Nonrigid 2D/3D Registration of Coronary Artery Models With Live Fluoroscopy for Guidance of Cardiac Interventions
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
A 2D/3D nonrigid registration method is proposed that brings a 3D centerline model of the coronary arteries into correspondence with bi-plane fluoroscopic angiograms. The registered model is overlaid on top of interventional angiograms to provide surgical assistance during image-guided chronic total occlusion procedures, thereby reducing the uncertainty inherent in 2D interventional images. The proposed methodology is divided into two parts: global structural alignment and local nonrigid registration. In both cases, vessel centerlines are automatically extracted from the 2D fluoroscopic images, and serve as the basis for the alignment and registration algorithms. In the first part, an energy minimization method is used to estimate a global affine transformation that aligns the centerline with the angiograms. The performance of nine general purpose optimizers has been assessed for this problem, and detailed results are presented. In the second part, a fully nonrigid registration method is proposed and used to compensate for any local shape discrepancy. This method is based on a variational framework, and uses a simultaneous matching and reconstruction process to compute a nonrigid registration. With a typical run time of less than 3 s, the algorithms are fast enough for interactive applications. Experiments on five different subjects are presented and show promising results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Powell, M. J. D. (1964) · The Computer Journal · doi:10.1093/comjnl/7.2.155 · Cited by 4,632
Powell, M. J. D. (1994) · Advances in Optimization and Numerical Analysis · doi:10.1007/978-94-015-8330-5_4 · Cited by 1,369
Log-Euclidean metrics for fast and simple calculus on diffusion tensors
Arsigny, V., Fillard, P., Pennec, X., & Ayache, N. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20965 · Cited by 1,113
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746 · cited 1×
“[22].”
Handbook of Mathematical Models in Computer Vision
(2006) · doi:10.1007/0-387-28831-7 · Cited by 574
Deformable 2D-3D Registration of Vascular Structures in a One View Scenario
Groher, M., Zikic, D., & Navab, N. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2011519 · Cited by 91
van der Bom, I. M. J., Klein, S., Staring, M., Homan, R., Bartels, L. W., & Pluim, J. P. W. (2011) · SPIE Proceedings · doi:10.1117/12.877655 · Cited by 55
(2009) · doi:10.1007/978-3-642-04268-3_46 · Cited by 32
Accurate and precise 2D–3D registration based on X-ray intensity
Aouadi, S., & Sarry, L. (2008) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2007.05.006 · Cited by 30 · cited 1×
“Such formulations have less computational complexity than those based on point matching approaches [40], [43] or on digitally reconstructed radiographs [33], [39].”
Background
Cited by
Fiber Optic Shape Sensors: A comprehensive review
Floris, I., Adam, J. M., Calderón, P. A., & Sales, S. (2021) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106508 · Cited by 316
Otake, Y., Wang, A. S., Webster Stayman, J., Uneri, A., Kleinszig, G., Vogt, S., Khanna, A. J., Gokaslan, Z. L., & Siewerdsen, J. H. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/23/8535 · Cited by 89
“…et al 2012), real-time kinematic analysis of skeletal movements using fluoroscopy (Xin et al 2013, Zhu et al 2012, Jerbi et al 2012), guidance of various surgical interventions such as cardiac surgery (Rivest-Henault et al 2012), and transrectal ultrasound guided surgery (De Silva et al 2013).”
BackgroundMethod3D-2D Registration of Cerebral Angiograms: A Method and Evaluation on Clinical Images
Mitrovic, U., Spiclin, Z., Likar, B., & Pernus, F. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2259844 · Cited by 67
“There were about 14 000 centerline points per 2D image for which the distance transform was precomputed so as to speed up the nearest neighbor search to the projected 3D centerline points [20].”
InfluentialIterative Closest Graph Matching for Non-rigid 3d/2d Coronary Arteries Registration
Zhu, J., Li, H., Ai, D., Yang, Q., Fan, J., Huang, Y., Song, H., Han, Y., & Yang, J. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105901 · Cited by 22
Metadata
- Authors
- Rivest-Henault, D., Sundar, H., & Cheriet, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2012-08
- Volume
- 31
- Issue
- 8
- Pages
- 1557-1572
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2014748826
- Cited by
- 76
- References
- 9
- FWCI
- 7.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.