Quantitative Comparison of Reconstruction Methods for Intra-Voxel Fiber Recovery From Diffusion MRI
Open accessThe DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Abstract
Validation is arguably the bottleneck in the diffusion magnetic resonance imaging (MRI) community. This paper evaluates and compares 20 algorithms for recovering the local intra-voxel fiber structure from diffusion MRI data and is based on the results of the "HARDI reconstruction challenge" organized in the context of the "ISBI 2012" conference. Evaluated methods encompass a mixture of classical techniques well known in the literature such as diffusion tensor, Q-Ball and diffusion spectrum imaging, algorithms inspired by the recent theory of compressed sensing and also brand new approaches proposed for the first time at this contest. To quantitatively compare the methods under controlled conditions, two datasets with known ground-truth were synthetically generated and two main criteria were used to evaluate the quality of the reconstructions in every voxel: correct assessment of the number of fiber populations and angular accuracy in their orientation. This comparative study investigates the behavior of every algorithm with varying experimental conditions and highlights strengths and weaknesses of each approach. This information can be useful not only for enhancing current algorithms and develop the next generation of reconstruction methods, but also to assist physicians in the choice of the most adequate technique for their studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,591
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Characterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
Tournier, J.-D., Calamante, F., & Connelly, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.016 · Cited by 2,188
Tuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
Tracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774
Cited by
Tractography-based connectomes are dominated by false-positive connections
Maier-Hein, K. H., Neher, P., Houde, J.-C., Côté, M.-A., Garyfallidis, E., Zhong, J., Chamberland, M., Yeh, F.-C., Lin, Y.-C., Ji, Q., et al. (2016) · doi:10.1101/084137 · Cited by 1,376
Self-citationAccelerated microstructure imaging via Convex Optimization (AMICO) from diffusion MRI data
Daducci, A., Canales-Rodríguez, E. J., Zhang, H., Dyrby, T. B., Alexander, D. C., & Thiran, J.-P. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.10.026 · Cited by 593
Self-citationDiffusion MRI fiber tractography of the brain
Jeurissen, B., Descoteaux, M., Mori, S., & Leemans, A. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3785 · Cited by 666
“On the same data, however, they are unlikely to outperform fODF tracking approaches.(95,98,99) For a more in‐depth discussion of the dODF in relation to the fiber orientation estimation, the reader is referred to Reference 3.”
BackgroundSelf-citationWhy rankings of biomedical image analysis competitions should be interpreted with care
Maier-Hein, L., Eisenmann, M., Reinke, A., Onogur, S., Stankovic, M., Scholz, P., Arbel, T., Bogunovic, H., Bradley, A. P., Carass, A., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-07619-7 · Cited by 380
Limits to anatomical accuracy of diffusion tractography using modern approaches
Schilling, K. G., Nath, V., Hansen, C., Parvathaneni, P., Blaber, J., Gao, Y., Neher, P., Aydogan, D. B., Shi, Y., Ocampo-Pineda, M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.10.029 · Cited by 260
“Past diffusion MRI challenges have utilized similar frameworks to assess reproducibility of tractography and fiber orientation reconstruction (Daducci et al., 2014).”
BackgroundMethodSelf-citationCOMMIT: Convex Optimization Modeling for Microstructure Informed Tractography
Daducci, A., Dal Palu, A., Lemkaddem, A., & Thiran, J.-P. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2352414 · Cited by 255
“To date, the effects of under-sampled data have been widely investigated, using the theory of compressed sensing [32], [33], for diffusion modeling at the voxel level (see [44] and references therein).”
MethodSelf-citationHistological validation of diffusion MRI fiber orientation distributions and dispersion
Schilling, K. G., Janve, V., Gao, Y., Stepniewska, I., Landman, B. A., & Anderson, A. W. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.046 · Cited by 195
Schilling, K. G., Rheault, F., Petit, L., Hansen, C. B., Nath, V., Yeh, F.-C., Girard, G., Barakovic, M., Rafael-Patino, J., Yu, T., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118502 · Cited by 182
Self-citationMapping connectomes with diffusion MRI: deterministic or probabilistic tractography?
