Quantitative Comparison of Reconstruction Methods for Intra-Voxel Fiber Recovery From Diffusion MRI
Open accessThe DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Abstract
Validation is arguably the bottleneck in the diffusion magnetic resonance imaging (MRI) community. This paper evaluates and compares 20 algorithms for recovering the local intra-voxel fiber structure from diffusion MRI data and is based on the results of the "HARDI reconstruction challenge" organized in the context of the "ISBI 2012" conference. Evaluated methods encompass a mixture of classical techniques well known in the literature such as diffusion tensor, Q-Ball and diffusion spectrum imaging, algorithms inspired by the recent theory of compressed sensing and also brand new approaches proposed for the first time at this contest. To quantitatively compare the methods under controlled conditions, two datasets with known ground-truth were synthetically generated and two main criteria were used to evaluate the quality of the reconstructions in every voxel: correct assessment of the number of fiber populations and angular accuracy in their orientation. This comparative study investigates the behavior of every algorithm with varying experimental conditions and highlights strengths and weaknesses of each approach. This information can be useful not only for enhancing current algorithms and develop the next generation of reconstruction methods, but also to assist physicians in the choice of the most adequate technique for their studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,591
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Characterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
Tournier, J.-D., Calamante, F., & Connelly, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.016 · Cited by 2,188
Tuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
Tracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774
Tournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635
High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548
MRtrix: Diffusion tractography in crossing fiber regions
Tournier, J., Calamante, F., & Connelly, A. (2012) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22005 · Cited by 1,370
Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging
Wedeen, V. J., Hagmann, P., Tseng, W. I., Reese, T. G., & Weisskoff, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20642 · Cited by 1,339
Schmahmann, J. D., Pandya, D. N., Wang, R., Dai, G., D'Arceuil, H. E., de Crespigny, A. J., & Wedeen, V. J. (2007) · Brain · doi:10.1093/brain/awl359 · Cited by 1,067
Generalized ${ q}$-Sampling Imaging
Yeh, F.-C., Wedeen, V. J., & Tseng, W.-Y. I. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2045126 · Cited by 1,019
Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain
Assaf, Y., & Basser, P. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.042 · Cited by 856
Regularized, fast, and robust analytical Q-ball imaging
Descoteaux, M., Angelino, E., Fitzgibbons, S., & Deriche, R. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21277 · Cited by 850
Self-citationDeterministic and probabilistic tractography based on complex fibre orientation distributions
Descoteaux, M., Deriche, R., Knosche, T. R., & Anwander, A. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2004424 · Cited by 698
Self-citation(2009) · doi:10.1016/b978-0-12-374709-9.x0001-6 · Cited by 686
Diffraction-like effects in NMR diffusion studies of fluids in porous solids
Callaghan, P. T., Coy, A., MacGowan, D., Packer, K. J., & Zelaya, F. O. (1991) · Nature · doi:10.1038/351467a0 · Cited by 649
Tournier, J.-D., Yeh, C.-H., Calamante, F., Cho, K.-H., Connelly, A., & Lin, C.-P. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.05.002 · Cited by 593
Detection and modeling of non‐Gaussian apparent diffusion coefficient profiles in human brain data
Alexander, D. C., Barker, G. J., & Arridge, S. R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10209 · Cited by 528
Compartment models of the diffusion MR signal in brain white matter: A taxonomy and comparison
