The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Multiscale AM-FM Methods for Diabetic Retinopathy Lesion Detection
Open accessAbstract
In this paper, we propose the use of multiscale amplitude-modulation-frequency-modulation (AM-FM) methods for discriminating between normal and pathological retinal images. The method presented in this paper is tested using standard images from the early treatment diabetic retinopathy study. We use 120 regions of 40 x 40 pixels containing four types of lesions commonly associated with diabetic retinopathy (DR) and two types of normal retinal regions that were manually selected by a trained analyst. The region types included microaneurysms, exudates, neovascularization on the retina, hemorrhages, normal retinal background, and normal vessels patterns. The cumulative distribution functions of the instantaneous amplitude, the instantaneous frequency magnitude, and the relative instantaneous frequency angle from multiple scales are used as texture feature vectors. We use distance metrics between the extracted feature vectors to measure interstructure similarity. Our results demonstrate a statistical differentiation of normal retinal structures and pathological lesions based on AM-FM features. We further demonstrate our AM-FM methodology by applying it to classification of retinal images from the MESSIDOR database. Overall, the proposed methodology shows significant capability for use in automatic DR screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Walter, T., Klein, J., Massin, P., & Erginay, A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806290 · Cited by 825
Retinal Blood Vessel Segmentation Using Line Operators and Support Vector Classification
Ricci, E., & Perfetti, R. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.898551 · Cited by 818
Automatic detection of red lesions in digital color fundus photographs
Niemeijer, M., van Ginneken, B., Staal, J., Suttorp-Schulten, M. S. A., & Abramoff, M. D. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.843738 · Cited by 504
Self-citationNiemeijer, M., van Ginneken, B., Russell, S. R., Suttorp-Schulten, M. S. A., & Abra`moff, M. D. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0996 · Cited by 400
Self-citationOptimal Wavelet Transform for the Detection of Microaneurysms in Retina Photographs
Quellec, G., Lamard, M., Josselin, P. M., Cazuguel, G., Cochener, B., & Roux, C. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.920619 · Cited by 343
Retinal Vessel Centerline Extraction Using Multiscale Matched Filters, Confidence and Edge Measures
Sofka, M., & Stewart, C. V. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.884190 · Cited by 334
Spencer, T., Olson, J. A., McHardy, K. C., Sharp, P. F., & Forrester, J. V. (1996) · Computers and Biomedical Research · doi:10.1006/cbmr.1996.0021 · Cited by 305
An improved matched filter for blood vessel detection of digital retinal images
Al-Rawi, M., Qutaishat, M., & Arrar, M. (2007) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2006.03.003 · Cited by 305
Abràmoff, M. D., Niemeijer, M., Suttorp-Schulten, M. S. A., Viergever, M. A., Russell, S. R., & van Ginneken, B. (2008) · Diabetes Care · doi:10.2337/dc07-1312 · Cited by 277
Self-citationAutomated identification of diabetic retinal exudates in digital colour images
Osareh, A. (2003) · British Journal of Ophthalmology · doi:10.1136/bjo.87.10.1220 · Cited by 254
Philip, S., Fleming, A. D., Goatman, K. A., Fonseca, S., Mcnamee, P., Scotland, G. S., Prescott, G. J., Sharp, P. F., & Olson, J. A. (2007) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.119453 · Cited by 225
Frame, A. J., Undrill, P. E., Cree, M. J., Olson, J. A., McHardy, K. C., Sharp, P. F., & Forrester, J. V. (1998) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(98)00011-0 · Cited by 215
Automated Detection of Fundus Photographic Red Lesions in Diabetic Retinopathy
Larsen, M., Godt, J., Larsen, N. B., Lund‐Andersen, H., Sjølie, A. K., Agardh, E., Kalm, H., Grunkin, M., & Owens, D. R. (2003) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.02-0418 · Cited by 149
Classification and Localisation of Diabetic-Related Eye Disease
Osareh, A., Mirmehdi, M., Thomas, B., & Markham, R. (2002) · Lecture notes in computer science · doi:10.1007/3-540-47979-1_34 · Cited by 130
Retinal image analysis to detect and quantify lesions associated with diabetic retinopathy
Sánchez, C. I., Hornero, R., López, M. I., & Poza, J. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1403492 · Cited by 103
Automated detection and classification of vascular abnormalities in diabetic retinopathy
Vallabha, D., Dorairaj, R., Namuduri, K. R., & Thompson, H. W. (2005) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/acssc.2004.1399432 · Cited by 95
Multiscale AM-FM Demodulation and Image Reconstruction Methods With Improved Accuracy
Murray, V., Rodríguez, P., & Pattichis, M. S. (2010) · IEEE Transactions on Image Processing · doi:10.1109/tip.2010.2040446 · Cited by 90
Self-citationComputer Classification of Nonproliferative Diabetic Retinopathy
Lee, S. C. (2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.6.759 · Cited by 61
Analyzing Image Structure by Multidimensional Frequency Modulation
Pattichis, M. S., & Bovik, A. C. (2007) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2007.1051 · Cited by 61
Self-citationSopharak, A., & Uyyanonvara, B. (2007) · Cited by 36
Cited by
What do we need to build explainable AI systems for the medical domain?
Holzinger, A., Biemann, C., Pattichis, C. S., & Kell, D. B. (2017) · arXiv · doi:10.48550/arxiv.1712.09923 · Cited by 636
“The introduction of a multiscale approach in (Murray et al., 2010) demonstrated that the method can be used to reconstruct general images.”
BackgroundMethodComputer-aided diagnosis of diabetic retinopathy: A review
Mookiah, M. R. K., Acharya, U. R., Chua, C. K., Lim, C. M., Ng, E. Y. K., & Laude, A. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.10.007 · Cited by 430
DREAM: Diabetic Retinopathy Analysis Using Machine Learning
Roychowdhury, S., Koozekanani, D. D., & Parhi, K. K. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2294635 · Cited by 413
IDRiD: Diabetic Retinopathy – Segmentation and Grading Challenge
Porwal, P., Pachade, S., Kokare, M., Deshmukh, G., Son, J., Bae, W., Liu, L., Wang, J., Liu, X., Gao, L., et al. (2020) · Medical Image Analysis · doi:10.1016/j.media.2019.101561 · Cited by 372
Exudate-based diabetic macular edema detection in fundus images using publicly available datasets
Giancardo, L., Meriaudeau, F., Karnowski, T. P., Li, Y., Garg, S., Tobin, K. W., & Chaum, E. (2012) · Medical Image Analysis · doi:10.1016/j.media.2011.07.004 · Cited by 322
Metadata
- Authors
- Agurto, C., Murray, V., Barriga, E., Murillo, S., Pattichis, M., Davis, H., Russell, S., Abramoff, M., & Soliz, P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2010-02
- Volume
- 29
- Issue
- 2
- Pages
- 502-512
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2148989106
- Cited by
- 259
- References
- 21
- FWCI
- 12.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.