Sarwar, T., Ramamohanarao, K., & Zalesky, A. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27471 · Cited by 182
Challenges for biophysical modeling of microstructure
Jelescu, I. O., Palombo, M., Bagnato, F., & Schilling, K. G. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108861 · Cited by 160
“There still exist di ff erences in resolvable crossing angles, angular accuracy, and successes in identifying fi ber populations, but there was no “ optimal ” method for a given acquisition, none out-performed others in every evaluation criteria (Daducci et al., 2014).”
MethodInfluentialCivier, O., Smith, R. E., Yeh, C.-H., Connelly, A., & Calamante, F. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.02.039 · Cited by 95
Tractography and machine learning: current state and open challenges
Poulin, P., Jörgens, D., Jodoin, P.-M., & Descoteaux, M. (2019) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2019.04.013 · Cited by 84
“HARDI Reconstruction challenge (2013) The 2013 HARDI Reconstruction Challenge [47] was organized one year later at the ISBI 2013 conference.”
MethodInfluentialSelf-citationYang, J. Y.-M., Yeh, C.-H., Poupon, C., & Calamante, F. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ac0d90 · Cited by 80
Schilling, K. G., Archer, D., Yeh, F.-C., Rheault, F., Cai, L. Y., Hansen, C., Yang, Q., Ramdass, K., Shafer, A. T., Resnick, S. M., et al. (2022) · Brain Structure and Function · doi:10.1007/s00429-022-02503-z · Cited by 78
“In particular, the CAM–CAM shows the largest differences, likely due to the use of a multi-shell acquisition, and its effects on local reconstruction algorithms (Schilling et al. 2018; Daducci et al. 2014; Fillard et al. 2011).”
BackgroundSt-Jean, S., Coupé, P., & Descoteaux, M. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.02.010 · Cited by 74
Self-citationLemkaddem, A., Daducci, A., Kunz, N., Lazeyras, F., Seeck, M., Thiran, J.-P., & Vulliémoz, S. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.07.013 · Cited by 70
“A recent review comparing different methods showed that other HARDI protocols can be used to obtain the same angular resolution in a shorter time (Daducci et al., 2014).”
MethodSelf-citationAssessment of white matter microstructure in stroke patients using NODDI
Adluru, G., Gur, Y., Anderson, J. S., Richards, L. G., Adluru, N., & DiBella, E. V. R. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6943697 · Cited by 69
Self-citationFiber tractography using machine learning
Neher, P. F., Côté, M.-A., Houde, J.-C., Descoteaux, M., & Maier-Hein, K. H. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.028 · Cited by 68
Self-citationPredicting motor outcomes in stroke patients using diffusion Spectrum mri microstructural measures
Hodgson, K., Adluru, G., Richards, L. G., Majersik, J. J., Stoddard, G., Adluru, N., & DiBella, E. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00072 · Cited by 36
Reproducibility of the structural connectome reconstruction across diffusion methods
Prčkovska, V., Rodrigues, P., Puigdellivol Sanchez, A., Ramos, M., Andorra, M., Martinez‐Heras, E., Falcon, C., Prats‐Galino, A., & Villoslada, P. (2016) · Journal of Neuroimaging · doi:10.1111/jon.12298 · Cited by 24
“First, we assessed the variability of the connectome constructed from data acquired in the same imaging session, as well as 1 month later constructed with different acquisitions schemes (DTI, HARDI, and DSI) and at different scales of parcellation (33-500).”
MethodSelf-citation
Metadata
- Authors
- Daducci, A., Canales-Rodriguez, E. J., Descoteaux, M., Garyfallidis, E., Gur, Y., Lin, Y.-C., Mani, M., Merlet, S., Paquette, M., Ramirez-Manzanares, A., Reisert, M., Rodrigues, P. R., Sepehrband, F., Caruyer, E., Choupan, J., Deriche, R., Jacob, M., Menegaz, G., Prckovska, V., Rivera, M., Wiaux, Y., & Thiran, J.-P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2014-02
- Volume
- 33
- Issue
- 2
- Pages
- 384-399
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2021228864
- Cited by
- 172
- References
- 71
- FWCI
- 10.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.