Panagiotaki, E., Schneider, T., Siow, B., Hall, M. G., Lythgoe, M. F., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.081 · Cited by 422
Quantitative evaluation of 10 tractography algorithms on a realistic diffusion MR phantom
Fillard, P., Descoteaux, M., Goh, A., Gouttard, S., Jeurissen, B., Malcolm, J., Ramirez-Manzanares, A., Reisert, M., Sakaie, K., Tensaouti, F., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.032 · Cited by 418
Self-citationResolution of complex tissue microarchitecture using the diffusion orientation transform (DOT)
Özarslan, E., Shepherd, T. M., Vemuri, B. C., Blackband, S. J., & Mareci, T. H. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.024 · Cited by 388
Aganj, I., Lenglet, C., Sapiro, G., Yacoub, E., Ugurbil, K., & Harel, N. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22365 · Cited by 365
Persistent angular structure: new insights from diffusion magnetic resonance imaging data
Jansons, K. M., & Alexander, D. C. (2003) · Inverse Problems · doi:10.1088/0266-5611/19/5/303 · Cited by 304
Dell'Acqua, F., Scifo, P., Rizzo, G., Catani, M., Simmons, A., Scotti, G., & Fazio, F. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.033 · Cited by 304
Lin, C.-P., Wedeen, V. J., Chen, J.-H., Yao, C., & Tseng, W.-Y. I. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00154-x · Cited by 225
Jian, B., & Vemuri, B. C. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.907552 · Cited by 201
Axer, M., Grässel, D., Kleiner, M., Dammers, J., Dickscheid, T., Reckfort, J., Hütz, T., Eiben, B., Pietrzyk, U., Zilles, K., et al. (2011) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2011.00034 · Cited by 198
Poupon, C., Rieul, B., Kezele, I., Perrin, M., Poupon, F., & Mangin, J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21789 · Cited by 197
A Model-Based Deconvolution Approach to Solve Fiber Crossing in Diffusion-Weighted MR Imaging
Dell'Acqua, F., Rizzo, G., Scifo, P., Clarke, R. A., Scotti, G., & Fazio, F. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.888830 · Cited by 194
Wu, Y.-C., & Alexander, A. L. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.050 · Cited by 191
Sotiropoulos, S. N., Moeller, S., Jbabdi, S., Xu, J., Andersson, J. L., Auerbach, E. J., Yacoub, E., Feinberg, D., Setsompop, K., Wald, L. L., et al. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24623 · Cited by 186
Leergaard, T. B., White, N. S., de Crespigny, A., Bolstad, I., D'Arceuil, H., Bjaalie, J. G., & Dale, A. M. (2010) · PLoS ONE · doi:10.1371/journal.pone.0008595 · Cited by 179
Maximum Entropy Spherical Deconvolution for Diffusion MRI
Alexander, D. C. (2005) · Lecture notes in computer science · doi:10.1007/11505730_7 · Cited by 153
Spatially Regularized Compressed Sensing for High Angular Resolution Diffusion Imaging
Michailovich, O., Rathi, Y., & Dolui, S. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2142189 · Cited by 149
Estimating Crossing Fibers: A Tensor Decomposition Approach
Schultz, T., & Seidel, H.-P. (2008) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/tvcg.2008.128 · Cited by 137
Regularized positive-definite fourth order tensor field estimation from DW-MRI
Barmpoutis, A., Hwang, M. S., Howland, D. R., Forder, J. R., & Vemuri, B. C. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.056 · Cited by 133
Restricted Diffusion in Cylindrical Geometry
Söderman, O., & Jönsson, B. T. L. (1995) · Journal of Magnetic Resonance Series A · doi:10.1006/jmra.1995.0014 · Cited by 126
Resolution of crossing fibers with constrained compressed sensing using diffusion tensor MRI
Landman, B. A., Bogovic, J. A., Wan, H., ElShahaby, F. E. Z., Bazin, P.-L., & Prince, J. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.011 · Cited by 124
Recent advances in diffusion MRI modeling: Angular and radial reconstruction
Assemlal, H.-E., Tschumperlé, D., Brun, L., & Siddiqi, K. (2011) · Medical Image Analysis · doi:10.1016/j.media.2011.02.002 · Cited by 122
Multitensor approach for analysis and tracking of complex fiber configurations
Kreher, B. W., Schneider, J. F., Mader, I., Martin, E., Hennig, J., & Il'yasov, K. A. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20670 · Cited by 119
