014.12.043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.