Superpixel Classification Based Optic Disc and Optic Cup Segmentation for Glaucoma Screening
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Glaucoma is a chronic eye disease that leads to vision loss. As it cannot be cured, detecting the disease in time is important. Current tests using intraocular pressure (IOP) are not sensitive enough for population based glaucoma screening. Optic nerve head assessment in retinal fundus images is both more promising and superior. This paper proposes optic disc and optic cup segmentation using superpixel classification for glaucoma screening. In optic disc segmentation, histograms, and center surround statistics are used to classify each superpixel as disc or non-disc. A self-assessment reliability score is computed to evaluate the quality of the automated optic disc segmentation. For optic cup segmentation, in addition to the histograms and center surround statistics, the location information is also included into the feature space to boost the performance. The proposed segmentation methods have been evaluated in a database of 650 images with optic disc and optic cup boundaries manually marked by trained professionals. Experimental results show an average overlapping error of 9.5% and 24.1% in optic disc and optic cup segmentation, respectively. The results also show an increase in overlapping error as the reliability score is reduced, which justifies the effectiveness of the self-assessment. The segmented optic disc and optic cup are then used to compute the cup to disc ratio for glaucoma screening. Our proposed method achieves areas under curve of 0.800 and 0.822 in two data sets, which is higher than other methods. The methods can be used for segmentation and glaucoma screening. The self-assessment will be used as an indicator of cases with large errors and enhance the clinical deployment of the automatic segmentation and screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Mean shift: a robust approach toward feature space analysis
Comaniciu, D., & Meer, P. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.1000236 · Cited by 11,305
A model of saliency-based visual attention for rapid scene analysis
Itti, L., Koch, C., & Niebur, E. (1998) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.730558 · Cited by 11,271
Libsvm : A library for support vector machines
Ferrari, V. (2008) · Medical Entomology and Zoology · Cited by 10,123
SLIC Superpixels Compared to State-of-the-Art Superpixel Methods
Achanta, R., Shaji, A., Smith, K., Lucchi, A., Fua, P., & Süsstrunk, S. (2012) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2012.120 · Cited by 9,201
The number of people with glaucoma worldwide in 2010 and 2020
Quigley, H. A. (2006) · British Journal of Ophthalmology · doi:10.1136/bjo.2005.081224 · Cited by 7,394
Efficient Graph-Based Image Segmentation
Felzenszwalb, P. F., & Huttenlocher, D. P. (2004) · International Journal of Computer Vision · doi:10.1023/b:visi.0000022288.19776.77 · Cited by 6,176
Watersheds in digital spaces: an efficient algorithm based on immersion simulations
Vincent, L., & Soille, P. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.87344 · Cited by 5,649
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Direct least square fitting of ellipses
Fitzgibbon, A., Pilu, M., & Fisher, R. B. (1999) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.765658 · Cited by 2,752
Cited by
CE-Net: Context Encoder Network for 2D Medical Image Segmentation
Gu, Z., Cheng, J., Fu, H., Zhou, K., Hao, H., Zhao, Y., Zhang, T., Gao, S., & Liu, J. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2903562 · Cited by 2,267
Self-citationMedical image segmentation using deep learning: A survey
Wang, R., Lei, T., Cui, R., Zhang, B., Meng, H., & Nandi, A. K. (2022) · IET Image Processing · doi:10.1049/ipr2.12419 · Cited by 892
Joint Optic Disc and Cup Segmentation Based on Multi-Label Deep Network and Polar Transformation
Fu, H., Cheng, J., Xu, Y., Wong, D. W. K., Liu, J., & Cao, X. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2791488 · Cited by 834
Self-citationTransformation-Consistent Self-Ensembling Model for Semisupervised Medical Image Segmentation
Li, X., Yu, L., Chen, H., Fu, C.-W., Xing, L., & Heng, P.-A. (2021) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2020.2995319 · Cited by 543
CNNs for automatic glaucoma assessment using fundus images: an extensive validation
Diaz-Pinto, A., Morales, S., Naranjo, V., Köhler, T., Mossi, J. M., & Navea, A. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0649-y · Cited by 435
Disc-Aware Ensemble Network for Glaucoma Screening From Fundus Image
Fu, H., Cheng, J., Xu, Y., Zhang, C., Wong, D. W. K., Liu, J., & Cao, X. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2837012 · Cited by 394
Self-citationReal-Time Superpixel Segmentation by DBSCAN Clustering Algorithm
Shen, J., Hao, X., Liang, Z., Liu, Y., Wang, W., & Shao, L. (2016) · IEEE Transactions on Image Processing · doi:10.1109/tip.2016.2616302 · Cited by 384
Zilly, J., Buhmann, J. M., & Mahapatra, D. (2017) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2016.07.012 · Cited by 372
A Large-Scale Database and a CNN Model for Attention-Based Glaucoma Detection
Li, L., Xu, M., Liu, H., Li, Y., Wang, X., Jiang, L., Wang, Z., Fan, X., & Wang, N. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2927226 · Cited by 303
Patch-Based Output Space Adversarial Learning for Joint Optic Disc and Cup Segmentation
Wang, S., Yu, L., Yang, X., Fu, C.-W., & Heng, P.-A. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2899910 · Cited by 293
Singh, A., Dutta, M. K., ParthaSarathi, M., Uher, V., & Burget, R. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.10.010 · Cited by 211
“[16] Fundus image 1 feature cup to disk ratio considered Not used Not used Not used Not Reported Local data base”
MethodWang, S., Yu, L., Li, K., Yang, X., Fu, C.-W., & Heng, P.-A. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3015224 · Cited by 204
Superpixel segmentation: A benchmark
Wang, M., Liu, X., Gao, Y., Ma, X., & Soomro, N. Q. (2017) · Signal Processing: Image Communication · doi:10.1016/j.image.2017.04.007 · Cited by 179
(2018) · doi:10.1117/12.2293584 · Cited by 171
Rotation-Oriented Collaborative Self-Supervised Learning for Retinal Disease Diagnosis
Li, X., Hu, X., Qi, X., Yu, L., Zhao, W., Heng, P.-A., & Xing, L. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3075244 · Cited by 105
Metadata
- Authors
- Cheng, J., Liu, J., Xu, Y., Yin, F., Wong, D. W. K., Tan, N.-M., Tao, D., Cheng, C.-Y., Aung, T., & Wong, T. Y.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2013-06
- Volume
- 32
- Issue
- 6
- Pages
- 1019-1032
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2081178133
- Cited by
- 593
- References
- 41
- FWCI
- 22.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.