Tristán‐Vega, A., Westin, C., & Aja‐Fernández, S. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.04.049 · Cited by 117
Diffusion Basis Functions Decomposition for Estimating White Matter Intravoxel Fiber Geometry
Ramirez-Manzanares, A., Rivera, M., Vemuri, B. C., Carney, P., & Mareci, T. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.900461 · Cited by 116
Self-citationHistological Validation of DW-MRI Tractography in Human Postmortem Tissue
Seehaus, A. K., Roebroeck, A., Chiry, O., Kim, D.-S., Ronen, I., Bratzke, H., Goebel, R., & Galuske, R. A. W. (2013) · Cerebral Cortex · doi:10.1093/cercor/bhs036 · Cited by 109
Fritzsche, K. H., Laun, F. B., Meinzer, H.-P., & Stieltjes, B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.007 · Cited by 82
Mathematical description of q‐space in spherical coordinates: Exact q‐ball imaging
Canales‐Rodríguez, E. J., Melie‐García, L., & Iturria‐Medina, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21917 · Cited by 75
Ground truth hardware phantoms for validation of diffusion‐weighted MRI applications
Pullens, P., Roebroeck, A., & Goebel, R. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22243 · Cited by 71
Sparse Multi-Shell Diffusion Imaging
Rathi, Y., Michailovich, O., Setsompop, K., Bouix, S., Shenton, M. E., & Westin, C. F. (2011) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-23629-7_8 · Cited by 56
Laun, F. B., Huff, S., & Stieltjes, B. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.08.011 · Cited by 46
Novel spherical phantoms for Q‐ball imaging under in vivo conditions
Moussavi‐Biugui, A., Stieltjes, B., Fritzsche, K., Semmler, W., & Laun, F. B. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22602 · Cited by 45
Deconvolution in diffusion spectrum imaging
Canales-Rodríguez, E. J., Iturria‐Medina, Y., Alemán‐Gómez, Y., & Melie‐García, L. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.066 · Cited by 41
Coaxially Electrospun Axon-Mimicking Fibers for Diffusion Magnetic Resonance Imaging
Zhou, F., Cristinacce, P. L. H., Eichhorn, S. J., & Parker, G. J. M. (2012) · ACS Applied Materials & Interfaces · doi:10.1021/am301919s · Cited by 41
Probabilistic ODF Estimation from Reduced HARDI Data with Sparse Regularization
Tristán‐Vega, A., & Westin, C. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-23629-7_23 · Cited by 39
A review on statistical noise models for Magnetic Resonance Imaging 1
Aja‐Fernández, S., & Trist, A. (2013) · Cited by 39
Parametric Dictionary Learning for Modeling EAP and ODF in Diffusion MRI
Merlet, S., Caruyer, E., & Rachid Deriche, B. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-33454-2_2 · Cited by 36
Self-citationDiffusion orientation transform revisited
Canales-Rodríguez, E. J., Lin, C., Iturria‐Medina, Y., Yeh, C., Cho, K.-H., & Melie‐García, L. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.067 · Cited by 34
Advanced fit of the diffusion kurtosis tensor by directional weighting and regularization
Kuder, T. A., Stieltjes, B., Bachert, P., Semmler, W., & Laun, F. B. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23133 · Cited by 34
Investigation of resolution effects using a specialized diffusion tensor phantom
Bach, M., Fritzsche, K. H., Stieltjes, B., & Laun, F. B. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24774 · Cited by 32
Haldar, J. P., & Leahy, R. M. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.01.022 · Cited by 27
Melie‐García, L., Canales-Rodríguez, E. J., Alemán‐Gómez, Y., Lin, C., Iturria‐Medina, Y., & Valdes-Hernandez, P. A. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.04.242 · Cited by 25
Spherical wavelet transform for ODF sharpening
Kezele, I., Descoteaux, M., Poupon, C., Poupon, F., & Mangin, J.-F. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.01.002 · Cited by 23 · cited 3×
“Imaging with Spherical Wavelet Transform [66] (QBISWT), QBall Imaging in Constant Solid Angle [17] (QBICSA), Nonnegativity Constrained Super-resolved Spherical Deconvolution [27] (CSD) and the Sharpening Deconvolution Transform [29] (SDT).”
