Three-Dimensional Analysis of Retinal Layer Texture: Identification of Fluid-Filled Regions in SD-OCT of the Macula
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Optical coherence tomography (OCT) is becoming one of the most important modalities for the noninvasive assessment of retinal eye diseases. As the number of acquired OCT volumes increases, automating the OCT image analysis is becoming increasingly relevant. In this paper, a method for automated characterization of the normal macular appearance in spectral domain OCT (SD-OCT) volumes is reported together with a general approach for local retinal abnormality detection. Ten intraretinal layers are first automatically segmented and the 3-D image dataset flattened to remove motion-based artifacts. From the flattened OCT data, 23 features are extracted in each layer locally to characterize texture and thickness properties across the macula. The normal ranges of layer-specific feature variations have been derived from 13 SD-OCT volumes depicting normal retinas. Abnormalities are then detected by classifying the local differences between the normal appearance and the retinal measures in question. This approach was applied to determine footprints of fluid-filled regions--SEADs (Symptomatic Exudate-Associated Derangements)--in 78 SD-OCT volumes from 23 repeatedly imaged patients with choroidal neovascularization (CNV), intra-, and sub-retinal fluid and pigment epithelial detachment. The automated SEAD footprint detection method was validated against an independent standard obtained using an interactive 3-D SEAD segmentation approach. An area under the receiver-operating characteristic curve of 0.961 +/- 0.012 was obtained for the classification of vertical, cross-layer, macular columns. A study performed on 12 pairs of OCT volumes obtained from the same eye on the same day shows that the repeatability of the automated method is comparable to that of the human experts. This work demonstrates that useful 3-D textural information can be extracted from SD-OCT scans and--together with an anatomical atlas of normal retinas--can be used for clinically important applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Interactive graph cuts for optimal boundary & region segmentation of objects in N-D images
Boykov, Y. Y., & Jolly, M.-P. (2002) · Proceedings Eighth IEEE International Conference on Computer Vision. ICCV 2001 · doi:10.1109/iccv.2001.937505 · Cited by 3,674
(1993) · Archives of Ophthalmology · doi:10.1001/archopht.1993.01090090052019 · Cited by 303
Cited by
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Self-citationMwanza, J.-C., Oakley, J. D., Budenz, D. L., Chang, R. T., Knight, O. J., & Feuer, W. J. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-7962 · Cited by 429
Chiu, S. J., Allingham, M. J., Mettu, P. S., Cousins, S. W., Izatt, J. A., & Farsiu, S. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001172 · Cited by 377
Macular OCT Classification Using a Multi-Scale Convolutional Neural Network Ensemble
Rasti, R., Rabbani, H., Mehridehnavi, A., & Hajizadeh, F. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2780115 · Cited by 298
Automated layer segmentation of macular OCT images using dual-scale gradient information
Yang, Q., Reisman, C. A., Wang, Z., Fukuma, Y., Hangai, M., Yoshimura, N., Tomidokoro, A., Araie, M., Raza, A. S., Hood, D. C., et al. (2010) · Optics Express · doi:10.1364/oe.18.021293 · Cited by 284
RETOUCH: The Retinal OCT Fluid Detection and Segmentation Benchmark and Challenge
Bogunovic, H., Venhuizen, F., Klimscha, S., Apostolopoulos, S., Bab-Hadiashar, A., Bagci, U., Beg, M. F., Bekalo, L., Chen, Q., Ciller, C., et al. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2901398 · Cited by 273
Three-dimensional solid texture analysis in biomedical imaging: Review and opportunities
Depeursinge, A., Foncubierta-Rodriguez, A., Van De Ville, D., & Müller, H. (2014) · Medical Image Analysis · doi:10.1016/j.media.2013.10.005 · Cited by 244
“and Yoshida (2009); Sandfort and Ohser (2009)) was used for 3–D medical texture characterization in Paulhac et al.”
MethodChen, X., Niemeijer, M., Zhang, L., Lee, K., Abramoff, M. D., & Sonka, M. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2191302 · Cited by 196
“An automatic voxel classification-based initialization is utilized that is based on the layer-specific texture features following the success of our previous work [12], [19].”
BackgroundMethodInfluentialSelf-citationLiu, Y.-Y., Chen, M., Ishikawa, H., Wollstein, G., Schuman, J. S., & Rehg, J. M. (2011) · Medical Image Analysis · doi:10.1016/j.media.2011.06.005 · Cited by 183
“Note that our procedure fits and warps the entire retina rather than segmenting a particular retinal layer first (e.g. the RPE layer) and then performing flattening using that layer (Quellec et al., 2010).”
BackgroundMethodKafieh, R., Rabbani, H., Abramoff, M. D., & Sonka, M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.05.006 · Cited by 160
Self-citation
Metadata
- Authors
- Quellec, G., Lee, K., Dolejsi, M., Garvin, M. K., Abramoff, M. D., & Sonka, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2010-06
- Volume
- 29
- Issue
- 6
- Pages
- 1321-1330
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2122333898
- Cited by
- 214
- References
- 3
- FWCI
- 8.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.