The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Low-Rank Modeling of Local <formula formulatype="inline"> <tex Notation="TeX">$k$</tex></formula>-Space Neighborhoods (LORAKS) for Constrained MRI
Open accessAbstract
Recent theoretical results on low-rank matrix reconstruction have inspired significant interest in low-rank modeling of MRI images. Existing approaches have focused on higher-dimensional scenarios with data available from multiple channels, timepoints, or image contrasts. The present work demonstrates that single-channel, single-contrast, single-timepoint k-space data can also be mapped to low-rank matrices when the image has limited spatial support or slowly varying phase. Based on this, we develop a novel and flexible framework for constrained image reconstruction that uses low-rank matrix modeling of local k-space neighborhoods (LORAKS). A new regularization penalty and corresponding algorithm for promoting low-rank are also introduced. The potential of LORAKS is demonstrated with simulated and experimental data for a range of denoising and sparse-sampling applications. LORAKS is also compared against state-of-the-art methods like homodyne reconstruction, l1-norm minimization, and total variation minimization, and is demonstrated to have distinct features and advantages. In addition, while calibration-based support and phase constraints are commonly used in existing methods, the LORAKS framework enables calibrationless use of these constraints.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,703
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
The Approximation of One Matrix by Another of Lower Rank
Eckart, C., & Young, G. (1936) · Psychometrika · doi:10.1007/bf02288367 · Cited by 3,800
Guaranteed Minimum-Rank Solutions of Linear Matrix Equations via Nuclear Norm Minimization
Recht, B., Fazel, M., & Parrilo, P. A. (2010) · SIAM Review · doi:10.1137/070697835 · Cited by 3,471
Mean squared error: Love it or leave it? A new look at Signal Fidelity Measures
Wang, Z., & Bovik, A. C. (2009) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.930649 · Cited by 3,175
Hunter, D. R., & Lange, K. (2004) · The American Statistician · doi:10.1198/0003130042836 · Cited by 1,783
SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
Lustig, M., & Pauly, J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22428 · Cited by 822
Low-rank matrix completion using alternating minimization
Jain, P., Netrapalli, P., & Sanghavi, S. (2013) · Proceedings of the forty-fifth annual ACM symposium on Theory of Computing · doi:10.1145/2488608.2488693 · Cited by 817
k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Tsao, J., Boesiger, P., & Pruessmann, K. P. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10611 · Cited by 794
Signal enhancement-a composite property mapping algorithm
CADZOW, J. A. (1988) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/29.1488 · Cited by 701
Accelerated Dynamic MRI Exploiting Sparsity and Low-Rank Structure: k-t SLR
Lingala, S. G., Hu, Y., DiBella, E., & Jacob, M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2100850 · Cited by 664
Homodyne detection in magnetic resonance imaging
Noll, D. C., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.79473 · Cited by 514
Madore, B., Glover, G. H., & Pelc, N. J. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<813::aid-mrm1>3.0.co;2-s · Cited by 433
Calibrationless parallel imaging reconstruction based on structured low-rank matrix completion
Shin, P. J., Larson, P. E. Z., Ohliger, M. A., Elad, M., Pauly, J. M., Vigneron, D. B., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24997 · Cited by 391
SPATIOTEMPORAL IMAGINGWITH PARTIALLY SEPARABLE FUNCTIONS
Liang, Z.-P. (2007) · 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro · doi:10.1109/isbi.2007.357020 · Cited by 369
Partially parallel imaging with localized sensitivities (PILS)
Griswold, M. A., Jakob, P. M., Nittka, M., Goldfarb, J. W., & Haase, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200010)44:4<602::aid-mrm14>3.0.co;2-5 · Cited by 329
Pan, S., & Kak, A. (1983) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1983.1164196 · Cited by 317
Compressed-Sensing MRI With Random Encoding
Haldar, J. P., Hernando, D., & Liang, Z.-P. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2085084 · Cited by 308
Self-citationSingular Value Decomposition (SVD) Image Coding
Andrews, H., & Patterson, C. (1976) · IEEE Transactions on Communications · doi:10.1109/tcom.1976.1093309 · Cited by 304
Lanczos Bidiagonalization With Partial Reorthogonalization
Larsen, R. M. (1998) · DAIMI Report Series · doi:10.7146/dpb.v27i537.7070 · Cited by 304
Zhao, B., Haldar, J. P., Christodoulou, A. G., & Liang, Z.-P. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2203921 · Cited by 295
Self-citationSpatiotemporal Imaging with Partially Separable Functions
Liang, Z.-P. (2007) · 2007 Joint Meeting of the 6th International Symposium on Noninvasive Functional Source Imaging of the Brain and Heart and the International Conference on Functional Biomedical Imaging · doi:10.1109/nfsi-icfbi.2007.4387720 · Cited by 204
Accelerated MR parameter mapping with low‐rank and sparsity constraints
Zhao, B., Lu, W., Hitchens, T. K., Lam, F., Ho, C., & Liang, Z. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25421 · Cited by 188
Rank-Constrained Solutions to Linear Matrix Equations Using PowerFactorization
Haldar, J. P., & Hernando, D. (2009) · IEEE Signal Processing Letters · doi:10.1109/lsp.2009.2018223 · Cited by 156
Self-citationSeparate Magnitude and Phase Regularization via Compressed Sensing
Zhao, F., Noll, D. C., Nielsen, J.-F., & Fessler, J. A. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2196707 · Cited by 131
An algorithm for sparse MRI reconstruction by Schatten p-norm minimization
Majumdar, A., & Ward, R. K. (2010) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2010.09.001 · Cited by 102
Optimal phased-array combination for spectroscopy
Bydder, M., Hamilton, G., Yokoo, T., & Sirlin, C. B. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.01.050 · Cited by 92
Smith, M. R., Nichols, S. T., Henkelman, R. M., & Wood, M. L. (1986) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1986.4307762 · Cited by 85
Denoising diffusion‐weighted magnitude MR images using rank and edge constraints
Lam, F., Babacan, S. D., Haldar, J. P., Weiner, M. W., Schuff, N. W., & Liang, Z. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24728 · Cited by 73
Self-citationParallel reconstruction using null operations
Zhang, J., Liu, C., & Moseley, M. E. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22899 · Cited by 72
Barone, P., & Sebastiani, G. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.141649 · Cited by 35
Improved dynamic MRI reconstruction by exploiting sparsity and rank-deficiency
Majumdar, A. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.10.026 · Cited by 32
Cited by
MoDL: Model-Based Deep Learning Architecture for Inverse Problems
Aggarwal, H. K., Mani, M. P., & Jacob, M. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2865356 · Cited by 1,069
${k}$ -Space Deep Learning for Accelerated MRI
Han, Y., Sunwoo, L., & Ye, J. C. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2927101 · Cited by 344
Image Reconstruction: From Sparsity to Data-Adaptive Methods and Machine Learning
Ravishankar, S., Ye, J. C., & Fessler, J. A. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2936204 · Cited by 294
Metadata
- Authors
- Haldar, J. P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2014-03
- Volume
- 33
- Issue
- 3
- Pages
- 668-681
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2165142794
- Cited by
- 326
- References
- 35
- FWCI
- 9.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.