MethodInfluentialSelf-citationRamírez-Manzanares, A., Cook, P. A., & Gee, J. C. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-85988-8_37 · Cited by 13
Acceleration of high angular and spatial resolution diffusion imaging using compressed sensing
Mani, M., Jacob, M., Guidon, A., Liu, C., Song, A., Magnotta, V. A., & Zhong, J. (2012) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2012.6235550 · Cited by 9
Self-citationWhite matter structure assessment from reduced HARDI data using low-rank polynomial approximations.
Gur, Y., Jiao, F., Zhu, S. X., & Johnson, C. R. (2012) · PubMed · Cited by 8
Self-citationExtrapolating fiber crossings from DTI data : can we gain the same information as HARDI?
Prčkovska, V., Rodrigues, P., Duits, R., Romeny, B. M. T. H., & Vilanova, A. (2010) · TU/e Research Portal · Cited by 8
Self-citation(1999) · doi:10.1002/1531-8249(199902)45:2<265::aid-ana21>3.0.co;2-3
Wansapura (1999) · doi:10.1002/(sici)1522-2586(199904)9:4
Cited by
Tractography-based connectomes are dominated by false-positive connections
Maier-Hein, K. H., Neher, P., Houde, J.-C., Côté, M.-A., Garyfallidis, E., Zhong, J., Chamberland, M., Yeh, F.-C., Lin, Y.-C., Ji, Q., et al. (2016) · doi:10.1101/084137 · Cited by 1,376
Self-citationAccelerated microstructure imaging via Convex Optimization (AMICO) from diffusion MRI data
Daducci, A., Canales-Rodríguez, E. J., Zhang, H., Dyrby, T. B., Alexander, D. C., & Thiran, J.-P. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.10.026 · Cited by 593
Self-citationDiffusion MRI fiber tractography of the brain
Jeurissen, B., Descoteaux, M., Mori, S., & Leemans, A. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3785 · Cited by 666
“On the same data, however, they are unlikely to outperform fODF tracking approaches.(95,98,99) For a more in‐depth discussion of the dODF in relation to the fiber orientation estimation, the reader is referred to Reference 3.”
BackgroundSelf-citationWhy rankings of biomedical image analysis competitions should be interpreted with care
Maier-Hein, L., Eisenmann, M., Reinke, A., Onogur, S., Stankovic, M., Scholz, P., Arbel, T., Bogunovic, H., Bradley, A. P., Carass, A., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-07619-7 · Cited by 380
Limits to anatomical accuracy of diffusion tractography using modern approaches
Schilling, K. G., Nath, V., Hansen, C., Parvathaneni, P., Blaber, J., Gao, Y., Neher, P., Aydogan, D. B., Shi, Y., Ocampo-Pineda, M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.10.029 · Cited by 260
“Past diffusion MRI challenges have utilized similar frameworks to assess reproducibility of tractography and fiber orientation reconstruction (Daducci et al., 2014).”
BackgroundMethodSelf-citation
Metadata
- Authors
- Daducci, A., Canales-Rodriguez, E. J., Descoteaux, M., Garyfallidis, E., Gur, Y., Lin, Y.-C., Mani, M., Merlet, S., Paquette, M., Ramirez-Manzanares, A., Reisert, M., Rodrigues, P. R., Sepehrband, F., Caruyer, E., Choupan, J., Deriche, R., Jacob, M., Menegaz, G., Prckovska, V., Rivera, M., Wiaux, Y., & Thiran, J.-P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2014-02
- Volume
- 33
- Issue
- 2
- Pages
- 384-399
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2021228864
- Cited by
- 172
- References
- 71
- FWCI
- 10.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.